MRMark Roman

Mark Roman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mark Roman has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Jana Hildreth

    Blaze Science Industries, 4547 West 171st St, Lawndale, CA 90260

    2 shared publications
  • Joseph M Betz

    U.S. National Institutes of Health, Office of Dietary Supplements, 6100 Executive Blvd, Room 3B01, Bethesda, MD 20892

    1 shared publication
  • Silvia Bannister

    Hightower Pharmaceutical Services Corp, 5035 Barrowe Dr, Tampa, FL 33624

    1 shared publication
  • Steven Lunetta

    Pharmavite LLC, 1150 Aviation Pl, San Fernando, CA 91340, USA

    1 shared publication

Latest Publications

  • Determination of Catechins and Caffeine in Camillia sinensis Raw Materials, Extracts, and Dietary Supplements by HPLC-UV: Single-Laboratory Validation

    by Mark C Roman, Jana Hildreth, Silvia Bannister

    A rapid method has been developed to quantify seven catechins and caffeine in green tea (Camillia sinensis) raw material and powdered extract, and dietary supplements containing green tea extract. The method utilizes RP HPLC with a phenyl-based stationary phase and gradient elution. Detection is by UV absorbance. The total run time, including column re-equilibration, is 13 min. Single-laboratory validation (SLV) has been performed on the method to determine the repeatability, accuracy, selectivity, LOD, LOQ, ruggedness, and linearity for (+)-catechin, (–)-epicatechin, (–)-epicatechin gallate, (–)-epigallocatechin, (–)-gallocatechin gallate, (–)-epigallocatechin gallate, and (+)-gallocatechin, as well as caffeine. Repeatability precision and recovery results met AOAC guidelines for SLV studies for all catechins and caffeine down to a level of approximately 20 mg/g. Finished products containing high concentrations of minerals require the use of EDTA to prevent decomposition of the catechins.


  • Open Access

    Determination of Coenzyme Q10 Content in Raw Materials and Dietary Supplements by High-Performance Liquid Chromatography-UV: Collaborative Study

    by Steven Lunetta, Mark Roman

    An international collaborative study was conducted of a high-performance liquid chromatographic (HPLC)-UV method for the determination of coenzyme Q10 (CoQ10, ubidecarenone) in raw materials and dietary supplements. Ten collaborating laboratories determined the total CoQ10 content in 8 blind duplicate samples. Sample materials included CoQ10 raw material and 4 finished product dietary supplements representing softgels, hardshell gelatin capsules, and chewable wafers. In addition, collaborating laboratories received a negative control and negative control spiked with CoQ10 at low and high levels to determine recovery. Materials were extracted with an acetonitriletetrahydrofuranwater mixture. Ferric chloride was added to the test solutions to ensure all CoQ10 was in the oxidized form. The HPLC analyses were performed on a C18 column using UV detection at 275 nm. Repeatability relative standard deviations (RSDr) ranged from 0.94 to 5.05. Reproducibility relative standard deviations (RSDR) ranged from 3.08 to 17.1, with HorRat values ranging from 1.26 to 5.17. Recoveries ranged from 74.0 to 115. Based on these results, the method is recommended for Official First Action for determination of CoQ10 in raw materials and dietary supplement finished products containing CoQ10 at a concentration of >100 mg CoQ10/g test material.


  • Open Access

    Determination of Synephrine in Bitter Orange Raw Materials, Extracts, and Dietary Supplements by Liquid Chromatography with Ultraviolet Detection: Single-Laboratory Validation

    by Mark C Roman, Joseph M Betz, Jana Hildreth

    A method has been developed to quantify synephrine in bitter orange raw material, extracts, and dietary supplements. Single-laboratory validation has been performed on the method to determine the repeatability, accuracy, selectivity, limit of detection/limit of quantification (LOQ), ruggedness, and linearity for p-synephrine and 5 other biogenic amines: octopamine, phenylephrine (m-synephrine), tyramine, N-methyltyramine, and hordenine, which may be present in bitter orange. p-Synephrine was found to be the primary biogenic amine present in all materials tested, accounting for >80 of the total biogenic amine content in all samples except a finished product. Repeatability precision for synephrine was between 1.48 and 3.55 RSD. Synephrine recovery was between 97.5 and 104. The minor alkaloids were typically near the LOQ of the method (300900 g/g) in the test materials, and between-day precision for the minor compounds was poor because interferences could sometimes be mistakenly identified as one of the minor analytes. Recoveries of the minor components ranged from 99.1 to 103 at approximately 6000 g/g spike level, to 90.7 to 120 at 300 g/g spike level.