Vladimir Mitov
Research Subjects
Research Interests
Vladimir Mitov has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Tomislav Kostic
NEMA
10 shared publications Aleksandar Jolić
Medical centre Zaječar, Department for invasive cardiology, Zaječar
6 shared publicationsAleksandar Aleksić
4 shared publicationsDragana Adamović
Medical centre Zaječar, Department for invasive cardiology, Zaječar
4 shared publicationsZoran Perišić
4 shared publicationsAleksandar Aleksic
Medical Center Zaječar, Department of Interventional Cardiology, Zaječar
3 shared publications
Latest Publications
- 1 January 2020
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Srce i krvni sudovi
- Vol. 39 (3) , 91-94
Cardiac complications in patients with COVID-19 infection
COVID 19 infection in three phases: Phase I: Early infection, this phase is characterized with intrusion and direct invasion of COVID 19 into sensitive tissues. In this phase, virus is confronted only by the innate non-specific immunity. Symptoms are moderate in intensity. A more pronounced immune response is taking place, and in some cases a cessation of symptoms occurs. If the infection does not end here, a second phase develops. Phase II: pulmonary phase, pulmonary tissue invasion takes place and leads to direct tissue damage with added pulmonary vasodilation, enhanced endothelial permeability, leucocyte invasion as a cellular immune response to infection. This is clinically represented by further lung damage, and added burden on cardiovascular system. Phase III: Hyperinflammatory phase, this phase is presented as an escalation of immune response, which incorporates ARDS locally, acute myocardial damage, heart failure development, and systemic inflammatory response-multiorgan failure. This is complicated by secondary bacterial infection and enhanced intravascular coagulability. Arrythmia is the most common, but also most benign cardiovascular complication in COVID 19 patients. Viral myocarditis, with heart failure elements, is a complication which has to be always thought of, especially in patients with unusually prolonged dyspnea. COVID 19 infection did not have a direct effect on coronary artery disease incidence, but on the other hand had a major effect on time to first contact of the patients with medical service and to the decision making in the treatment process.
- 1 January 2020
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Srce i krvni sudovi
- Vol. 39 (3) , 91-94
Cardiac complications in patients with COVID-19 infection
COVID 19 infection in three phases: Phase I: Early infection, this phase is characterized with intrusion and direct invasion of COVID 19 into sensitive tissues. In this phase, virus is confronted only by the innate non-specific immunity. Symptoms are moderate in intensity. A more pronounced immune response is taking place, and in some cases a cessation of symptoms occurs. If the infection does not end here, a second phase develops. Phase II: pulmonary phase, pulmonary tissue invasion takes place and leads to direct tissue damage with added pulmonary vasodilation, enhanced endothelial permeability, leucocyte invasion as a cellular immune response to infection. This is clinically represented by further lung damage, and added burden on cardiovascular system. Phase III: Hyperinflammatory phase, this phase is presented as an escalation of immune response, which incorporates ARDS locally, acute myocardial damage, heart failure development, and systemic inflammatory response-multiorgan failure. This is complicated by secondary bacterial infection and enhanced intravascular coagulability. Arrythmia is the most common, but also most benign cardiovascular complication in COVID 19 patients. Viral myocarditis, with heart failure elements, is a complication which has to be always thought of, especially in patients with unusually prolonged dyspnea. COVID 19 infection did not have a direct effect on coronary artery disease incidence, but on the other hand had a major effect on time to first contact of the patients with medical service and to the decision making in the treatment process.
- 1 January 2020
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Srce i krvni sudovi
- Vol. 39 (3) , 111-113
Hyperventilation test as a provocation test in catheterization laboratory
We present a patient in whom hyperventilation test disclosed a culprit lesion on the coronary arteries in the Cath lab. A paient, 41-years of age, was treated at the Department of Invasive Cardiology in Medical center Zajecar due to the newly developed inferolateral STEMI. Coronary angiography revealed mild-to-intermiadate LAD stenosis, OM1 was medially occluded, OM2 branch ostial stenosis of 60%, and right coronary artery was minor, without significant angiographic changes. In the same session, primary percutaneous coronary intervention (PCI) was successfully performed on OM1 with Resolute Integrity 2.5x12 mm stent implanted. Due to repeated anginal pain exercise stress test was performed, which was evaluated as positive, and the stress echocardiographic test confirmed hypokinesia of the apical and medial segments of the inferior and lateral wall. A new coronary angiography showed similar stenoses up to 50% in medial LAD and ostial OM2 have been described, but a new 70% stenosis on first diagonal branch which was treated by PCI by another 2.5x16 mm CRE8 stent implantation. One month after discharge, the patient again complained of chest pain again on moderate exertion, occasionally occurring at rest, and resolving after nitroglycerin. Repeated coronary angiography disclosed the same angiographic findings as earlier without progression or in-stent restenosis, and the operator decided to perform a hyperventilation test for 2 minutes, as an additional test to assess the culprit lesion. Immediately following hyperventilation, the patient complained of chest pain with sweating, accompanied with ECG ST elevation in precordial leads. Control angiography demonstrated TIMI 0 flow at the site of the lesion on the medial segment of the LAD. In the same act, PCI was performed on LAD with implantation of CRE8 3x31 mm stent. The hyperventilation test is a simple diagnostic test that may be useful in some patients during coronary angiography to identify patophysiologic mechanism of myocardial ischemia and “culprit” lesion.
- 1 January 2020
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Srce i krvni sudovi
- Vol. 39 (3) , 111-113
Hyperventilation test as a provocation test in catheterization laboratory
We present a patient in whom hyperventilation test disclosed a culprit lesion on the coronary arteries in the Cath lab. A paient, 41-years of age, was treated at the Department of Invasive Cardiology in Medical center Zajecar due to the newly developed inferolateral STEMI. Coronary angiography revealed mild-to-intermiadate LAD stenosis, OM1 was medially occluded, OM2 branch ostial stenosis of 60%, and right coronary artery was minor, without significant angiographic changes. In the same session, primary percutaneous coronary intervention (PCI) was successfully performed on OM1 with Resolute Integrity 2.5x12 mm stent implanted. Due to repeated anginal pain exercise stress test was performed, which was evaluated as positive, and the stress echocardiographic test confirmed hypokinesia of the apical and medial segments of the inferior and lateral wall. A new coronary angiography showed similar stenoses up to 50% in medial LAD and ostial OM2 have been described, but a new 70% stenosis on first diagonal branch which was treated by PCI by another 2.5x16 mm CRE8 stent implantation. One month after discharge, the patient again complained of chest pain again on moderate exertion, occasionally occurring at rest, and resolving after nitroglycerin. Repeated coronary angiography disclosed the same angiographic findings as earlier without progression or in-stent restenosis, and the operator decided to perform a hyperventilation test for 2 minutes, as an additional test to assess the culprit lesion. Immediately following hyperventilation, the patient complained of chest pain with sweating, accompanied with ECG ST elevation in precordial leads. Control angiography demonstrated TIMI 0 flow at the site of the lesion on the medial segment of the LAD. In the same act, PCI was performed on LAD with implantation of CRE8 3x31 mm stent. The hyperventilation test is a simple diagnostic test that may be useful in some patients during coronary angiography to identify patophysiologic mechanism of myocardial ischemia and “culprit” lesion.
- 1 January 2020
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Srce i krvni sudovi
- Vol. 39 (3) , 114-118
Acute coronary syndrome associated with occlusion of the main trunk of the left coronary artery in patients with a previously negative exercise stress test
Objective. A case report of a patient with acute coronary syndrome with occlusion of the left main coronary artery with a typical clinical picture and a negative exercise stres test result.Case report. A 44-year-old patient is presented to our service as STEMI with elevation in the inferior leads and ST depression in the precordial leads. After intrahospital cardiac arrest and resuscitation, primary PCI of left main coronary artery is performed, after which hemodynamic stabilization occurs. Retrospective review of medical history reveals that he was evaluated three years before the acute event due to occasional chest pain. The pretest probability for coronary heart disease was 38%, so in accordance with the then valid ESC guidelines for stable coronary heart disease, a stress ECG test was performed, which was assessed as negative for significant coronary heart disease. All analyzed test parameters indicated a low risk of adverse cardiovascular events: functional capacity, ST segment denivelation, chronotropic competence, blood pressure variations, Duke treadmill score. With a postest probability of 9%, the patient was not further evaluated for coronary heart disease and was asymptomatic for the next three years and did not respond to follow-up examinations. If he presented himself after 2019 according to the newer ESC guidelines for chronic coronary syndromes, the patient would be indicated to perform a functional imaging test or CT coronary angiography at the time of the initial clinical evaluation.Conclusion. The diagnostic algorithm for patients with chest pain is based on a pretest probability that determines further diagnostic workup. Patients with a negative exercise test and a typical clinical presentation should be referred for further diagnostic imaging test because of the risk that a small number of them may have significant and even critical coronary stenosis.
- 1 January 2020
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Srce i krvni sudovi
- Vol. 39 (3) , 114-118
Acute coronary syndrome associated with occlusion of the main trunk of the left coronary artery in patients with a previously negative exercise stress test
Objective. A case report of a patient with acute coronary syndrome with occlusion of the left main coronary artery with a typical clinical picture and a negative exercise stres test result.Case report. A 44-year-old patient is presented to our service as STEMI with elevation in the inferior leads and ST depression in the precordial leads. After intrahospital cardiac arrest and resuscitation, primary PCI of left main coronary artery is performed, after which hemodynamic stabilization occurs. Retrospective review of medical history reveals that he was evaluated three years before the acute event due to occasional chest pain. The pretest probability for coronary heart disease was 38%, so in accordance with the then valid ESC guidelines for stable coronary heart disease, a stress ECG test was performed, which was assessed as negative for significant coronary heart disease. All analyzed test parameters indicated a low risk of adverse cardiovascular events: functional capacity, ST segment denivelation, chronotropic competence, blood pressure variations, Duke treadmill score. With a postest probability of 9%, the patient was not further evaluated for coronary heart disease and was asymptomatic for the next three years and did not respond to follow-up examinations. If he presented himself after 2019 according to the newer ESC guidelines for chronic coronary syndromes, the patient would be indicated to perform a functional imaging test or CT coronary angiography at the time of the initial clinical evaluation.Conclusion. The diagnostic algorithm for patients with chest pain is based on a pretest probability that determines further diagnostic workup. Patients with a negative exercise test and a typical clinical presentation should be referred for further diagnostic imaging test because of the risk that a small number of them may have significant and even critical coronary stenosis.
- 1 January 2016
- Published by National Library of Serbia in Medicinski Pregled
- Vol. 69 (7-8) , 212-216
The effect of right ventricular pacemaker lead position on functional status in patients with preserved left ventricular ejection fraction
Introduction. The study was aimed at assessing the difference between the right ventricle apex versus the right ventricular outflow tract lead position in functional capacity in the patients with the preserved left ventricular ejection fraction after 12 months of pacemaker stimulation. Material and Methods. This was a prospective, randomized, follow-up study, which lasted for 12 months. The study sample included 132 consecutive patients who were implanted with permanent anti-bradicardiac pacemaker. Regarding the right ventricular lead position the patients were divided into two groups: the right ventricle apex group consisting of 61 patients with right ventricular apex lead position. The right ventricular outflow tract group included 71 patients with right ventricular outflow tract lead position. Functional capacity was assessed by Minnesota Living With Heart Failure score, New York Heart Association class and Six Minute Walk Test. Left ventricular ejection fraction was assessed by echocardiography. Results. Minnesota Living With Heart Failure score and New York Heart Association class had a statistically significant improvement in both study groups. The patients from right ventricle apex group walked 20.95% (p=0.03) more in comparison to starting values. The patients from right ventricular outflow tract group walked only 13.63% (p=0.09) longer distance than the starting one. Conclusion. Analysis of tests of functional status New York Heart Association class and Minnesota Living With Heart Failure questionnaire showed an even improvement in the right ventricle apex and right ventricular outflow tract groups. Analysis of 6 minute walk test showed that only the patients with the preserved left ventricular ejection fraction from the right ventricle apex group had a significant improvement after 12 months of pacemaker stimulation.
- 1 January 2016
- Published by National Library of Serbia in Medicinski Pregled
- Vol. 69 (7-8) , 212-216
The effect of right ventricular pacemaker lead position on functional status in patients with preserved left ventricular ejection fraction
Introduction. The study was aimed at assessing the difference between the right ventricle apex versus the right ventricular outflow tract lead position in functional capacity in the patients with the preserved left ventricular ejection fraction after 12 months of pacemaker stimulation. Material and Methods. This was a prospective, randomized, follow-up study, which lasted for 12 months. The study sample included 132 consecutive patients who were implanted with permanent anti-bradicardiac pacemaker. Regarding the right ventricular lead position the patients were divided into two groups: the right ventricle apex group consisting of 61 patients with right ventricular apex lead position. The right ventricular outflow tract group included 71 patients with right ventricular outflow tract lead position. Functional capacity was assessed by Minnesota Living With Heart Failure score, New York Heart Association class and Six Minute Walk Test. Left ventricular ejection fraction was assessed by echocardiography. Results. Minnesota Living With Heart Failure score and New York Heart Association class had a statistically significant improvement in both study groups. The patients from right ventricle apex group walked 20.95% (p=0.03) more in comparison to starting values. The patients from right ventricular outflow tract group walked only 13.63% (p=0.09) longer distance than the starting one. Conclusion. Analysis of tests of functional status New York Heart Association class and Minnesota Living With Heart Failure questionnaire showed an even improvement in the right ventricle apex and right ventricular outflow tract groups. Analysis of 6 minute walk test showed that only the patients with the preserved left ventricular ejection fraction from the right ventricle apex group had a significant improvement after 12 months of pacemaker stimulation.
- Open Access
- 1 January 2014
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Timocki medicinski glasnik
- Vol. 39 (4) , 205-209
Influence of pacemaker leads position in the right ventricle on left ventricular ejection fraction and volume
The aim of this paper is to assess the influence of RVOT (Right Ventricle Outflow Tract) and RVA (Right Ventricle Apex) position of ventricle pacemaker lead on LVEF and volume, after 12 months of pacemaker stimulation in patients with preserved LVEF. The LVEF was measured with two independent methods, RNV (radionuclide venticulography) and echocardiography. Patients and methodology: this was prospective, randomized follow up study that lasted for 12 months. Our research enveloped 132 consecutive patients implanted with permanent antibradicardiac pacemaker in Zaječar Pacemaker Centre during the period of 2009 to 2011. Regarding the electrode position, all patients were divided into two groups: RVA group with 61 patients with ventricle lead implanted in the right ventricle apex and RVOT group with 71 patients with ventricle lead implanted in right ventricle outflow tract. Results: On study enrollment, there was no group difference in the distribution of gender, age, BMI, VVI to DDD implantation ratio, LVEF, ESV, EDV measured with RNV, and to ESD, EDD, ESV, ESVI measured with echocardiography. After 12 months of pacemaker stimulation, the groups showed no difference in systolic parameters measured with RNV and echo. The only observation was that the ESVI and ESVI measured with echo were slightly elevated on the border of statistical significance only in the RVOT group. Conclusion: Pacemaker stimulation from RVOT or RVA in patients with preserved left ventricle systolic function did not have a negative effect on ejection fraction or left ventricle volumes after 12 months of pacemaker stimulation, measured by two independent noninvasive diagnostic methods.
- 1 January 2014
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Timocki medicinski glasnik
- Vol. 39 (4) , 205-209
Open AccessInfluence of pacemaker leads position in the right ventricle on left ventricular ejection fraction and volume
The aim of this paper is to assess the influence of RVOT (Right Ventricle Outflow Tract) and RVA (Right Ventricle Apex) position of ventricle pacemaker lead on LVEF and volume, after 12 months of pacemaker stimulation in patients with preserved LVEF. The LVEF was measured with two independent methods, RNV (radionuclide venticulography) and echocardiography. Patients and methodology: this was prospective, randomized follow up study that lasted for 12 months. Our research enveloped 132 consecutive patients implanted with permanent antibradicardiac pacemaker in Zaječar Pacemaker Centre during the period of 2009 to 2011. Regarding the electrode position, all patients were divided into two groups: RVA group with 61 patients with ventricle lead implanted in the right ventricle apex and RVOT group with 71 patients with ventricle lead implanted in right ventricle outflow tract. Results: On study enrollment, there was no group difference in the distribution of gender, age, BMI, VVI to DDD implantation ratio, LVEF, ESV, EDV measured with RNV, and to ESD, EDD, ESV, ESVI measured with echocardiography. After 12 months of pacemaker stimulation, the groups showed no difference in systolic parameters measured with RNV and echo. The only observation was that the ESVI and ESVI measured with echo were slightly elevated on the border of statistical significance only in the RVOT group. Conclusion: Pacemaker stimulation from RVOT or RVA in patients with preserved left ventricle systolic function did not have a negative effect on ejection fraction or left ventricle volumes after 12 months of pacemaker stimulation, measured by two independent noninvasive diagnostic methods.
- 15 December 2013
- Published by Medical Faculty, University in Nis in Acta Medica Medianae
- p. 44-47
OVERSENSING AS A CAUSE OF INAPPROPRIATE IMPLANTABLE CARDIOVERTER- DEFIBRILLATOR THERAPY - CASE REPORT
- 15 December 2013
- Published by Medical Faculty, University in Nis in Acta Medica Medianae
- p. 44-47
OVERSENSING AS A CAUSE OF INAPPROPRIATE IMPLANTABLE CARDIOVERTER- DEFIBRILLATOR THERAPY - CASE REPORT
- 20 November 2013
- Vol. 16 (3) , 204-8
The effect of right ventricle pacemaker lead position on diastolic function in patients with preserved left ventricle ejection fraction.
Our aim was to analyze any changes during diastole in patients with normal left ventricular ejection fraction (LVEF), after pacemaker stimulation from the right ventricular outflow tract (RVOT) and right ventricular apex (RVA) lead position. This was a prospective, randomized, follow up study, which lasted for 12 months. Our research included 132 consecutive patients who were implanted with a permanent antibradycardiac pacemaker. Regarding the right ventricle lead position the patients were divided into two groups: The RVOT group--71 patients, with right ventricle outflow tract lead position and the RVA group--61 patients, with right ventricle apex lead position. We measured LVEF and diastolic parameters: peak filling ratio and time to peak filling ratio obtained by radionuclide ventriculography (RNV). The LVEF and various diastolic parameters and left atrial diameter were obtained by echocardiography. Based on the values of deceleration time of early diastolic filling (DTE), and other diastolic parameters like left atrial diameter, all the patients were classified into three degrees of diastolic dysfunction. Our results showed that there was no group difference in distribution of gender, age, body mass index (BMI), VVI to DDD pacemakers implantation ratio, RNV parameters (LVEF, peak filling rate (PFR), time to PFR (TPFR)) and echocardiography parameters: LVEF and parameters of diastolic dysfunction. After 12 months of pacemaker stimulation, LVEF by RNV remained the same in the RVOT group 51.31±15.80% (P=0.75), and also in the RVA group 53.83±6.57%, (P=0.19). In the RVOT group the PFR was highly lower and this finding was significant (P=0.01), while TPFR was also significantly lower (P=0.03). By dividing the patients according to the degree of diastolic dysfunction we found that most patients in both groups at enrollment had a second degree diastolic dysfunction. In both groups diastolic dysfunction increased, the number of patients with third degree diastolic dysfunction increased, and the number of patients with second degree diastolic dysfunction decreased, however, the worsening of diastolic function was significant only in the RVOT group. In conclusion, pacemaker stimulation from RVOT, but not in RVA, leads to progression of diastolic dysfunction in patients with preserved LVEF. This negative effect of pacemaker stimulation from RVOT on diastolic parameters was confirmed by two independent methods, RNV and echocardiography.
- 20 November 2013
- Vol. 16 (3) , 204-8
The effect of right ventricle pacemaker lead position on diastolic function in patients with preserved left ventricle ejection fraction.
Our aim was to analyze any changes during diastole in patients with normal left ventricular ejection fraction (LVEF), after pacemaker stimulation from the right ventricular outflow tract (RVOT) and right ventricular apex (RVA) lead position. This was a prospective, randomized, follow up study, which lasted for 12 months. Our research included 132 consecutive patients who were implanted with a permanent antibradycardiac pacemaker. Regarding the right ventricle lead position the patients were divided into two groups: The RVOT group--71 patients, with right ventricle outflow tract lead position and the RVA group--61 patients, with right ventricle apex lead position. We measured LVEF and diastolic parameters: peak filling ratio and time to peak filling ratio obtained by radionuclide ventriculography (RNV). The LVEF and various diastolic parameters and left atrial diameter were obtained by echocardiography. Based on the values of deceleration time of early diastolic filling (DTE), and other diastolic parameters like left atrial diameter, all the patients were classified into three degrees of diastolic dysfunction. Our results showed that there was no group difference in distribution of gender, age, body mass index (BMI), VVI to DDD pacemakers implantation ratio, RNV parameters (LVEF, peak filling rate (PFR), time to PFR (TPFR)) and echocardiography parameters: LVEF and parameters of diastolic dysfunction. After 12 months of pacemaker stimulation, LVEF by RNV remained the same in the RVOT group 51.31±15.80% (P=0.75), and also in the RVA group 53.83±6.57%, (P=0.19). In the RVOT group the PFR was highly lower and this finding was significant (P=0.01), while TPFR was also significantly lower (P=0.03). By dividing the patients according to the degree of diastolic dysfunction we found that most patients in both groups at enrollment had a second degree diastolic dysfunction. In both groups diastolic dysfunction increased, the number of patients with third degree diastolic dysfunction increased, and the number of patients with second degree diastolic dysfunction decreased, however, the worsening of diastolic function was significant only in the RVOT group. In conclusion, pacemaker stimulation from RVOT, but not in RVA, leads to progression of diastolic dysfunction in patients with preserved LVEF. This negative effect of pacemaker stimulation from RVOT on diastolic parameters was confirmed by two independent methods, RNV and echocardiography.
- 15 June 2013
- Published by Medical Faculty, University in Nis in Acta Medica Medianae
- p. 10-14
RESYNCHRONIZATION THERAPY IN PATIENTS WITH HEART FAILURE
- 15 June 2013
- Published by Medical Faculty, University in Nis in Acta Medica Medianae
- p. 10-14
RESYNCHRONIZATION THERAPY IN PATIENTS WITH HEART FAILURE
- 15 September 2011
- Published by Medical Faculty, University in Nis in Acta Medica Medianae
- p. 54-57
TEMPORARY PACEMAKER LEAD PLACEMENT IN PATIENT WITH PERSISTENT LEFT SUPERIOR VENA CAVA
- 15 September 2011
- Published by Medical Faculty, University in Nis in Acta Medica Medianae
- p. 54-57
TEMPORARY PACEMAKER LEAD PLACEMENT IN PATIENT WITH PERSISTENT LEFT SUPERIOR VENA CAVA
- 15 September 2011
- Published by Medical Faculty, University in Nis in Acta Medica Medianae
- p. 54-57
PLASIRANJE ELEKTRODE PRIVREMENOG PEJSMEJKERA KOD BOLESNIKA SA PERZISTENTNOM LEVOM VENOM CAVOM SUPERIOR
- 15 September 2011
- Published by Medical Faculty, University in Nis in Acta Medica Medianae
- p. 54-57
PLASIRANJE ELEKTRODE PRIVREMENOG PEJSMEJKERA KOD BOLESNIKA SA PERZISTENTNOM LEVOM VENOM CAVOM SUPERIOR