Jorge Muñoz Ledesma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jorge Muñoz Ledesma has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
) Médico
Hospital General Universitario
1 shared publication28007 Madrid
Hospital General Universitario
1 shared publication- Angel Curto- De la Mano
Pediatric Orthopaedic Division, Hospital Universitario 12 de Octubre, Avda. de Córdoba s/n, 28041, Madrid Spain
1 shared publication C Esquerdo
Hospital General Universitario
1 shared publication- Eva Andrés
Unidad Epidemiología Clínica, Hospital 12 de Octubre, CIBER Epidemiología y Salud Pública, Madrid, Spain
1 shared publication Gregorio Marañón Madrid
Hospital General Universitario
1 shared publication
Latest Publications
- Open Access
- 1 August 2012
- Published by SAGE Publications in Journal of Children's Orthopaedics
- Vol. 6 (4) , 285-289
Complications and associated risk factors at screw removal in slipped capital femoral epiphysis treated by cannulated stainless steel screws
Purpose: The aim of our study is to report our complication rate and analyze the associated risk factors when removing cannulated stainless steel screws for SCFE fixation. Methods: This was a multicenter retrospective study of patients who underwent removal of cannulated stainless steel screws after a mean time of 2.03 years of implantation. Thirty-two patients were included (38 hips) with a mean of 13.7 years of age during screw removal surgery. The mean post-removal follow up time was 1.6 years. In all cases the removal of screws was done systematically. Demographic data, possible risk factors related to removal failure, as well as post-removal complications such as post-removal fractures, infections and scar issues were recorded. Results: A removal failure rate of 15.79 % (6/38) was found. The removal surgical time was longer than the initial fixation time but without statistical significance (70.78 vs 61.84 m, p = 0.196). However, the duration of screw implantation ( r2: 7.09; IC: 1.12–13.06) and screw head bony coverage ( r2: 21.32; IC: 5.58–37.06) were both related to this prolonged time. Multivariant analysis revealed that a fully threaded cannulated screw had the lowest removal failure risk (OR: 0.3; IC: 0.14–0.61). There were no postremoval complications recorded. Conclusions: We recommend to use full threaded cannulated stainless steel screws and to perform the procedure as soon as the physis are closed to decrease the surgical time. It is a safe procedure based on a low rate of complications such as post-removal fractures, infection and scar issues.
- 1 August 2012
- Published by SAGE Publications in Journal of Children's Orthopaedics
- Vol. 6 (4) , 285-289
Open AccessComplications and associated risk factors at screw removal in slipped capital femoral epiphysis treated by cannulated stainless steel screws
Purpose: The aim of our study is to report our complication rate and analyze the associated risk factors when removing cannulated stainless steel screws for SCFE fixation. Methods: This was a multicenter retrospective study of patients who underwent removal of cannulated stainless steel screws after a mean time of 2.03 years of implantation. Thirty-two patients were included (38 hips) with a mean of 13.7 years of age during screw removal surgery. The mean post-removal follow up time was 1.6 years. In all cases the removal of screws was done systematically. Demographic data, possible risk factors related to removal failure, as well as post-removal complications such as post-removal fractures, infections and scar issues were recorded. Results: A removal failure rate of 15.79 % (6/38) was found. The removal surgical time was longer than the initial fixation time but without statistical significance (70.78 vs 61.84 m, p = 0.196). However, the duration of screw implantation ( r2: 7.09; IC: 1.12–13.06) and screw head bony coverage ( r2: 21.32; IC: 5.58–37.06) were both related to this prolonged time. Multivariant analysis revealed that a fully threaded cannulated screw had the lowest removal failure risk (OR: 0.3; IC: 0.14–0.61). There were no postremoval complications recorded. Conclusions: We recommend to use full threaded cannulated stainless steel screws and to perform the procedure as soon as the physis are closed to decrease the surgical time. It is a safe procedure based on a low rate of complications such as post-removal fractures, infection and scar issues.
- Open Access
- 1 November 2009
- Published by Georg Thieme Verlag KG in Revista Iberoamericana de Cirugía de la Mano
- Vol. 37 (02) , 133-137
Osteoblastoma del hueso ganchoso. A propósito de un caso
Se presenta el caso de un osteoblastoma recidivante del hueso ganchoso y se revisa el tratamiento de esta lesión. Paciente varón joven con dolor y tumefacción en el dorso de la mano de seis meses de evolución sin respuesta al tratamiento sintomático. A la exploración radiológica se apreció una tumoración lítica del hueso ganchoso, y la RM mostró una tumoración con edema. Por biopsia incisional se diagnóstico que se trataba de un osteoblastoma, por lo que fue intervenido para practicar curetaje intralesional con aporte de esponjosa de cresta ilíaca autóloga. A los seis meses se observó una recidiva local, por lo que fue reintervenido mediante resección en bloque, con resultado final satisfactorio. A case of recurrent osteoblastoma of the hamate is presented in order to review the treatment options. It is selected a case of a young male with hand pain of six months evolution without response to nonoperative treatment. In the X-ray examination it was observed a lytic lesion of the hamate bone and the MRI demonstrated a tumour with oedema involving the hamate. We performed an incisional biopsy to reach the diagnosis of osteoblastoma of the hamate, so we do curettage with bone grafting with autologous iliac crest. Six months after the curettage we observed a local recurrence, so the final treatment applied was the en bloc resection with successful result.
- 1 November 2009
- Published by Georg Thieme Verlag KG in Revista Iberoamericana de Cirugía de la Mano
- Vol. 37 (02) , 133-137
Open AccessOsteoblastoma del hueso ganchoso. A propósito de un caso
Se presenta el caso de un osteoblastoma recidivante del hueso ganchoso y se revisa el tratamiento de esta lesión. Paciente varón joven con dolor y tumefacción en el dorso de la mano de seis meses de evolución sin respuesta al tratamiento sintomático. A la exploración radiológica se apreció una tumoración lítica del hueso ganchoso, y la RM mostró una tumoración con edema. Por biopsia incisional se diagnóstico que se trataba de un osteoblastoma, por lo que fue intervenido para practicar curetaje intralesional con aporte de esponjosa de cresta ilíaca autóloga. A los seis meses se observó una recidiva local, por lo que fue reintervenido mediante resección en bloque, con resultado final satisfactorio. A case of recurrent osteoblastoma of the hamate is presented in order to review the treatment options. It is selected a case of a young male with hand pain of six months evolution without response to nonoperative treatment. In the X-ray examination it was observed a lytic lesion of the hamate bone and the MRI demonstrated a tumour with oedema involving the hamate. We performed an incisional biopsy to reach the diagnosis of osteoblastoma of the hamate, so we do curettage with bone grafting with autologous iliac crest. Six months after the curettage we observed a local recurrence, so the final treatment applied was the en bloc resection with successful result.