JDJeff Darabi

Jeff Darabi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jeff Darabi has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Chuan Guo

    Department of Mechanical Engineering, Southern Illinois University Edwardsville, Edwardsville, IL, 62026, USA

    2 shared publications
  • C. Hale

    Department of Mechanical Engineering, Southern Illinois University Edwardsville , Edwardsville, Illinois 62026, USA

    1 shared publication
  • G. Rojo

    Department of Mechanical Engineering, Southern Illinois University Edwardsville, Edwardsville, IL, USA

    1 shared publication
  • Gerardo Rojo

    1 shared publication
  • Hamed Gholami Derami

    Department of Mechanical Engineering, Southern Illinois University Edwardsville, Edwardsville, USA

    1 shared publication
  • Majid Molki

    Department of Mechanical Engineering, Southern Illinois University Edwardsville, Edwardsville, USA

    1 shared publication

Latest Publications

  • Open Access

    Copper-Carbon Nanotube Micropillars for Passive Thermal Management of High Heat Flux Electronic Devices

    by Gerardo Rojo, Jeff Darabi

    Miniaturization of electronic products and a consequent rapid increase in power density of advanced microprocessors and electronic components have created a need for improved cooling techniques to efficiently remove heat from such devices. Traditional fan-cooled heat sinks have been utilized for several decades as the most cost-effective cooling technique for electronic cooling

  • Advanced Micro-/Nanostructured Wicks for Passive Phase-Change Cooling Systems

    by S. Movaghgharnezhad, J. Darabi

    Heat pipes and vapor chambers have been widely utilized for the thermal management of electronic devices due to their effective heat transport, passive cooling operation, and high reliability. In these devices, a wick structure transports a working fluid from the heat sink to the heat source via capillary action in the wick structure. This paper provides a broad overview of the latest studies on the development of Micro-/Nanostructured wicks for passive cooling systems. Micro/nanopillar-based wick structures provide a high capillary pressure, a large permeability, and larger areas for evaporation, resulting in a significantly higher heat removal capability and dryout heat flux. A special emphasis is placed on the various types and geometries of wick structures and their performance. Additionally, limitations and recommendations for future investigations are discussed.


  • Fabrication and Thermal Characterization of Composite Cu-CNT Micropillars for Capillary-driven Phase-Change Cooling Devices

    by G. Rojo, S. Ghanbari, J. Darabi

    This paper presents the fabrication, testing, and modeling of an array of composite copper-carbon nanotubes (Cu-CNT) micropillars as a wick structure for potential application in passive phase-change cooling systems. This novel wick structure has a larger spacing at the base of the micropillars to provide a higher liquid permeability and mushroom-like structures on the top surface of the micropillars with a smaller spacing to provide a greater capillary pressure. The composite Cu-CNT micropillars were fabricated by an electrochemical deposition method on a patterned copper template. Cauliflower-like nanostructures were then grown on the top surface of the micropillars using chronoamperometry technique to improve the capillary pressure and thermal performance of the wick structure. After successful fabrication of the micropillars, a series of tests were conducted to quantify the thermal performance of the wick structures. The results demonstrate superior thermal and corrosion performances for composite Cu-CNT micropillars compared to those of copper micropillars. Additionally, a thermal resistance network analysis was conducted to model the thermal performance of the fabricated mushroom-shaped micropillar array. Model predictions were compared with the experimental results and good agreement was observed.


  • Continuous isolation of monocytes using a magnetophoretic-based microfluidic Chip

    by Jeff Darabi, Chuan Guo

    Monocytes play an important role in the immune system and are responsible for phagocytizing and degrading foreign microorganisms in the body. The isolation of monocytes is important in various immunological applications such as in-vitro culture of dendritic cells. We present a magnetophoretic-based microfluidic chip for rapid isolation of highly purified, untouched monocytes from human blood by a negative selection method. This bioseparation platform integrates several unique features into a microfluidic device, including locally engineered magnetic field gradients and a continuous flow with a buffer switching scheme to improve the performance of the cell separation process. The results indicate high monocyte purity and recovery performances at a volumetric flow rate that is nearly an order of magnitude larger than comparable microfluidic devices reported in literature. In addition, a comprehensive 2-D computational modeling is performed to determine the cell trajectory and trapping length within the microfluidic chip. Furthermore, the effects of channel height, substrate thickness, cell size, number of beads per cell, and sample flow rate on the cell separation performance are studied.


  • Magnetophoretic-based microfluidic device for DNA isolation

    by C. Hale, J. Darabi

    This paper presents a continuous flow microfluidic device for the separation of DNA from blood using magnetophoresis for biological applications and analysis. This microfluidic bio-separation device has several benefits, including decreased sample handling, smaller sample and reagent volumes, faster isolation time, and decreased cost to perform DNA isolation. One of the key features of this device is the use of short-range magnetic field gradients, generated by a micro-patterned nickel array on the bottom surface of the separation channel. In addition, the device utilizes an array of oppositely oriented, external permanent magnets to produce strong long-range field gradients at the interfaces between magnets, further increasing the effectiveness of the device. A comprehensive simulation is performed using COMSOL Multiphysics to study the effect of various parameters on the magnetic flux within the separation channel. Additionally, a microfluidic device is designed, fabricated, and tested to isolate DNA from blood. The results show that the device has the capability of separating DNA from a blood sample with a purity of 1.8 or higher, a yield of up to 33 μg of polymerase chain reaction ready DNA per milliliter of blood, and a volumetric throughput of up to 50 ml/h.


  • On-chip magnetophoretic isolation of CD4 + T cells from blood

    by Jeff Darabi, Chuan Guo

    This paper presents the design, fabrication, and testing of a magnetophoretic bioseparation chip for the rapid isolation and concentration of CD4 + T cells from the peripheral blood. In a departure from conventional magnetic separation techniques, this microfluidic-based bioseperation device has several unique features, including locally engineered magnetic field gradients and a continuous flow with a buffer switching scheme to improve the performance of the separation process. Additionally, the chip is capable of processing significantly smaller sample volumes than conventional methods and sample losses are eliminated due to decreased handling. Furthermore, the possibility of sample-to-sample contamination is reduced with the disposable format. The overall dimensions of the device were 22 mm by 60 mm by 1 mm, approximately the size of a standard microscope slide. The results indicate a cell purity of greater than 95% at a sample flow rate of 50 ml/h and a cell recovery of 81% at a sample flow rate of 10 ml/h. The cell purity was found to increase with increasing the sample flow rate. However, the cell recovery decreases with an increase in the flow rate. A parametric study was also performed to investigate the effects of channel height, substrate thickness, magnetic bead size, and number of beads per cell on the cell separation performance.