Tun Kuan Yeo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tun Kuan Yeo has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
- Stephen Charn Beng Teoh
National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore
8 shared publications Rupesh Agrawal
National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore
6 shared publicationsKah-Guan Au Eong
Singapore International Eye Cataract Retina Centre, Mount Elizabeth Medical Centre Singapore
4 shared publicationsVictor Menezo
Department of Clinical Ophthalmology, Institute of Ophthalmology, Moorfields Eye Hospital, London, UK
4 shared publications- Achim Langenbucher
Department of Experimental Ophthalmology, Saarland University, Homburg/Saar, Germany
3 shared publications - Bernett Lee
Nanyang Technological University
3 shared publications
Latest Publications
- 11 June 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (10) , 933-935
Deciphering corneal astigmatism - calculation pitfalls and how to avoid them
Options for correcting astigmatism include spectacles or contact lenses, corneal refractive laser surgery or relaxing incisions, toric lenses in the capsular bag, or implantation of supplementary toric lenses in the phakic or pseudophakic eye. This correspondence addresses some of the potential pitfalls which could cause calculation errors when working with astigmatic surfaces and spherocylindrical vergences and gives some advice on avoiding these. To provide some insight, each potential pitfall is illustrated with a clinical example.
- 11 June 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (10) , 933-935
Deciphering corneal astigmatism - calculation pitfalls and how to avoid them
Options for correcting astigmatism include spectacles or contact lenses, corneal refractive laser surgery or relaxing incisions, toric lenses in the capsular bag, or implantation of supplementary toric lenses in the phakic or pseudophakic eye. This correspondence addresses some of the potential pitfalls which could cause calculation errors when working with astigmatic surfaces and spherocylindrical vergences and gives some advice on avoiding these. To provide some insight, each potential pitfall is illustrated with a clinical example.
- Open Access
- 1 January 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 13
Intraocular lens calculation in an eye with intrastromal corneal ring segments for myopia: case report
Introduction: This case report describes the approach and outcomes of intraocular lens (IOL) power calculation methods in a patient with previous intrastromal corneal ring segments (ICRSs) for myopia treatment who underwent cataract surgery. The literature on IOL calculations in eyes undergoing cataract surgery post-ICRS is scarce, with none on ICRS performed for myopia in normal eyes. Patient and Clinical Findings: A 68-year-old man had ICRS implanted bilaterally for myopia correction 27 years ago. He developed visually significant cataracts in both eyes. The measured posterior to anterior corneal radius ratio was found to be low, and average total keratometry values were lower than the average keratometry values bilaterally. These biometric parameters were similar to that of postmyopic laser vision correction (LVC) eyes. Diagnosis, Intervention, and Outcomes: Hence, IOL power calculation was made using the EVO 2.0 postmyopic LVC formula with measured posterior keratometry (PK) using IOLMaster 700. Predicted outcomes of both postmyopic LVC and non-LVC formulas were performed postoperatively. Postmyopic LVC formulas were found to be overall more accurate. Non-LVC formulas tended to have a hyperopic error. Conclusions: Using postmyopic LVC IOL formulas with measured PK may potentially be more accurate for patients with previous ICRS implantations for myopia, and whose eyes have a lower measured posterior to anterior corneal ratio.
- 1 January 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 13
Open AccessIntraocular lens calculation in an eye with intrastromal corneal ring segments for myopia: case report
Introduction: This case report describes the approach and outcomes of intraocular lens (IOL) power calculation methods in a patient with previous intrastromal corneal ring segments (ICRSs) for myopia treatment who underwent cataract surgery. The literature on IOL calculations in eyes undergoing cataract surgery post-ICRS is scarce, with none on ICRS performed for myopia in normal eyes. Patient and Clinical Findings: A 68-year-old man had ICRS implanted bilaterally for myopia correction 27 years ago. He developed visually significant cataracts in both eyes. The measured posterior to anterior corneal radius ratio was found to be low, and average total keratometry values were lower than the average keratometry values bilaterally. These biometric parameters were similar to that of postmyopic laser vision correction (LVC) eyes. Diagnosis, Intervention, and Outcomes: Hence, IOL power calculation was made using the EVO 2.0 postmyopic LVC formula with measured posterior keratometry (PK) using IOLMaster 700. Predicted outcomes of both postmyopic LVC and non-LVC formulas were performed postoperatively. Postmyopic LVC formulas were found to be overall more accurate. Non-LVC formulas tended to have a hyperopic error. Conclusions: Using postmyopic LVC IOL formulas with measured PK may potentially be more accurate for patients with previous ICRS implantations for myopia, and whose eyes have a lower measured posterior to anterior corneal ratio.
- Open Access
- 4 May 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 266, 26-36
Accuracy of Toric Intraocular Lens Formulas With Measured Posterior Corneal Astigmatism of Different Orientations
- 4 May 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 266, 26-36
Open AccessAccuracy of Toric Intraocular Lens Formulas With Measured Posterior Corneal Astigmatism of Different Orientations
- Open Access
- 11 January 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 261, 7-18
The Influence of Lens Position, Vault Prediction, and Posterior Cornea on Phakic Posterior Chamber Intraocular Lens Power
- 11 January 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 261, 7-18
Open AccessThe Influence of Lens Position, Vault Prediction, and Posterior Cornea on Phakic Posterior Chamber Intraocular Lens Power
- Open Access
- 12 December 2023
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 260, 102-114
Differences Between Keratometry and Total Keratometry Measurements in a Large Dataset Obtained With a Modern Swept Source Optical Coherence Tomography Biometer
- 12 December 2023
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 260, 102-114
Open AccessDifferences Between Keratometry and Total Keratometry Measurements in a Large Dataset Obtained With a Modern Swept Source Optical Coherence Tomography Biometer
- 1 June 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (6) , 556-557
Surgeons need to know more about intraocular lens design for accurate power calculation
Improvement in biometry and formulas has raised the bar for accurate intraocular lens (IOL) power calculation. However, when we look closely at the performance of a specific IOL model, we often find that the prediction error varies with the implant power. This phenomenon has no explanation other than that the optic design of the IOL has shifted over the power range, thereby disrupting the assumptions of the calculations. By this report, we call the industry to be more transparent and disclose the basic information about the IOL design that is important for accurate IOL power calculation. The relevant information concerns the refractive index, the central optic thickness, the anterior and posterior curvature radii, the toricity location, the spherical aberration, and haptic angulation. The goal is to predict possible shifts in principal planes or IOL position over the power range causing a refractive surprise if not corrected for.
- 1 June 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (6) , 556-557
Surgeons need to know more about intraocular lens design for accurate power calculation
Improvement in biometry and formulas has raised the bar for accurate intraocular lens (IOL) power calculation. However, when we look closely at the performance of a specific IOL model, we often find that the prediction error varies with the implant power. This phenomenon has no explanation other than that the optic design of the IOL has shifted over the power range, thereby disrupting the assumptions of the calculations. By this report, we call the industry to be more transparent and disclose the basic information about the IOL design that is important for accurate IOL power calculation. The relevant information concerns the refractive index, the central optic thickness, the anterior and posterior curvature radii, the toricity location, the spherical aberration, and haptic angulation. The goal is to predict possible shifts in principal planes or IOL position over the power range causing a refractive surprise if not corrected for.
- Open Access
- 4 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (2) , 400
iERM: An Interpretable Deep Learning System to Classify Epiretinal Membrane for Different Optical Coherence Tomography Devices: A Multi-Center Analysis
Background: Epiretinal membranes (ERM) have been found to be common among individuals >50 years old. However, the severity grading assessment for ERM based on optical coherence tomography (OCT) images has remained a challenge due to lacking reliable and interpretable analysis methods. Thus, this study aimed to develop a two-stage deep learning (DL) system named iERM to provide accurate automatic grading of ERM for clinical practice. Methods: The iERM was trained based on human segmentation of key features to improve classification performance and simultaneously provide interpretability to the classification results. We developed and tested iERM using a total of 4547 OCT B-Scans of four different commercial OCT devices that were collected from nine international medical centers. Results: As per the results, the integrated network effectively improved the grading performance by 1–5.9% compared with the traditional classification DL model and achieved high accuracy scores of 82.9%, 87.0%, and 79.4% in the internal test dataset and two external test datasets, respectively. This is comparable to retinal specialists whose average accuracy scores are 87.8% and 79.4% in two external test datasets. Conclusion: This study proved to be a benchmark method to improve the performance and enhance the interpretability of the traditional DL model with the implementation of segmentation based on prior human knowledge. It may have the potential to provide precise guidance for ERM diagnosis and treatment.
- 4 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (2) , 400
Open AccessiERM: An Interpretable Deep Learning System to Classify Epiretinal Membrane for Different Optical Coherence Tomography Devices: A Multi-Center Analysis
Background: Epiretinal membranes (ERM) have been found to be common among individuals >50 years old. However, the severity grading assessment for ERM based on optical coherence tomography (OCT) images has remained a challenge due to lacking reliable and interpretable analysis methods. Thus, this study aimed to develop a two-stage deep learning (DL) system named iERM to provide accurate automatic grading of ERM for clinical practice. Methods: The iERM was trained based on human segmentation of key features to improve classification performance and simultaneously provide interpretability to the classification results. We developed and tested iERM using a total of 4547 OCT B-Scans of four different commercial OCT devices that were collected from nine international medical centers. Results: As per the results, the integrated network effectively improved the grading performance by 1–5.9% compared with the traditional classification DL model and achieved high accuracy scores of 82.9%, 87.0%, and 79.4% in the internal test dataset and two external test datasets, respectively. This is comparable to retinal specialists whose average accuracy scores are 87.8% and 79.4% in two external test datasets. Conclusion: This study proved to be a benchmark method to improve the performance and enhance the interpretability of the traditional DL model with the implementation of segmentation based on prior human knowledge. It may have the potential to provide precise guidance for ERM diagnosis and treatment.
- 1 December 2020
- Published by Elsevier in Ophthalmology
- Vol. 127 (12) , E112-E113
Re: Kane et al.: A comparison of the accuracy of 6 modern toric intraocular lens formulas (Ophthalmology. 2020;127:1472-1486)
- 1 December 2020
- Published by Elsevier in Ophthalmology
- Vol. 127 (12) , E112-E113
Re: Kane et al.: A comparison of the accuracy of 6 modern toric intraocular lens formulas (Ophthalmology. 2020;127:1472-1486)
- Open Access
- 31 August 2020
- Published by Springer Nature in Eye
- Vol. 35 (6) , 1705-1711
Accuracy of intraocular lens formulas using total keratometry in eyes with previous myopic laser refractive surgery
Objectives: This comparative study aimed to determine if total keratometry (TK) from IOLMaster 700 could be applied to conventional formulas to perform IOL power calculation in eyes with previous myopic laser refractive surgery, and to evaluate their accuracy with known post-laser refractive surgery formulas. Methods: Sixty-four eyes of 49 patients with previous myopic laser refractive surgery were evaluated 1 month after cataract surgery. A comparison of the prediction error was made between no clinical history post-laser refractive surgery formulas (Barrett True-K, Haigis-L, Shammas-PL) and conventional formulas (EVO, Haigis, Hoffer Q, Holladay I, and SRK/T) using TK values obtained with the optical biometer IOLMaster 700 (Carl Zeiss Meditec), as well as Barrett True-K with TK. Results: The mean prediction error was statistically different from zero for Barrett True-K, Barrett True-K with TK, Haigis-L, Shammas-PL, and Holladay I with TK. The mean absolute error (MAE) was 0.424, 0.671, 0.638, 0.439, 0.408, 0.424, 0.479, 0.647, and 0.524, and median absolute error (MedAE) was 0.388, 0.586, 0.605, 0.298, 0.294, 0.324, 0.333, 0.438, and 0.377 for Barrett True-K, Haigis-L, Shammas-PL, Barrett True-K TK, EVO with TK, Haigis with TK, Hoffer Q with TK, Holladay I with TK, and SRK/T with TK, respectively. EVO TK followed by Barrett True-K TK and Haigis TK achieved the highest percentages of patients with absolute prediction error within 0.50 and 1.00 D (68.75%, 92.19%, and 64.06%, 92.19%, respectively) Conclusions: Formulas combined with TK achieve similar or better results compared to existing no-history post-myopic laser refractive surgery formulas.
- 31 August 2020
- Published by Springer Nature in Eye
- Vol. 35 (6) , 1705-1711
Open AccessAccuracy of intraocular lens formulas using total keratometry in eyes with previous myopic laser refractive surgery
Objectives: This comparative study aimed to determine if total keratometry (TK) from IOLMaster 700 could be applied to conventional formulas to perform IOL power calculation in eyes with previous myopic laser refractive surgery, and to evaluate their accuracy with known post-laser refractive surgery formulas. Methods: Sixty-four eyes of 49 patients with previous myopic laser refractive surgery were evaluated 1 month after cataract surgery. A comparison of the prediction error was made between no clinical history post-laser refractive surgery formulas (Barrett True-K, Haigis-L, Shammas-PL) and conventional formulas (EVO, Haigis, Hoffer Q, Holladay I, and SRK/T) using TK values obtained with the optical biometer IOLMaster 700 (Carl Zeiss Meditec), as well as Barrett True-K with TK. Results: The mean prediction error was statistically different from zero for Barrett True-K, Barrett True-K with TK, Haigis-L, Shammas-PL, and Holladay I with TK. The mean absolute error (MAE) was 0.424, 0.671, 0.638, 0.439, 0.408, 0.424, 0.479, 0.647, and 0.524, and median absolute error (MedAE) was 0.388, 0.586, 0.605, 0.298, 0.294, 0.324, 0.333, 0.438, and 0.377 for Barrett True-K, Haigis-L, Shammas-PL, Barrett True-K TK, EVO with TK, Haigis with TK, Hoffer Q with TK, Holladay I with TK, and SRK/T with TK, respectively. EVO TK followed by Barrett True-K TK and Haigis TK achieved the highest percentages of patients with absolute prediction error within 0.50 and 1.00 D (68.75%, 92.19%, and 64.06%, 92.19%, respectively) Conclusions: Formulas combined with TK achieve similar or better results compared to existing no-history post-myopic laser refractive surgery formulas.
- 1 March 2018
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 34 (3) , 150-155
Evaluation of the Accuracy of Two Marking Methods and the Novel toriCAM Application for Toric Intraocular Lens Alignment
PURPOSE: To compare the accuracy of two common reference marking methods for toric intraocular lens alignment before and after using the novel toriCAM application. METHODS: In this prospective, randomized study, 22 participants were randomly allocated to two groups, either freehand or slit-lamp–assisted marking. Corneal markings at 0° and 180° were made using either method. The toriCAM application on a smartphone was then used to assess the rotational alignment of these markings and compared to the actual alignment as measured by the Zaldivar calipers on the iTrace Topographer (Tracey Technologies, Houston, TX) as a reference. The errors in marking with and without using the application were analyzed for all patients in each cohort and determined for each marking method. RESULTS: Twenty eyes of 11 patients were marked using the freehand method and 20 eyes of the other 11 patients were marked using the slit-lamp method. The mean absolute error of all markings before toriCAM adjustment was 3.18° ± 2.22°. This was significantly reduced to 1.28° ± 1.34° after using the application ( P < .001). This improvement was also noted separately in the freehand and slit-lamp groups. Comparison of the freehand and slit-lamp methods did not show any statistically significant difference in accuracy at both time points. CONCLUSIONS: The novel toriCAM application is able to significantly improve the accuracy of reference marking for both freehand and slit-lamp methods. [ J Refract Surg. 2018;34(3):150–155.]
- 1 March 2018
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 34 (3) , 150-155
Evaluation of the Accuracy of Two Marking Methods and the Novel toriCAM Application for Toric Intraocular Lens Alignment
PURPOSE: To compare the accuracy of two common reference marking methods for toric intraocular lens alignment before and after using the novel toriCAM application. METHODS: In this prospective, randomized study, 22 participants were randomly allocated to two groups, either freehand or slit-lamp–assisted marking. Corneal markings at 0° and 180° were made using either method. The toriCAM application on a smartphone was then used to assess the rotational alignment of these markings and compared to the actual alignment as measured by the Zaldivar calipers on the iTrace Topographer (Tracey Technologies, Houston, TX) as a reference. The errors in marking with and without using the application were analyzed for all patients in each cohort and determined for each marking method. RESULTS: Twenty eyes of 11 patients were marked using the freehand method and 20 eyes of the other 11 patients were marked using the slit-lamp method. The mean absolute error of all markings before toriCAM adjustment was 3.18° ± 2.22°. This was significantly reduced to 1.28° ± 1.34° after using the application ( P < .001). This improvement was also noted separately in the freehand and slit-lamp groups. Comparison of the freehand and slit-lamp methods did not show any statistically significant difference in accuracy at both time points. CONCLUSIONS: The novel toriCAM application is able to significantly improve the accuracy of reference marking for both freehand and slit-lamp methods. [ J Refract Surg. 2018;34(3):150–155.]