Seigo Okawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Seigo Okawa has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Kouichi Watanabe
Division of Biomaterial Science, Department of Oral Health Science, Niigata University Graduate School of Medical and Dental Sciences
6 shared publicationsMitsugu Kanatani
Division of Biomaterial Science, Department of Oral Health Science, Niigata University Graduate School of Medical and Dental Sciences
4 shared publicationsOsamu Miyakawa
Division of Dental Biomaterial Science, Niigata University Graduate School of Medical and Dental Sciences
3 shared publications- Norimasa Taka
Division of Preventive Dentistry, Faculty of Dentistry, Graduate School of Medical and Dental Sciences, Niigata University, 2-5274 Gakkocho-dori, Chuo-ku, Niigata 951-8514, Japan
2 shared publications Syuji Nakano
2 shared publications- Yujin Aoyagi
Division of Bio-Prosthodontics, Faculty of Dentistry, Graduate School of Medical and Dental Sciences, Niigata University, 2-5274 Gakkocho-dori, Chuo-ku, Niigata 951-8514, Japan
2 shared publications
Latest Publications
- Open Access
- 1 May 2020
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 11 (2) , 27
Effect of Modification with Helium Atmospheric-Pressure Plasma and Deep-Ultraviolet Light on Adhesive Shear Strength of Fiber-Reinforced Poly(ether-ether-ketone) Polymer
We investigated the effect of helium atmospheric-pressure plasma (PL) and deep-ultraviolet (UV) light treatments on the adhesive properties of fiber-reinforced poly(ether-ether-ketone) polymer (PEEK). PEEK disks reinforced with carbon (CPEEK) or glass (GPEEK) fibers were polished, modified with PL and UV for 60 s, and the surface energy was calculated by measuring the contact angles. The disk surfaces were analyzed by X-ray photoemission spectroscopy. Shear bond strength testing was performed using a universal testing machine, and the fracture surfaces were observed by electron probe microanalyzer. Data were analyzed with one and two-way ANOVA and Tukey’s post-hoc test (p < 0.05). The surface energies were increased by the modifications, which created OH functional groups on the surfaces. The bond strengths of CPEEK were increased by PL, and those of GPEEK were increased by PL and UV, owing to chemical bonding at the interface.
- 1 May 2020
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 11 (2) , 27
Open AccessEffect of Modification with Helium Atmospheric-Pressure Plasma and Deep-Ultraviolet Light on Adhesive Shear Strength of Fiber-Reinforced Poly(ether-ether-ketone) Polymer
We investigated the effect of helium atmospheric-pressure plasma (PL) and deep-ultraviolet (UV) light treatments on the adhesive properties of fiber-reinforced poly(ether-ether-ketone) polymer (PEEK). PEEK disks reinforced with carbon (CPEEK) or glass (GPEEK) fibers were polished, modified with PL and UV for 60 s, and the surface energy was calculated by measuring the contact angles. The disk surfaces were analyzed by X-ray photoemission spectroscopy. Shear bond strength testing was performed using a universal testing machine, and the fracture surfaces were observed by electron probe microanalyzer. Data were analyzed with one and two-way ANOVA and Tukey’s post-hoc test (p < 0.05). The surface energies were increased by the modifications, which created OH functional groups on the surfaces. The bond strengths of CPEEK were increased by PL, and those of GPEEK were increased by PL and UV, owing to chemical bonding at the interface.
- Open Access
- 12 March 2020
- Published by MDPI AG in Preprints.org
Adhesive Properties of Fiber-Reinforced Poly(Ether-Ether-Ketone)Polymer Modified with Helium Atmospheric-Pressure Plasma and Deep-Ultraviolet Light
We investigated the effect of helium atmospheric-pressure plasma (PL) and deep-ultraviolet (UV) light treatments on the adhesive properties of fiber-reinforced poly(ether-ether-ketone)polymer (PEEK). PEEK disks reinforced with carbon (CPEEK) or glass (GPEEK) fibers were polished, modified with PL and UV for 60 s, and the surface energy was calculated by measuring the contact angles. The disk surfaces were analyzed by X-ray photoemission spectroscopy. Shear bond strength testing was performed using a universal testing machine, and the fracture surfaces were observed by electron probe microanalyzer. Data were analyzed with one and two-way ANOVA and Tukey’s post-hoc test (p < 0.05). The surface energies were increased by the modifications, which created OH functional groups on the surfaces. The bond strengths of CPEEK were increased by PL and those of GPEEK were increased by PL and UV, owing to chemical bonding at the interface.
- 12 March 2020
- Published by MDPI AG in Preprints.org
Open AccessAdhesive Properties of Fiber-Reinforced Poly(Ether-Ether-Ketone)Polymer Modified with Helium Atmospheric-Pressure Plasma and Deep-Ultraviolet Light
We investigated the effect of helium atmospheric-pressure plasma (PL) and deep-ultraviolet (UV) light treatments on the adhesive properties of fiber-reinforced poly(ether-ether-ketone)polymer (PEEK). PEEK disks reinforced with carbon (CPEEK) or glass (GPEEK) fibers were polished, modified with PL and UV for 60 s, and the surface energy was calculated by measuring the contact angles. The disk surfaces were analyzed by X-ray photoemission spectroscopy. Shear bond strength testing was performed using a universal testing machine, and the fracture surfaces were observed by electron probe microanalyzer. Data were analyzed with one and two-way ANOVA and Tukey’s post-hoc test (p < 0.05). The surface energies were increased by the modifications, which created OH functional groups on the surfaces. The bond strengths of CPEEK were increased by PL and those of GPEEK were increased by PL and UV, owing to chemical bonding at the interface.
- 1 January 2013
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 32 (2) , 281-288
Calcium phosphates deposited on titanium electrode surface —Part 1: Effect of the electrode polarity and oxide film on the deposited materials
We report experimental results about the effect of polarity of electrode and anodized titanium oxide film on the deposited materials by electrolysis of an acidic calcium phosphate solution. Mirror-polished titanium and anodized titanium were used as anode or cathode, and a Pt plate was used as a counter electrode. The load voltage was held constant at 20 VDC. No deposited materials were found on the anode surface. On the other hand, dicalcium phosphate dihydrate (DCPD) was deposited on the cathode surface at the beginning of the electrolysis. After the electrolysis time 600 s, the non-stoichiometric hydroxyapatite (HAp) with several hundred nanometers was formed on the specimen surface. Based on X-ray photoelectron spectroscopy data, the anodized oxide film contained both P5+ and P3+ ions. This characteristic of the oxide film and the electrolysis conditions were related to the behavior of the deposition of ultra fine HAp with high crystallinity.
- 1 January 2013
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 32 (2) , 281-288
Calcium phosphates deposited on titanium electrode surface —Part 1: Effect of the electrode polarity and oxide film on the deposited materials
We report experimental results about the effect of polarity of electrode and anodized titanium oxide film on the deposited materials by electrolysis of an acidic calcium phosphate solution. Mirror-polished titanium and anodized titanium were used as anode or cathode, and a Pt plate was used as a counter electrode. The load voltage was held constant at 20 VDC. No deposited materials were found on the anode surface. On the other hand, dicalcium phosphate dihydrate (DCPD) was deposited on the cathode surface at the beginning of the electrolysis. After the electrolysis time 600 s, the non-stoichiometric hydroxyapatite (HAp) with several hundred nanometers was formed on the specimen surface. Based on X-ray photoelectron spectroscopy data, the anodized oxide film contained both P5+ and P3+ ions. This characteristic of the oxide film and the electrolysis conditions were related to the behavior of the deposition of ultra fine HAp with high crystallinity.
- Open Access
- 1 January 2009
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 28 (1) , 68-74
Chemical mechanical polishing of titanium with colloidal silica containing hydrogen peroxide-mirror polishing and surface properties
Chemical mechanical polishing (CMP) of cpTi (Ti) was carried out using two types of slurries, acidic and basic colloidal silica containing H2O2 up to 3 wt%, to obtain flat and mirror-polished surfaces without any contaminated and reacted layers. Polishing behavior and surface properties were investigated using AFM, EPMA, and XPS. Weight loss of Ti polished by CMP using the basic slurry was larger than that using the acidic one, and surface roughness was less than 2 nm RMS when basic slurry containing 3 wt% H2O2 was used. Moreover, three kinds of chemical species, OH-, O2-, and H2O, were detected on the Ti surfaces polished by CMP using these slurries. Results of this study showed that CMP using colloidal silica containing H2O2 successfully created a mirror-polished surface without contaminated and reacted layers.
- 1 January 2009
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 28 (1) , 68-74
Open AccessChemical mechanical polishing of titanium with colloidal silica containing hydrogen peroxide-mirror polishing and surface properties
Chemical mechanical polishing (CMP) of cpTi (Ti) was carried out using two types of slurries, acidic and basic colloidal silica containing H2O2 up to 3 wt%, to obtain flat and mirror-polished surfaces without any contaminated and reacted layers. Polishing behavior and surface properties were investigated using AFM, EPMA, and XPS. Weight loss of Ti polished by CMP using the basic slurry was larger than that using the acidic one, and surface roughness was less than 2 nm RMS when basic slurry containing 3 wt% H2O2 was used. Moreover, three kinds of chemical species, OH-, O2-, and H2O, were detected on the Ti surfaces polished by CMP using these slurries. Results of this study showed that CMP using colloidal silica containing H2O2 successfully created a mirror-polished surface without contaminated and reacted layers.
- 1 January 2009
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 28 (4) , 513-518
Characterization of calcium phosphate deposited on valve metal by anodic oxidation with polarity inversion
Electrochemical deposition of calcium phosphate (CAP) on valve metals such as Ta, Nb, and Zr, was performed by anodic oxidation with alternate polarity inversion at an applied 20 VDC. A saturated hydroxyapatite(HAP)-phosphoric acid solution (pH 3) was used as the electrolyte. FTIR, XRD, and XPS were employed to investigate the detailed characteristics of the deposition. HAP was precipitated on Ta; HAP including brushite and monetite on Nb; and HAP and monetite on Zr. The Ca/P atomic ratios were 1.3-1.5 by XPS, and HPO42– bands were detected on Ta by FTIR. Therefore, the HAP precipitated on Ta was a Ca-deficient HAP. In addition, the XPS spectra of the specimens showed that phosphate ions were incorporated into the anodic oxide film. Deposits with nano-grain size were observed by AFM. The results confirmed that CAP with nano-grain size was deposited on valve metals by the anodic oxidation with polarity inversion.
- 1 January 2009
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 28 (4) , 513-518
Characterization of calcium phosphate deposited on valve metal by anodic oxidation with polarity inversion
Electrochemical deposition of calcium phosphate (CAP) on valve metals such as Ta, Nb, and Zr, was performed by anodic oxidation with alternate polarity inversion at an applied 20 VDC. A saturated hydroxyapatite(HAP)-phosphoric acid solution (pH 3) was used as the electrolyte. FTIR, XRD, and XPS were employed to investigate the detailed characteristics of the deposition. HAP was precipitated on Ta; HAP including brushite and monetite on Nb; and HAP and monetite on Zr. The Ca/P atomic ratios were 1.3-1.5 by XPS, and HPO42– bands were detected on Ta by FTIR. Therefore, the HAP precipitated on Ta was a Ca-deficient HAP. In addition, the XPS spectra of the specimens showed that phosphate ions were incorporated into the anodic oxide film. Deposits with nano-grain size were observed by AFM. The results confirmed that CAP with nano-grain size was deposited on valve metals by the anodic oxidation with polarity inversion.
- 1 January 2004
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 23 (4) , 504-511
Surface Properties of Electrochemically Buffed Titanium Casting
Electrochemical buffing, a combined process of electrochemical and mechanical polishing, was applied to titanium casting. Mixture of α-Al2O3 suspension (average grain diameter of 5μm) and 5% KNO3 solution was used as abrasive slurry. Specimen and experimental wheel buff were respectively connected to the positive and negative poles of a DC source, whose potential ratings ranged from 0V (MEP) to 10V (ECB10). Surface roughness, hardness, color, and cleanness were investigated. ECB10 surface produced a gold color and attained a mirror finish, as its roughness value was only one-quarter that of MEP. High amount of aluminum was present in MEP surface. Its bond state entirely differed from that of α-Al2O3, hence indicating surface alteration due to chemical reactions with the abrasive material. At higher potentials, reaction products might be dissolved anodically, so that the surface was chemically clean to some extent. The surface also became rich in OH-.
- 1 January 2004
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 23 (4) , 504-511
Surface Properties of Electrochemically Buffed Titanium Casting
Electrochemical buffing, a combined process of electrochemical and mechanical polishing, was applied to titanium casting. Mixture of α-Al2O3 suspension (average grain diameter of 5μm) and 5% KNO3 solution was used as abrasive slurry. Specimen and experimental wheel buff were respectively connected to the positive and negative poles of a DC source, whose potential ratings ranged from 0V (MEP) to 10V (ECB10). Surface roughness, hardness, color, and cleanness were investigated. ECB10 surface produced a gold color and attained a mirror finish, as its roughness value was only one-quarter that of MEP. High amount of aluminum was present in MEP surface. Its bond state entirely differed from that of α-Al2O3, hence indicating surface alteration due to chemical reactions with the abrasive material. At higher potentials, reaction products might be dissolved anodically, so that the surface was chemically clean to some extent. The surface also became rich in OH-.
- 1 January 1996
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 15 (2) , 212-219,254
Possible Segregation Caused by Centrifugal Titanium Casting
The possibility of the segregation under solidification process using a centrifugal casting machine was investigated using an electron probe microanalyzer with elemental distribution map, line analysis and quantitative analysis. When a very small quantity of platinum was added to local molten titanium during the casting process, macroscopic segregation was observed under conditions of density difference of 0.1 g/cm3 at the most, confirming that the centrifugal force of the casting machine is extremely strong. When a Ti-6Al-4V alloy was cast, however, no macroscopic segregation was observed. The centrifugal force of the casting machine examined in the present study hardly results in the body-force segregation in this titanium alloy.
- 1 January 1996
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 15 (2) , 212-219,254
Possible Segregation Caused by Centrifugal Titanium Casting
The possibility of the segregation under solidification process using a centrifugal casting machine was investigated using an electron probe microanalyzer with elemental distribution map, line analysis and quantitative analysis. When a very small quantity of platinum was added to local molten titanium during the casting process, macroscopic segregation was observed under conditions of density difference of 0.1 g/cm3 at the most, confirming that the centrifugal force of the casting machine is extremely strong. When a Ti-6Al-4V alloy was cast, however, no macroscopic segregation was observed. The centrifugal force of the casting machine examined in the present study hardly results in the body-force segregation in this titanium alloy.