Liu-Yi Ling
Research Subjects
Research Interests
Liu-Yi Ling has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Min Qin
Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, China
5 shared publications - Cong-Lei Ye
Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China
4 shared publications - Pinhua Xie
Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, China
4 shared publications Ren-Zhi Hu
3 shared publicationsNi-Na Zheng
2 shared publicationsAng Li
1 shared publication
Latest Publications
- 1 October 2014
- Vol. 34 (10) , 2845-50
[Fast and accurate extraction of ring-down time in cavity ring-down spectroscopy].
Research is conducted to accurate and efficient algorithms for extracting ring-down time (r) in cavity ring-down spectroscopy (CRDS) which is used to measure NO3 radical in the atmosphere. Fast and accurate extraction of ring-down time guarantees more precise and higher speed of measurement. In this research, five kinds of commonly used algorithms are selected to extract ring-down time which respectively are fast Fourier transform (FFT) algorithm, discrete Fourier transform (DFT) algorithm, linear regression of the sum (LRS) algorithm, Levenberg-Marquardt (LM) algorithm and least squares (LS) algorithm. Simulated ring-down signals with various amplitude levels of white noises are fitted by using five kinds of the above-mentioned algorithms, and comparison and analysis is conducted to the fitting results of five kinds of algorithms from four respects: the vulnerability to noises, the accuracy and precision of the fitting, the speed of the fitting and preferable fitting ring-down signal waveform length The research results show that Levenberg-Marquardt algorithm and linear regression of the sum algorithm are able to provide more precise results and prove to have higher noises immunity, and by comparison, the fitting speed of Leven- berg-Marquardt algorithm turns out to be slower. In addition, by analysis of simulated ring-down signals, five to ten times of ring-down time is selected to be the best fitting waveform length because in this case, standard deviation of fitting results of five kinds of algorithms proves to be the minimum. External modulation diode laser and cavity which consists of two high reflectivity mirrors are used to construct a cavity ring-down spectroscopy detection system. According to our experimental conditions, in which the noise level is 0.2%, linear regression of the sum algorithm and Levenberg-Marquardt algorithm are selected to process experimental data. The experimental results show that the accuracy and precision of linear regression of the sum algorithm is considerably close to those of Levenberg-Marquardt algorithm, and on the other hand, the fitting speed of linear regression of the sum algorithm is faster than that of Levenberg-Marquardt algorithm about five times. The experimental results are consistent with the simulation analysis, and it indicates that linear regression of the sum algorithm is the desirable fitting method, as far as our experimental conditions are concerned.
- 1 October 2014
- Vol. 34 (10) , 2845-50
[Fast and accurate extraction of ring-down time in cavity ring-down spectroscopy].
Research is conducted to accurate and efficient algorithms for extracting ring-down time (r) in cavity ring-down spectroscopy (CRDS) which is used to measure NO3 radical in the atmosphere. Fast and accurate extraction of ring-down time guarantees more precise and higher speed of measurement. In this research, five kinds of commonly used algorithms are selected to extract ring-down time which respectively are fast Fourier transform (FFT) algorithm, discrete Fourier transform (DFT) algorithm, linear regression of the sum (LRS) algorithm, Levenberg-Marquardt (LM) algorithm and least squares (LS) algorithm. Simulated ring-down signals with various amplitude levels of white noises are fitted by using five kinds of the above-mentioned algorithms, and comparison and analysis is conducted to the fitting results of five kinds of algorithms from four respects: the vulnerability to noises, the accuracy and precision of the fitting, the speed of the fitting and preferable fitting ring-down signal waveform length The research results show that Levenberg-Marquardt algorithm and linear regression of the sum algorithm are able to provide more precise results and prove to have higher noises immunity, and by comparison, the fitting speed of Leven- berg-Marquardt algorithm turns out to be slower. In addition, by analysis of simulated ring-down signals, five to ten times of ring-down time is selected to be the best fitting waveform length because in this case, standard deviation of fitting results of five kinds of algorithms proves to be the minimum. External modulation diode laser and cavity which consists of two high reflectivity mirrors are used to construct a cavity ring-down spectroscopy detection system. According to our experimental conditions, in which the noise level is 0.2%, linear regression of the sum algorithm and Levenberg-Marquardt algorithm are selected to process experimental data. The experimental results show that the accuracy and precision of linear regression of the sum algorithm is considerably close to those of Levenberg-Marquardt algorithm, and on the other hand, the fitting speed of linear regression of the sum algorithm is faster than that of Levenberg-Marquardt algorithm about five times. The experimental results are consistent with the simulation analysis, and it indicates that linear regression of the sum algorithm is the desirable fitting method, as far as our experimental conditions are concerned.
- 1 November 2012
- Vol. 33 (11) , 3718-24
[BTX monitoring nearby main road traffic in Guangzhou].
In order to study the levels of BTX (benzene, toluene, xylene, etc) nearby the main roads of Guangzhou from November 2010 to December 2010 during the Asian Games, BTX and conventional pollutants such as NO2, O3 in the air were monitored by the DOAS system nearby Huangsha Road, which is in the Liwan District of Guangzhou City. The results showed that, during the entire period, BTX showed a high concentration in the evening and the average concentrations of benzene, toluene, p-xylene, m-xylene and phenol were 15.9 microg x m(-3), 61.3 microg x m(-3), 6.5 microg x m(-3), 16.9 microg x m(-3), 0.88 microg x m(-3), respectively. The average concentrations of benzene and toluene were close to those in other cities, and the ratio of toluene to benzene was in range of 1.2-6.16. Throughout the monitoring period, the correlation coefficient of benzene and toluene was 0.86 and it rose to 0.985 during the high concentration period, indicating that they had the same source in this region. The correlation coefficient between toluene and CO was 0.78, indicating that traffic emissions was the major source of benzene and toluene. Based on the combination of wind speed, wind direction and other meteorological data, it was found that the weather condition was an important factor which affected the BTX concentration, and some possible point sources were suggested nearby the site.
- 1 November 2012
- Vol. 33 (11) , 3718-24
[BTX monitoring nearby main road traffic in Guangzhou].
In order to study the levels of BTX (benzene, toluene, xylene, etc) nearby the main roads of Guangzhou from November 2010 to December 2010 during the Asian Games, BTX and conventional pollutants such as NO2, O3 in the air were monitored by the DOAS system nearby Huangsha Road, which is in the Liwan District of Guangzhou City. The results showed that, during the entire period, BTX showed a high concentration in the evening and the average concentrations of benzene, toluene, p-xylene, m-xylene and phenol were 15.9 microg x m(-3), 61.3 microg x m(-3), 6.5 microg x m(-3), 16.9 microg x m(-3), 0.88 microg x m(-3), respectively. The average concentrations of benzene and toluene were close to those in other cities, and the ratio of toluene to benzene was in range of 1.2-6.16. Throughout the monitoring period, the correlation coefficient of benzene and toluene was 0.86 and it rose to 0.985 during the high concentration period, indicating that they had the same source in this region. The correlation coefficient between toluene and CO was 0.78, indicating that traffic emissions was the major source of benzene and toluene. Based on the combination of wind speed, wind direction and other meteorological data, it was found that the weather condition was an important factor which affected the BTX concentration, and some possible point sources were suggested nearby the site.
- 1 November 2012
- Vol. 32 (11) , 2886-90
[Research on the influence of LED temperature shifts on differential optical absorption spectroscopy for measuring NO2].
Influences of LEDs (without etalon structure and center wavelengths are respectively 370 nm (near-UV), 452 nm (blue) and 660 nm(red)) temperature shifts on differential optical absorption spectroscopy(DOAS) for measuring NO2 were studied. NO2 absorption spectra were formed using LED emitting spectra at 10 degrees C. The measured LED spectra at other temperatures were used as reference spectra of DOAS. Thus, NO2 differential optical densities under different LED temperature shifts were acquired and then NO2 differential cross-sections were fitted to the acquired differential optical densities. From fitting results, the linear relations of 0.995, 0.945 and 0.989 correlation between delta of fitting residual and near-UV, blue and red LEDs temperature shifts were found and their slopes are respectively 1.12 x 10(-3), 5.25 x 10(-5) and 7.45 x 10(-4) degrees C(-1). The fitting results show that the influence of temperature shifts of blue LED on DOAS retrieval is negligible and the temperature shifts of near-UV and red LED are impressible to DOAS measurement resulting in degradation of detection sensitivity. The retrieval results of blue LED with and without etalon with similar temperature properties were compared and showed that etalon of LED will greatly increase the influence of temperature shifts of LED on DOAS retrieval.
- 1 November 2012
- Vol. 32 (11) , 2886-90
[Research on the influence of LED temperature shifts on differential optical absorption spectroscopy for measuring NO2].
Influences of LEDs (without etalon structure and center wavelengths are respectively 370 nm (near-UV), 452 nm (blue) and 660 nm(red)) temperature shifts on differential optical absorption spectroscopy(DOAS) for measuring NO2 were studied. NO2 absorption spectra were formed using LED emitting spectra at 10 degrees C. The measured LED spectra at other temperatures were used as reference spectra of DOAS. Thus, NO2 differential optical densities under different LED temperature shifts were acquired and then NO2 differential cross-sections were fitted to the acquired differential optical densities. From fitting results, the linear relations of 0.995, 0.945 and 0.989 correlation between delta of fitting residual and near-UV, blue and red LEDs temperature shifts were found and their slopes are respectively 1.12 x 10(-3), 5.25 x 10(-5) and 7.45 x 10(-4) degrees C(-1). The fitting results show that the influence of temperature shifts of blue LED on DOAS retrieval is negligible and the temperature shifts of near-UV and red LED are impressible to DOAS measurement resulting in degradation of detection sensitivity. The retrieval results of blue LED with and without etalon with similar temperature properties were compared and showed that etalon of LED will greatly increase the influence of temperature shifts of LED on DOAS retrieval.
- 1 July 2012
- Vol. 32 (7) , 1734-8
[Studies on the data processing method in chlorine measurement by differential optical absorption spectroscopy technology].
In this paper, based on Differential Optical Absorption Spectroscopy (DOAS) technique, experimental measurements of chlorine was carried out in the laboratory with a small self-built experimental system. In dealing with the standard cross-section of chlorine, we presented two different methods: triangle filtering and polynomial fitting. Experiments showed that the concentration of chlorine could be accurately retrieved by the latter one. Simulation results showed that the error of retrieval result by fifth-order polynomial fitting was smaller than by other orders and an actual retrieval example shows that the fitting spectrums were nearly coincident with the measured spectrums with a residual delta(peak to peak) below 5 per hundred; The results measured in different sample pools displayed a high linearity of 0.9961 by this method. The main sources of errors during the entire experiment were simply analyzed. According to the experimental result above, it is feasible to detect chlorine using DOAS technology by polynomial fitting.
- 1 July 2012
- Vol. 32 (7) , 1734-8
[Studies on the data processing method in chlorine measurement by differential optical absorption spectroscopy technology].
In this paper, based on Differential Optical Absorption Spectroscopy (DOAS) technique, experimental measurements of chlorine was carried out in the laboratory with a small self-built experimental system. In dealing with the standard cross-section of chlorine, we presented two different methods: triangle filtering and polynomial fitting. Experiments showed that the concentration of chlorine could be accurately retrieved by the latter one. Simulation results showed that the error of retrieval result by fifth-order polynomial fitting was smaller than by other orders and an actual retrieval example shows that the fitting spectrums were nearly coincident with the measured spectrums with a residual delta(peak to peak) below 5 per hundred; The results measured in different sample pools displayed a high linearity of 0.9961 by this method. The main sources of errors during the entire experiment were simply analyzed. According to the experimental result above, it is feasible to detect chlorine using DOAS technology by polynomial fitting.
- 1 February 2012
- Vol. 32 (2) , 476-80
[Study on the measurement of ambient ammonia in urban area based on open-path DOAS technique].
As a key role in the acid-deposition and the generation of secondary particle matter (PM), measurement of the concentration of atmospheric ammonia in urban area has been attracting the scientists' interests nowadays. After studying the special absorption features of ammonia in short UV wavelength range, detailed concernful issues were put forward in the present paper. The decision of using xenon lamp as the light source was made after the evaluation of measurement of light spectroscopy. Retrieval wavelength band for NH3 was fixed from 204 to 214 nm and optimal method of deducting other interferential gases was also shown. A home-made open-path DOAS (OP-DOAS) system was set up for the measurement of the concentration of atmospheric NH3. The detection limit of such system was calculated with the typical noise level as low as 0.33 microg x m(-3) with the optical path 228 m. Through field experiment in Guangzhou city, such a system can be competent for the online and high time-resolution monitoring of the concentration of atmospheric ammonia. With a significant diurnal variation, the atmospheric ammonia changed from 0.83 to 3.11 microg x m(-3) with the mean value 1.59 microg x m(-3). The representative character of the diurnal variation is that the concentration of NH3 peaks during night while drops to bottom in the daytime. After the error analysis procedure, typical measurement accuracy of such OP-DOAS system was within 10%.
- 1 February 2012
- Vol. 32 (2) , 476-80
[Study on the measurement of ambient ammonia in urban area based on open-path DOAS technique].
As a key role in the acid-deposition and the generation of secondary particle matter (PM), measurement of the concentration of atmospheric ammonia in urban area has been attracting the scientists' interests nowadays. After studying the special absorption features of ammonia in short UV wavelength range, detailed concernful issues were put forward in the present paper. The decision of using xenon lamp as the light source was made after the evaluation of measurement of light spectroscopy. Retrieval wavelength band for NH3 was fixed from 204 to 214 nm and optimal method of deducting other interferential gases was also shown. A home-made open-path DOAS (OP-DOAS) system was set up for the measurement of the concentration of atmospheric NH3. The detection limit of such system was calculated with the typical noise level as low as 0.33 microg x m(-3) with the optical path 228 m. Through field experiment in Guangzhou city, such a system can be competent for the online and high time-resolution monitoring of the concentration of atmospheric ammonia. With a significant diurnal variation, the atmospheric ammonia changed from 0.83 to 3.11 microg x m(-3) with the mean value 1.59 microg x m(-3). The representative character of the diurnal variation is that the concentration of NH3 peaks during night while drops to bottom in the daytime. After the error analysis procedure, typical measurement accuracy of such OP-DOAS system was within 10%.