Aleksander Kusiak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Aleksander Kusiak has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Danuta Czarnecka
I Department of Cardiology, Interventional Electrocardiology and Hypertension, Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland
7 shared publications - Jerzy Wiliński
Department of Internal Medicine with Cardiology Subdivision, Blessed Marta Wiecka District Hospital, Bochnia, Poland; Center for Invasive Cardiology, Electrotherapy and Angiology, Intercard LLC, Nowy Sącz, Poland
6 shared publications Tomasz Sondej
First Department of Cardiology, Interventional Electrocardiology and Hypertension Jagiellonian University, Medical College Krakow Poland
6 shared publications- Marek Jastrzębski
First Department of Cardiology, Interventional Electrocardiology and Hypertension, Jagiellonian University, Medical College , Krakow
5 shared publications - Małgorzata Kloch-Badełek
Department of Medical Education, Center for Innovative Medical Education, Jagiellonian University Medical College, Kraków, Poland
3 shared publications Wiktoria Wojciechowska
Department of Cardiology, Interventional Electrocardiology and Anterial Hypertension, the University Hospital, Krakow, Poland
3 shared publications
Latest Publications
- 8 May 2023
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 46 (7) , 629-638
Left bundle branch area pacing prevents pacing induced cardiomyopathy in long‐term observation
Background: Left bundle branch area pacing (LBBAP) is one of the methods to deliver conduction system pacing which potentially avoids the negative impact of conventional right ventricular pacing.Objective: To assess echocardiographic outcomes in a long‐term observation in patients with LBBAP implemented for bradyarrhythmia indications.Methods and Results: A total of 151 patients with symptomatic bradycardia and LBBAP pacemaker implanted, were prospectively included in the study. Subjects with left bundle branch block and CRT indications (n = 29), ventricular pacing burden n = 11), and loss of LBBAP (n = 10) were excluded from further analysis. At baseline and the last follow‐up visit, echocardiography with global longitudinal strain (GLS) assessment, 12‐lead ECG, pacemaker interrogation, and blood level of NT‐proBNP were performed. The median follow‐up period was 23 months (15.5–28). None of the analyzed patients fulfilled the criteria for pacing induced cardiomyopathy (PICM). Improvement in left ventricular ejection fraction (LVEF) and GLS was observed in patients with LVEF n = 39): 41.4 ± 9.2% versus 45.6 ± 9.9%, and 12.9 ± 3.6% versus 15.5 ± 3.7%, respectively. In the subgroup with preserved EF (n = 62), LVEF and GLS remained stable at follow‐up: 59.3 ± 5.5% versus 60 ± 5.5%, and 19 ± 3.9% versus 19.4 ± 3.8%, respectively.Conclusion: LBBAP prevents PICM in patients with preserved LVEF and improves left ventricle function in subjects with depressed LVEF. LBBAP might be the preferred pacing modality for bradyarrhythmia indications.
- 8 May 2023
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 46 (7) , 629-638
Left bundle branch area pacing prevents pacing induced cardiomyopathy in long‐term observation
Background: Left bundle branch area pacing (LBBAP) is one of the methods to deliver conduction system pacing which potentially avoids the negative impact of conventional right ventricular pacing.Objective: To assess echocardiographic outcomes in a long‐term observation in patients with LBBAP implemented for bradyarrhythmia indications.Methods and Results: A total of 151 patients with symptomatic bradycardia and LBBAP pacemaker implanted, were prospectively included in the study. Subjects with left bundle branch block and CRT indications (n = 29), ventricular pacing burden n = 11), and loss of LBBAP (n = 10) were excluded from further analysis. At baseline and the last follow‐up visit, echocardiography with global longitudinal strain (GLS) assessment, 12‐lead ECG, pacemaker interrogation, and blood level of NT‐proBNP were performed. The median follow‐up period was 23 months (15.5–28). None of the analyzed patients fulfilled the criteria for pacing induced cardiomyopathy (PICM). Improvement in left ventricular ejection fraction (LVEF) and GLS was observed in patients with LVEF n = 39): 41.4 ± 9.2% versus 45.6 ± 9.9%, and 12.9 ± 3.6% versus 15.5 ± 3.7%, respectively. In the subgroup with preserved EF (n = 62), LVEF and GLS remained stable at follow‐up: 59.3 ± 5.5% versus 60 ± 5.5%, and 19 ± 3.9% versus 19.4 ± 3.8%, respectively.Conclusion: LBBAP prevents PICM in patients with preserved LVEF and improves left ventricle function in subjects with depressed LVEF. LBBAP might be the preferred pacing modality for bradyarrhythmia indications.
- Open Access
- 21 December 2019
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 25 (4) , e12733
Diagnostic value of implantable loop recorder in patients undergoing cryoballoon ablation of atrial fibrillation
Background: Due to limited data, implantable loop recorders (ILR) are not currently recommended by the guidelines to routinely monitor patients after atrial fibrillation (AF) ablation.Aims: To validate the diagnostic value of ILR after AF ablation, modern generation ILRs (LINQ) were implanted in patients scheduled for cryoballoon ablation of AF (CBA).Methods: We included 29 patients with frequent and symptomatic episodes of paroxysmal AF. ILR was implanted 3 months prior to CBA, and data were collected before and for 6 months after the procedure. The device was programmed to maximize sensitivity of AF/ atrial tachycardia (AT) detection. All EGM recordings were “manually” assessed and annotated as true AF, pseudo AF, unrecognized AF, and episodes with no EGM available. Duration and episode‐based standard performance metrics were evaluated.Results: A total number of 5,842 episodes were recorded. A total of 4,403 episodes were true AF, 453 episodes were pseudo AF, and 986 episodes had no EGM available. The device did not recognize 144 episodes of AF. Duration‐based sensitivity was 95.2%, duration‐based specificity 99.9%, duration‐based PPV 99.2%, duration‐based NPV 99.9%, episode‐based sensitivity 98.0%, and episode‐based PPV 91.0%. Misdiagnosis happened in 1 in 10 episodes. Total data review time was 166 hr.Conclusions: Implantable loop recorders is a valuable tool in evaluation of AF episodes in patients undergoing CBA. However, for high precision all recorded episodes need to be evaluated “manually.” The memory storage space is too low for frequent AF episodes, resulting in overwriting of stored EGMs and data loss.
- 21 December 2019
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 25 (4) , e12733
Open AccessDiagnostic value of implantable loop recorder in patients undergoing cryoballoon ablation of atrial fibrillation
Background: Due to limited data, implantable loop recorders (ILR) are not currently recommended by the guidelines to routinely monitor patients after atrial fibrillation (AF) ablation.Aims: To validate the diagnostic value of ILR after AF ablation, modern generation ILRs (LINQ) were implanted in patients scheduled for cryoballoon ablation of AF (CBA).Methods: We included 29 patients with frequent and symptomatic episodes of paroxysmal AF. ILR was implanted 3 months prior to CBA, and data were collected before and for 6 months after the procedure. The device was programmed to maximize sensitivity of AF/ atrial tachycardia (AT) detection. All EGM recordings were “manually” assessed and annotated as true AF, pseudo AF, unrecognized AF, and episodes with no EGM available. Duration and episode‐based standard performance metrics were evaluated.Results: A total number of 5,842 episodes were recorded. A total of 4,403 episodes were true AF, 453 episodes were pseudo AF, and 986 episodes had no EGM available. The device did not recognize 144 episodes of AF. Duration‐based sensitivity was 95.2%, duration‐based specificity 99.9%, duration‐based PPV 99.2%, duration‐based NPV 99.9%, episode‐based sensitivity 98.0%, and episode‐based PPV 91.0%. Misdiagnosis happened in 1 in 10 episodes. Total data review time was 166 hr.Conclusions: Implantable loop recorders is a valuable tool in evaluation of AF episodes in patients undergoing CBA. However, for high precision all recorded episodes need to be evaluated “manually.” The memory storage space is too low for frequent AF episodes, resulting in overwriting of stored EGMs and data loss.
- Open Access
- 1 January 2015
- Published by Termedia Sp. z.o.o. in Archives of Medical Science
- Vol. 4 (4) , 736-742
Clinical research Echocardiographic assessment of right ventricular function in responders and non-responders to cardiac resynchronization therapy
Introduction : The aim of this study was to determine whether baseline right ventricular (RV) function assessed by standard echocardiography may indicate patients who will respond to cardiac resynchronization therapy (CRT). Material and methods : The data of 57 patients (54 men, 95%), aged...
- 1 January 2015
- Published by Termedia Sp. z.o.o. in Archives of Medical Science
- Vol. 4 (4) , 736-742
Open AccessClinical research Echocardiographic assessment of right ventricular function in responders and non-responders to cardiac resynchronization therapy
Introduction : The aim of this study was to determine whether baseline right ventricular (RV) function assessed by standard echocardiography may indicate patients who will respond to cardiac resynchronization therapy (CRT). Material and methods : The data of 57 patients (54 men, 95%), aged...
- 1 January 2014
- Vol. 71 (2) , 61-5
Heart rate variability in the course of ST--segment elevation myocardial infarction treated with primary percutaneous transluminal coronary angioplasty in elderly and younger patients.
The aim of the study was to appraise time domain heart rate variability (HRV) parameters in patients with ST-segment elevation myocardial infarction (STEMI) in different age groups. Retrospective analysis included 357 consecutive patients in sinus rhythm without diabetes, aged 27-87 years (mean age--63.0 +/- 11.8 years, 243 men) treated with primary percutaneous transluminal coronary angioplasty (PTCA) due to first in their life STEMI. Each patient had an echocardiographic examination and 24-hour ECG monitoring results interpreted. Participants were divided in the analysis applying the WHO old age criterion into two groups: group A < 65 years old (n = 188) and B aged > or = 65 years (n = 169). In the whole study group age negatively correlated with SDNN, SDANNI, SDNNI and EF, whereas positive correlation between EF and SDANN, and EF and SDNNI was observed. Elderly patients as compared to the younger individuals had significantly diminished SDNN, SDANN, SDNNI and more often SDNN < 70 ms (33.7% vs 20.7%, p < 0.0001). When the circumflex artery lesion was the cause of myocardial infarction SDNN and SDANN were significantly lower in the group B, whereas in case of PTCA of RCA, apart from decreased SDNN and SDANN, EF was also compromised in this group. Elderly patients with myocardial infarction with ST-segment elevation treated with primary PTCA, compared to the younger age group, are characterized by increased sympathetic activation assessed by heart rate variability and heart rate in 24-hour ECG monitoring.
- 1 January 2014
- Vol. 71 (2) , 61-5
Heart rate variability in the course of ST--segment elevation myocardial infarction treated with primary percutaneous transluminal coronary angioplasty in elderly and younger patients.
The aim of the study was to appraise time domain heart rate variability (HRV) parameters in patients with ST-segment elevation myocardial infarction (STEMI) in different age groups. Retrospective analysis included 357 consecutive patients in sinus rhythm without diabetes, aged 27-87 years (mean age--63.0 +/- 11.8 years, 243 men) treated with primary percutaneous transluminal coronary angioplasty (PTCA) due to first in their life STEMI. Each patient had an echocardiographic examination and 24-hour ECG monitoring results interpreted. Participants were divided in the analysis applying the WHO old age criterion into two groups: group A < 65 years old (n = 188) and B aged > or = 65 years (n = 169). In the whole study group age negatively correlated with SDNN, SDANNI, SDNNI and EF, whereas positive correlation between EF and SDANN, and EF and SDNNI was observed. Elderly patients as compared to the younger individuals had significantly diminished SDNN, SDANN, SDNNI and more often SDNN < 70 ms (33.7% vs 20.7%, p < 0.0001). When the circumflex artery lesion was the cause of myocardial infarction SDNN and SDANN were significantly lower in the group B, whereas in case of PTCA of RCA, apart from decreased SDNN and SDANN, EF was also compromised in this group. Elderly patients with myocardial infarction with ST-segment elevation treated with primary PTCA, compared to the younger age group, are characterized by increased sympathetic activation assessed by heart rate variability and heart rate in 24-hour ECG monitoring.
- 7 November 2013
- Published by Index Copernicus in In a Good Rhythm
- Vol. 4 (29) , 20-25
Zastosowanie ablacji tętnic nerkowych w terapii niewydolności serca – i nie tylko
- 7 November 2013
- Published by Index Copernicus in In a Good Rhythm
- Vol. 4 (29) , 20-25
Zastosowanie ablacji tętnic nerkowych w terapii niewydolności serca – i nie tylko
- 1 January 2013
- Vol. 70 (11) , 900-3
[Selection and maintenance of the blood pressure monitor for self-blood pressure monitoring (SBPM)].
The choice of an attested blood pressure (BP) monitor with an adequate arm cuff size and its proper maintenance are crucial for obtaining reliable results in Self-Blood Pressure Monitoring (SBPM) practice. The aim of the study was to assess the factors determining the BP monitor selection, its purchase place and technical use aspects. Two hun. dred consecutive patients with arte. rial hypertension regularly performing SBPM (100 individuals from a munici. pal primary health care centre and 100 from a specialized hypertension office at a university cardiology clinic, aged 57.7 +/-12.4 years, 54.0% female) have undergone an inquiry study based on the European Society of Hyperten. sion (ESH) guidelines for home BP monitoring. Almost half of the re. spondents are utilizing BP monitors that are not routinely recommended for SBPM: wrist devices - 22.0%, aneroid appliances -15.0%, mercury monitors - 7.0% and finger monitors - 1.0%. Only 45.0% of the study participants have checked if the cuff size is ap. propriate, whereas arm circumference in 26.0% of the patients exceeded 34 cm and in 3.5% of the individuals was below 24 cm. As few as 2.5% of SBPM practitioners perform regular techni. cal checkups of their BP monitors. Patients of a specialized hypertension office have significantly more often chosen their BP apparatus according to the doctor's recommendation than primary health care patients (27.0% vs 12.0%, p=0.007, respectively). Sphygmomanometer type and appropriate arm cuff size selections for SBPM is random. The aspects of BP monitor attest and its proper maintenance are neglected. Physicians recommend an adequate BP apparatus choice too rarely.
- 1 January 2013
- Vol. 70 (11) , 900-3
[Selection and maintenance of the blood pressure monitor for self-blood pressure monitoring (SBPM)].
The choice of an attested blood pressure (BP) monitor with an adequate arm cuff size and its proper maintenance are crucial for obtaining reliable results in Self-Blood Pressure Monitoring (SBPM) practice. The aim of the study was to assess the factors determining the BP monitor selection, its purchase place and technical use aspects. Two hun. dred consecutive patients with arte. rial hypertension regularly performing SBPM (100 individuals from a munici. pal primary health care centre and 100 from a specialized hypertension office at a university cardiology clinic, aged 57.7 +/-12.4 years, 54.0% female) have undergone an inquiry study based on the European Society of Hyperten. sion (ESH) guidelines for home BP monitoring. Almost half of the re. spondents are utilizing BP monitors that are not routinely recommended for SBPM: wrist devices - 22.0%, aneroid appliances -15.0%, mercury monitors - 7.0% and finger monitors - 1.0%. Only 45.0% of the study participants have checked if the cuff size is ap. propriate, whereas arm circumference in 26.0% of the patients exceeded 34 cm and in 3.5% of the individuals was below 24 cm. As few as 2.5% of SBPM practitioners perform regular techni. cal checkups of their BP monitors. Patients of a specialized hypertension office have significantly more often chosen their BP apparatus according to the doctor's recommendation than primary health care patients (27.0% vs 12.0%, p=0.007, respectively). Sphygmomanometer type and appropriate arm cuff size selections for SBPM is random. The aspects of BP monitor attest and its proper maintenance are neglected. Physicians recommend an adequate BP apparatus choice too rarely.
- 1 January 2012
- Vol. 70 (9) , 883-8
Effects of biventricular pacing on right ventricular function assessed by standard echocardiography.
The aim of this study was to evaluate the short term effect of cardiac resynchronisation therapy (CRT) on right ventricular (RV) function assessed by standard echocardiography. Data from 57 patients (54 men, 95%; three women, 5%), aged 66.4 ± 8.7 years with heart failure (HF) was analysed. All patients were in NYHA III-IV functional classes, despite optimal pharmacological treatment according to the current guidelines, had left ventricular ejection fraction ≤ 35% and QRS complex ≥ 120 ms in a standard electrocardiogram. At baseline and three months after CRT implantation the patients' histories were taken, an anthropometrical examination was made, laboratory tests including the level of NT-proBNP and electrocardiogram were performed, and echocardiographic examination was extended by tissue Doppler imaging techniques and complex RV evaluation. Three months after CRT implantation in the whole study group, the average NYHA functional class had decreased from 3.11 ± 0.28 to 2.25 ± 0.68 (p < 0.001), and the six-minute walk test distance had increased from 298.04 ± 107.42 m to 373.12 ± 127.15 m (p < 0.001). CRT improved RV systolic function in the whole study group. Tricuspid annular plane systolic excursion had increased from 13.95 ± 2.80 to 15.79 ± 2.33 mm (p < 0.001), and so likewise had systolic excursion velocity (S'), which rose from 8.84 ± 3.45 to 11.00 ± 3.43 cm/s (p < 0.001). Tricuspid regurgitation grade decreased from 2.02 ± 0.95 to 1.86 ± 0.91 (p = 0.013). RV systolic pressure decreased from 31.07 ± 20.43 to 27.75 ± 17.35 mm Hg (p < 0.001). RV fractional area change rose from 31.35 ± 10.30% to 35.40 ± 10.51% (p < 0.001). This study showed that CRT improved RV systolic function evaluated with parameters assessed in standard echocardiographic examination three months after therapy initiation. The observed improvement was consistent among all applied echocardiographic parameters reflecting RV systolic function.
- 1 January 2012
- Vol. 70 (9) , 883-8
Effects of biventricular pacing on right ventricular function assessed by standard echocardiography.
The aim of this study was to evaluate the short term effect of cardiac resynchronisation therapy (CRT) on right ventricular (RV) function assessed by standard echocardiography. Data from 57 patients (54 men, 95%; three women, 5%), aged 66.4 ± 8.7 years with heart failure (HF) was analysed. All patients were in NYHA III-IV functional classes, despite optimal pharmacological treatment according to the current guidelines, had left ventricular ejection fraction ≤ 35% and QRS complex ≥ 120 ms in a standard electrocardiogram. At baseline and three months after CRT implantation the patients' histories were taken, an anthropometrical examination was made, laboratory tests including the level of NT-proBNP and electrocardiogram were performed, and echocardiographic examination was extended by tissue Doppler imaging techniques and complex RV evaluation. Three months after CRT implantation in the whole study group, the average NYHA functional class had decreased from 3.11 ± 0.28 to 2.25 ± 0.68 (p < 0.001), and the six-minute walk test distance had increased from 298.04 ± 107.42 m to 373.12 ± 127.15 m (p < 0.001). CRT improved RV systolic function in the whole study group. Tricuspid annular plane systolic excursion had increased from 13.95 ± 2.80 to 15.79 ± 2.33 mm (p < 0.001), and so likewise had systolic excursion velocity (S'), which rose from 8.84 ± 3.45 to 11.00 ± 3.43 cm/s (p < 0.001). Tricuspid regurgitation grade decreased from 2.02 ± 0.95 to 1.86 ± 0.91 (p = 0.013). RV systolic pressure decreased from 31.07 ± 20.43 to 27.75 ± 17.35 mm Hg (p < 0.001). RV fractional area change rose from 31.35 ± 10.30% to 35.40 ± 10.51% (p < 0.001). This study showed that CRT improved RV systolic function evaluated with parameters assessed in standard echocardiographic examination three months after therapy initiation. The observed improvement was consistent among all applied echocardiographic parameters reflecting RV systolic function.
- 1 January 2011
- Vol. 68 (7) , 359-61
The influence of cardiac resynchronization therapy on selected inflammatory markers and aldosterone levels in patients with chronic heart failure.
The aim of the study was to assess the influence of cardiac resynchronization therapy(CRT) on a series of humoral parameters crucial for the pathophysiology of chronic heart failure such as aldosterone or the inflammatory markers. Thirty eight consecutive patients (aged 66.3 +/- 9.6 years, 31 men - 82% ) with chronic heart failure (57.9% with ischaemic background and 42.1% of non-ischaemic etiology) in stable for at least 3 months, NYHA class III - IV despite optimized pharmacotherapy, with left ventricular ejection fraction (LVEF) < or = 35% and wide QRS complex (> or = 120 ms) had the blood serum tested for the concentrations of interleukin-6 (IL-6), interleukin-18 (IL-18), C-reactive protein (CRP) and aldosterone before and 12-16 weeks after CRT introduction. In the study group aldosterone concentrations were significantly reduced. Among the inflammatory markers the level of IL-6 decreased, IL-18 concentrations showed a falling trend (445.1 +/- 225.7 pg/ml vs 418.4 +/- 229.6 pg/ml, p = 0.052), whereas no change of CRP serum contain was noted. It was showed that cardiac resynchronization therapy had an impact on systemic inflammation and hormonal status in patients with chronic heart failure during short-term observation.
- 1 January 2011
- Vol. 68 (7) , 359-61
The influence of cardiac resynchronization therapy on selected inflammatory markers and aldosterone levels in patients with chronic heart failure.
The aim of the study was to assess the influence of cardiac resynchronization therapy(CRT) on a series of humoral parameters crucial for the pathophysiology of chronic heart failure such as aldosterone or the inflammatory markers. Thirty eight consecutive patients (aged 66.3 +/- 9.6 years, 31 men - 82% ) with chronic heart failure (57.9% with ischaemic background and 42.1% of non-ischaemic etiology) in stable for at least 3 months, NYHA class III - IV despite optimized pharmacotherapy, with left ventricular ejection fraction (LVEF) < or = 35% and wide QRS complex (> or = 120 ms) had the blood serum tested for the concentrations of interleukin-6 (IL-6), interleukin-18 (IL-18), C-reactive protein (CRP) and aldosterone before and 12-16 weeks after CRT introduction. In the study group aldosterone concentrations were significantly reduced. Among the inflammatory markers the level of IL-6 decreased, IL-18 concentrations showed a falling trend (445.1 +/- 225.7 pg/ml vs 418.4 +/- 229.6 pg/ml, p = 0.052), whereas no change of CRP serum contain was noted. It was showed that cardiac resynchronization therapy had an impact on systemic inflammation and hormonal status in patients with chronic heart failure during short-term observation.
- 1 January 2010
- Vol. 67 (12) , 1249-52
Effects of cardiac resynchronization therapy on sleep apnea, quality of sleep and daytime sleepiness in patients with chronic heart failure.
Sleep-related breathing disorders are common in patients with chronic heart failure (CHF) and contribute to exacerbation of CHF. The effects of biventricular stimulation (CRT) seem to exceed the improvement of mechanical heart performance and are likely to affect other aspects of CHF pathophysiology. The aim of the study was to assess the influence of CRT on subjective and objective sleep features. Twenty seven consecutive patients (aged 67.7 +/- 8.7 years, 23 men - 85%) with chronic heart failure (62.9% with ischaemic background and 37.1% of non-ischaemic etiology) in stable for at least 3 months NYHA class III - IV despite optimized pharmacotherapy, with left ventricular end-diastolic diameter (LVEDd) > 55 mm, left ventricular ejection fraction (LVEF) < or = 35% and wide QRS complex (> or = 120 ms) were appraised before and 12-16 weeks after CRT introduction clinically (including 6-minute walk test--6-MWT), echocardiographically and in polisomnography. The apnea-hypopnea index (AHI) and apnea indexes (AI) of central, obstructive and mixed types were calculated. The sleep quality was assessed with the Pittsburgh Sleep Quality Index (PSQI), daytime sleepiness with the Epworth Sleepiness Scale (ESS). LVEF increased, 6-MWT distance rose. Left ventricular diameters and left ventricular end-systolic volume decreased. PQSI and ESS fell (9.3 +/- 4.2 vs 6.2 +/- 3.2, p < 0.001 and 8.4 +/- 4.1 vs 7.0 +/- 3.4, p < 0.001, respectively). AHI, obstructive AL and mixed AL did not alter but significant reduction of central AL was noted (9.6 +/- 13.0 vs 3.7 +/- 6.2, p = 0.023). CRT decreases central sleep apnea and improves quality of sleep and daytime sleepiness in patients with CHF.
- 1 January 2010
- Vol. 67 (12) , 1249-52
Effects of cardiac resynchronization therapy on sleep apnea, quality of sleep and daytime sleepiness in patients with chronic heart failure.
Sleep-related breathing disorders are common in patients with chronic heart failure (CHF) and contribute to exacerbation of CHF. The effects of biventricular stimulation (CRT) seem to exceed the improvement of mechanical heart performance and are likely to affect other aspects of CHF pathophysiology. The aim of the study was to assess the influence of CRT on subjective and objective sleep features. Twenty seven consecutive patients (aged 67.7 +/- 8.7 years, 23 men - 85%) with chronic heart failure (62.9% with ischaemic background and 37.1% of non-ischaemic etiology) in stable for at least 3 months NYHA class III - IV despite optimized pharmacotherapy, with left ventricular end-diastolic diameter (LVEDd) > 55 mm, left ventricular ejection fraction (LVEF) < or = 35% and wide QRS complex (> or = 120 ms) were appraised before and 12-16 weeks after CRT introduction clinically (including 6-minute walk test--6-MWT), echocardiographically and in polisomnography. The apnea-hypopnea index (AHI) and apnea indexes (AI) of central, obstructive and mixed types were calculated. The sleep quality was assessed with the Pittsburgh Sleep Quality Index (PSQI), daytime sleepiness with the Epworth Sleepiness Scale (ESS). LVEF increased, 6-MWT distance rose. Left ventricular diameters and left ventricular end-systolic volume decreased. PQSI and ESS fell (9.3 +/- 4.2 vs 6.2 +/- 3.2, p < 0.001 and 8.4 +/- 4.1 vs 7.0 +/- 3.4, p < 0.001, respectively). AHI, obstructive AL and mixed AL did not alter but significant reduction of central AL was noted (9.6 +/- 13.0 vs 3.7 +/- 6.2, p = 0.023). CRT decreases central sleep apnea and improves quality of sleep and daytime sleepiness in patients with CHF.