  • Strength evaluation of prosthetic check sockets, copolymer sockets, and definitive laminated sockets

    by Maria J. Gerschutz, Michael L. Haynes, Derek Nixon, James M. Colvin

    A prosthesis encounters loading through forces and torques exerted by the person with amputation. International Organization for Standardization (ISO) standard 10328 was designed to test most lower-limb prosthetic components. However, this standard does not include prosthetic sockets. We measured static failure loads of prosthetic sockets using a modified ISO 10328 and then compared them with the criteria set by this standard for other components. Check socket (CS) strengths were influenced by thickness, material choice, and fabrication method. Copolymer socket (CP) strengths depended on thickness and fabrication methods. A majority of the CSs and all of the CPs failed to pass the ISO 10328 ductile loading criterion. In contrast, the strengths of definitive laminated sockets (DLs) were influenced more by construction material and technique. A majority of the DLs failed to pass the ISO 10328 brittle loading criterion. Analyzing prosthetic sockets from a variety of facilities demonstrated that socket performance varies considerably between and within facilities. The results from this article provide a foundation for understanding the quality of prosthetic sockets, some insight into possible routes for improving the current care delivered to patients, and a comparative basis for future technology.


  • Tensile strength and impact resistance properties of materials used in prosthetic check sockets, copolymer sockets, and definitive laminated sockets

    by Maria J. Gerschutz, Michael L. Haynes, Derek M. Nixon, James M. Colvin

    Prosthetic sockets serve as the interface between people with amputations and their prostheses. Although most materials used to make prosthetic sockets have been used for many years, knowledge of these materials' properties is limited, especially after they are subjected to fabrication processes. This study evaluated tensile and impact properties of the current state-of-the-art materials used to fabricate prosthetic check sockets, copolymer sockets, and definitive laminated sockets. Thermolyn Rigid and Orfitrans Stiff check socket materials produced significantly lower tensile strength and impact resistance than polyethylene terephthalate glycol (PETG). Copolymer socket materials exhibited greater resistance to impact forces than the check socket materials but lower tensile strengths than PETG. The heated molding processes, for the check socket and copolymer materials, reduced both tensile strength and elongation at break. Definitive laminated sockets were sorted according to fabrication techniques. Nyglass material had significantly higher elongation, indicating a more ductile material than carbon-based laminations. Carbon sockets with pigmented resin had higher tensile strength and modulus at break than nonpigmented carbon sockets. Elongation at yield and elongation at break were similar for both types of carbon-based laminations. The material properties determined in this study provide a foundation for understanding and improving the quality of prosthetic sockets using current fabrication materials and a basis for evaluating future technologies.


  • A Vacuum Suspension Measurement Tool for Use in Prosthetic Research and Clinical Outcomes: Validation and Analysis of Vacuum Pressure in a Prosthetic Socket

    by Maria J. Gerschutz, Michael L. Haynes, James M. Colvin, Derek Bs Nixon, Jeffery A. Cp Denune, Glenn Cp Schober

    The use of vacuum suspension (VS) in the prosthetic field has increased dramatically. However, knowledge regarding the mechanics of VS, the loading responses on the soft tissue, the short-term effects on perfusion, and the long-term effects on the residual limb are limited. In addition, little is known about what level of vacuum should be considered sufficient. Currently, there are no tools available to monitor the vacuum in a socket, how it varies with time, or the actual patient usage. This article presents a tool, the LimbLogic VS Communicator (The Ohio Willow Wood Company, Mt. Sterling, OH), that allows these types of studies to be performed in a nonintrusive manner, with the intent of facilitating the understanding and appropriate usage of VS systems. In this article, the accuracy of the LimbLogic VS Communicator is verified to the same standards as the LimbLogic VS System (accuracy: ±1 in Hg [±3.39 kPa]). The average accuracy of the LimbLogic VS Communicator, which is dependent on the VS pressure setting, is determined to be ±0.5 in Hg (±1.69 kPa). In addition, a study on the distribution of vacuum levels in a socket is presented. This VS measurement tool may simplify many possible future experiments in the prosthetic field.