MDMarcelo Antonialli Del'acqua

Marcelo Antonialli Del'acqua

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marcelo Antonialli Del'acqua has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 23 May 2012
      • Vol. 27  (3) , 544-50

    Comparison of the accuracy of plastic and metal stock trays for implant impressions.

    by Marcelo Antonialli Del'acqua, Érica Dorigatti De Avila, Ângela Líbia Chagas Amaral, Ligia Pinelli, Francisco De Assis Mollo

    This in vitro study evaluated the dimensional accuracy of two impression techniques (tapered and splinted) with two stock trays (plastic and metal) for implant-supported prostheses. A master cast with four parallel abutment analogs and a passive framework were fabricated. Polyvinyl siloxane impression material was used for all impressions with two metal stock trays and two plastic stock trays (closed and open trays). Four groups (tapered plastic, splinted plastic, tapered metal, and splinted metal) and a control group (master cast) were tested (n = 5 for each group). After the framework was seated on each of the casts, one abutment screw was tightened, and the marginal gap between the abutment and framework on the other side was measured with a stereomicroscope. The measurements were analyzed with the Kruskal-Wallis one-way analysis of variance on ranks test followed by the Dunn method. The mean values (± standard deviations) for the abutment/framework interface gaps were: master cast, 32 ± 2 Μm; tapered metal, 44 ± 10 Μm; splinted metal, 69 ± 28 Μm; tapered plastic, 164 ± 58 Μm; splinted plastic, 128 ± 47 Μm. No significant difference was detected between the master cast, tapered metal, and splinted metal groups or between the tapered and splinted plastic groups. In this study, the rigidity of the metal stock tray ensured better results than the plastic stock tray for implant impressions with a high-viscosity impression material (putty). Statistically similar results were obtained using tapered impression copings and splinted squared impression copings. The tapered impression copings technique and splinted squared impression copings technique with a metal stock tray produced precise casts with no statistically significant difference in interface gaps compared to the master cast.


    • 5 January 2011
      • Vol. 25  (6) , 1153-8

    The effect of splint material rigidity in implant impression techniques.

    by Marcelo Antonialli Del Acqua, Alejandro Munoz Chavez, Sabrina Maria Castanharo, Marco Antonio Compagnoni, Francisco De Assis Mollo

    This in vitro study compared the dimensional accuracy of two impression techniques: Duralay splinted impression copings (D) and metal splinted impression copings (M) for implant-supported prostheses. A master cast with four parallel implant abutment analogs and a passive framework were fabricated. Vinyl polysiloxane impression material was used for all impressions with a metal stock tray. Two groups (D and M) were tested (n = 5). The measurement method employed was just one titanium screw tightened to the framework. Each group's measurements were analyzed using software that received the images of a video camera coupled to a stereomicroscope at 3100 magnification. The results were analyzed statistically (t test). The mean values of abutment/framework interface gaps were: master cast = 32 Μm (SD 2), group D =165 Μm (SD 60), and group M = 69 Μm (SD 36). There was a statistically significant difference between the D and M groups (P ⋜ .001). Under the limitations of this study, it could be suggested that a more accurate working cast can be fabricated using metal splinted impression copings.


    • 27 July 2010
      • Vol. 25  (4) , 715-21

    Accuracy of impression techniques for an implant-supported prosthesis.

    by Marcelo Antonialli Del'acqua, Alejandro Muñoz Chávez, Marco Antonio Compagnoni, Francisco De Assis Molo

    This in vitro study compared the dimensional accuracy of a stone index and of two impression techniques (squared impression copings and modified squared impression copings) for implant-supported prostheses. A master cast with four parallel implant-abutment analogs and a passive framework were fabricated. Vinyl polysiloxane impression material was used for all impressions with a metal stock tray. Three groups of impressions were tested (n = 5): index (I), squared (S), and modified squared (MS). The measurement method employed was just one titanium screw tightened to the framework. The measurements (60 gap values) were analyzed using software that received the images from a video camera coupled to a stereomicroscope at 3100 magnification. The results were evaluated statistically (analysis of variance, Holm-Sidak method, α = .05). The mean abutment/framework interface gaps were: master cast = 31.63 µm; group I = 45.25 µm; group S = 96.14 µm; group MS = 51.20 µm. No significant difference was detected among the index and modified squared techniques (P = .05). Under the limitations of this study, the techniques modified squared and index generated more accurate casts than the squared technique.


    • 27 July 2010
      • Vol. 25  (4) , 771-6

    Comparison of impression techniques and materials for an implant-supported prosthesis.

    by Marcelo Antonialli Del'acqua, Alejandro Muñoz Chávez, Angela Líbia Chagas Amaral, Marco Antonio Compagnoni, Francisco De Assis Mollo

    To investigate, in vitro, the dimensional accuracy of two impression techniques (squared impression copings and squared impression copings sandblasted and coated with impression adhesive) made of vinyl polysiloxane and polyether impression materials. A master cast (control group) with four parallel implant abutment analogs, a passive framework, and a custom aluminum tray was fabricated. Four groups (n = 5 each group) were tested: squared Impregum (SI), squared Express (SE), sandblasted adhesive squared Impregum (ASI), and sandblasted adhesive squared Express (ASE). The measurement method employed was just one titanium screw tightened to the framework. A stereomicroscope was used to evaluate the fit of the framework by measuring the size of the gap between the abutment and the framework. The results were analyzed statistically. The mean values for the abutment/framework interface gaps were: master cast, 31.63 µm (SD 2.16); SI, 38.03 µm (SD 9.29); ASI, 46.80 µm (SD 8.47); SE, 151.21 µm (SD 22.79); and ASE, 136.59 µm (SD 29.80). No significant difference was detected between the SI or ASI techniques and the master cast. No significant difference was detected between the SE and ASE techniques. Within the limitations of this study, it can be concluded that Impregum Soft medium consistency was the best impression material and the impression technique did not influence the accuracy of the stone casts.


    • 14 June 2008
      • Vol. 23  (2) , 226-36

    Accuracy of impression and pouring techniques for an implant-supported prosthesis.

    by Marcelo Antonialli Del'Acqua, João Neudenir Arioli-Filho, Marco Antonio Compagnoni, Francisco De Assis Mollo

    The purpose of this in vitro study was to compare the dimensional accuracy of a stone index and of 3 impression techniques (tapered impression copings, squared impression copings, and squared impression copings splinted with acrylic resin) associated with 3 pouring techniques (conventional, pouring using latex tubes fitted onto analogs, and pouring after joining the analogs with acrylic resin) for implant-supported prostheses. A mandibular brass cast with 4 stainless steel implant-abutment analogs, a framework, and 2 aluminum custom trays were fabricated. Polyether impression material was used for all impressions. Ten groups were formed (a control group and 9 test groups formed by combining each pouring technique and impression technique). Five casts were made per group for a total of 50 casts and 200 gap values (1 gap value for each implant-abutment analog). The mean gap value with the index technique was 27.07 microm. With the conventional pouring technique, the mean gap values were 116.97 microm for the tapered group, 57.84 microm for the squared group, and 73.17 microm for the squared splinted group. With pouring using latex tubes, the mean gap values were 65.69 microm for the tapered group, 38.03 microm for the squared group, and 82.47 microm for the squared splinted group. With pouring after joining the analogs with acrylic resin, the mean gap values were 141.12 microm for the tapered group, 74.19 microm for the squared group, and 104.67 microm for the squared splinted group. No significant difference was detected among Index, square/latex techniques, and master cast (P >.05). The most accurate impression technique utilized squared copings. The most accurate pouring technique for making the impression with tapered or squared copings utilized latex tubes. The pouring did not influence the accuracy of the stone casts when using splinted squared impression copings. Either the index technique or the use of squared coping combined with the latex-tube pouring technique are preferred methods for making implant-supported fixed restorations with dimensional accuracy.