Jordanna M Forman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jordanna M Forman has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Kenneth Andrew Egol
New York University Langone Orthopedic Hospital, New York, USA
2 shared publications Adriana M Urruela
1 shared publication- Raj Karia
Center for Clinical Research, Department of Orthopaedic Surgery, NYU Hospital for Joint Diseases, 301 East 17th Street, New York, NY 10003, USA
1 shared publication - Roy I. Davidovitch
NYU Hospital for Joint Diseases, Orthopaedic Surgery, 301 E. 17th St. Suite 1402, New York, NY 10001, USA
1 shared publication
Latest Publications
- 1 January 2013
- Vol. 71 (2) , 144-51
Tibial plateau fractures with and without meniscus tear--results of a standardized treatment protocol.
The purpose of this study was to determine what patient and injury factors are associated with the presence of a meniscus tear in tibial plateau fractures. We also sought to compare functional outcome, pain scores, and range of motion between patient groups with and without meniscal injury. A total of 99 patients with 101 acute tibial plateau fractures were included in the study cohort. Patients were divided into two groups: those with and without meniscus tears at the time of initial injury. Statistical analysis with Student's t-test for continuous variables and chi square test for categorical variables was performed to compare those with and without a meniscal tear. Logistic regression was performed to identify the variables that predicted the presence of a meniscus tear and repeated ANOVA measures were used to assess functional outcome scores. Fifty-four patients with 56 tibial plateau fractures (55%) were found to have an associated meniscal tear. The average amount of joint depression in this group was 12.3 mm (range: 2.0 to 29.5 mm). The remaining 45 patients with 45 fractures (45%) had an average depression of 5.4 mm (range: 0.0 to 12.8 mm). Degree of tibial plateau depression was the only significant predictor of meniscal injury. Our findings suggest that amount of depression in tibial plateau fractures is a significant predictor of the occurrence of a meniscus tear with an odds ratio of 1.36. We also found no significant difference in the functional outcome, pain scores, and knee range of motion between the group with and without meniscus tears at the longest follow-up interval. These findings suggest that acute repair of meniscal injury following traumatic fracture of the tibial plateau could produce functional results similar to those patients that did not sustain a meniscus tear.
- 1 January 2013
- Vol. 71 (2) , 144-51
Tibial plateau fractures with and without meniscus tear--results of a standardized treatment protocol.
The purpose of this study was to determine what patient and injury factors are associated with the presence of a meniscus tear in tibial plateau fractures. We also sought to compare functional outcome, pain scores, and range of motion between patient groups with and without meniscal injury. A total of 99 patients with 101 acute tibial plateau fractures were included in the study cohort. Patients were divided into two groups: those with and without meniscus tears at the time of initial injury. Statistical analysis with Student's t-test for continuous variables and chi square test for categorical variables was performed to compare those with and without a meniscal tear. Logistic regression was performed to identify the variables that predicted the presence of a meniscus tear and repeated ANOVA measures were used to assess functional outcome scores. Fifty-four patients with 56 tibial plateau fractures (55%) were found to have an associated meniscal tear. The average amount of joint depression in this group was 12.3 mm (range: 2.0 to 29.5 mm). The remaining 45 patients with 45 fractures (45%) had an average depression of 5.4 mm (range: 0.0 to 12.8 mm). Degree of tibial plateau depression was the only significant predictor of meniscal injury. Our findings suggest that amount of depression in tibial plateau fractures is a significant predictor of the occurrence of a meniscus tear with an odds ratio of 1.36. We also found no significant difference in the functional outcome, pain scores, and knee range of motion between the group with and without meniscus tears at the longest follow-up interval. These findings suggest that acute repair of meniscal injury following traumatic fracture of the tibial plateau could produce functional results similar to those patients that did not sustain a meniscus tear.
- 1 December 2011
- Vol. 77 (6) , 802-8
The percutaneous use of a pointed reduction clamp during intramedullary nailing of distal third tibial shaft fractures.
The purpose of this retrospective chart and radiographic review is to describe an effective reduction technique during intramedullary nailing of distal metaphyseal tibia fractures with the use of a pointed percutaneous clamp. Between 2007 and 2010, 100 patients who sustained 102 tibia fractures were definitively treated with an intramedullary nail at one of two medical centers. Diaphyseal fractures and injuries with an associated disruption of the distal tibiofibular joint were excluded from our study. A total of 27 patients with 27 distal metaphyseal tibia fractures (OTA types 42-A, 43-A, and 43-B) were included. All 27 patients underwent IM nailing of their fractures with anatomic reduction achieved using a percutaneously placed pointed reduction clamp prior to insertion of the IM implant. Fracture alignment and angular deformity was assessed using goniometric measurement functions on the PACS system (GE, Waukeshau, WI) obtained from preoperative and postoperative anteroposterior and lateral images for all subjects. Malalignment was defined as more than 5 degrees of angulation in any plane. Fourteen of the fractures were classified as OTA 42-A, 9 were OTA 43-A, and 4 were OTA 43-B. Analysis of post-closed reduction, preoperative anteroposterior radiographs revealed a mean of 7.9 degrees of coronal plane (range: 0.9 degrees-26 degrees) angulation. Post closed reduction preoperative lateral radiographs revealed a mean of 6.8 degrees sagittal plane (range: 0 degrees-24.6 degrees) angulation. Postoperative anteroposterior and lateral radiographs showed the distal segment returned to its anatomical alignment with a mean angulation of 0.5 degrees (range, 0 degrees-3.5 degrees) and 0.7 degrees (range, 0 degrees-4.2 degrees) of varus/ valgus and apex anterior/posterior angulation, respectively. These results showed an acceptable postopertative alignment in all 27 distal third fractures. No intra-operative or postoperative complications were noted in the study group. This study suggests that the use of percutaneous clamps during intramedullary nailing of distal metaphyseal tibia fractures is an easily-reproducible and effective method of reduction with no associated intraoperative complications.
- 1 December 2011
- Vol. 77 (6) , 802-8
The percutaneous use of a pointed reduction clamp during intramedullary nailing of distal third tibial shaft fractures.
The purpose of this retrospective chart and radiographic review is to describe an effective reduction technique during intramedullary nailing of distal metaphyseal tibia fractures with the use of a pointed percutaneous clamp. Between 2007 and 2010, 100 patients who sustained 102 tibia fractures were definitively treated with an intramedullary nail at one of two medical centers. Diaphyseal fractures and injuries with an associated disruption of the distal tibiofibular joint were excluded from our study. A total of 27 patients with 27 distal metaphyseal tibia fractures (OTA types 42-A, 43-A, and 43-B) were included. All 27 patients underwent IM nailing of their fractures with anatomic reduction achieved using a percutaneously placed pointed reduction clamp prior to insertion of the IM implant. Fracture alignment and angular deformity was assessed using goniometric measurement functions on the PACS system (GE, Waukeshau, WI) obtained from preoperative and postoperative anteroposterior and lateral images for all subjects. Malalignment was defined as more than 5 degrees of angulation in any plane. Fourteen of the fractures were classified as OTA 42-A, 9 were OTA 43-A, and 4 were OTA 43-B. Analysis of post-closed reduction, preoperative anteroposterior radiographs revealed a mean of 7.9 degrees of coronal plane (range: 0.9 degrees-26 degrees) angulation. Post closed reduction preoperative lateral radiographs revealed a mean of 6.8 degrees sagittal plane (range: 0 degrees-24.6 degrees) angulation. Postoperative anteroposterior and lateral radiographs showed the distal segment returned to its anatomical alignment with a mean angulation of 0.5 degrees (range, 0 degrees-3.5 degrees) and 0.7 degrees (range, 0 degrees-4.2 degrees) of varus/ valgus and apex anterior/posterior angulation, respectively. These results showed an acceptable postopertative alignment in all 27 distal third fractures. No intra-operative or postoperative complications were noted in the study group. This study suggests that the use of percutaneous clamps during intramedullary nailing of distal metaphyseal tibia fractures is an easily-reproducible and effective method of reduction with no associated intraoperative complications.