MDMichèle Detry-Morel

Michèle Detry-Morel

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michèle Detry-Morel has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 January 2013
      • No. 322,p. 91-7

    The range of the waveform score of the ocular response analyzer (ora) in healthy subjects.

    by M Vantomme, S Pourjavan, M Detry-Morel

    The waveform score (WS) indicates the reliability of each intraocular pressure (lOP) measurement signal performed with the Ocular Response Analyzer (ORA, Reichert). We aimed to assess i) the range of waveform score in IOP measurements with ORA in healthy subjects and to ii) identify a cut-off WS value under which an ORA measurement should be discarded. Prospective study including three ORA IOP measurements performed in the right eye of 80 healthy normal subjects. The different WS were recorded and the highest WS of the three measurements was analysed. ANOVA test was used to assess variance in repeated measurements. Mean age of 80 subjects was 46.7+/-15.6 years. Mean WS of the first IOP measurement was 4.8+/-2.0 and 4.8+/-1.7 and 5.0+/-1.9 respectively for the second and third measurements (p= 0.74). Mean WS of the analysed 240 signals (3 measurements per eye) was 4.9+/-1.9 (range: 1.2-9.5). The mean value of all the highest values per eye was 6.2+/-1.8 (range: 2.9 -9.5 and was significantly higher than the mean WS of the 240 signals together (p 7.5 could be considered as sufficient. If this score cannot be reached after three consecutive measurements, the signal with the highest WS should be selected.


  • Comparison of the corneal biomechanical properties with the Ocular Response Analyzer® (ORA) in African and Caucasian normal subjects and patients with glaucoma

    by Michèle Detry‐Morel, Jacques Jamart, Frédéric Hautenauven, Sayeh Pourjavan

    : Purpose:  To compare corneal hysteresis (CH) and corneal resistance factor (CRF) measured with the Ocular Response Analyzer® tonometer (ORA) between (i) African normals and treated primary open‐angle glaucoma (POAG) patients and (ii) between normals and treated POAG Caucasians. To analyse the correlation of CH and CRF with visual field (VF) defects in the two groups.Methods:  This comparative study included 59 African (29 (POAG), 30 normals) and 55 Caucasians (30 POAG and 25 normals) subjects. Goldmann applanation tonometry (GAT) and ORA measurements were performed in a randomized sequence. Visual field was tested with the Swedish interactive threshold algorithms standard strategy of the Humphrey perimeter. Hoddap classification was used to estimate the severity of VF defects.Results:  Primary open‐angle glaucoma Africans were younger than POAG Caucasians (p < 0.001). Goldmann applanation tonometry and central corneal thickness (CCT) did not differ significantly between the four subgroups. African normals had lower CH than Caucasian controls (p < 0.001). CH was 9.2 ± 1.1 and 8.3 ± 1.7 mmHg respectively in POAG Caucasians and Africans (p < 0.001). African controls had higher ORA corneal‐compensated intraocular pressure (IOPcc) than Caucasian controls (p < 0.001). Primary open‐angle glaucoma Africans had higher IOPcc values than Caucasian POAGs (p < 0.001). CH and IOPcc were associated with race (p < 0.001) but not with CCT. Based on mean deviation values (MD), POAG Africans had more severe VF defects. CH was correlated with MD (r = 0.442; p = 0.031) and severity of VF defects only in POAG Africans (r = −0.464; p = 0.013).Conclusions:  African normal subjects and POAG patients had an altered CH, which is associated with a significant underestimation of GAT IOP. This may potentially contribute to the earlier development and greater severity of glaucoma damage in Africans compared with Caucasians at diagnosis.


  • Evaluation of Corneal Biomechanical Properties with the Reichert Ocular Response Analyzer

    by Michèle Detry-Morel, Jacques Jamart, Saveh Pourjavan

    Purpose: TO compare corneal hysteresis (CH) and corneal resistance factor (CRF) measured with the Ocular Response Analyzer (ORA) in patients with primary open-angle glaucoma (POAG), patients with ocular hypertension (OHT), and normal subjects (NL); and to assess correlations of CH and CRF with corneal-compensated intraocular pressure (IOPcc), Goldmann applanation tonometry (GAT), glaucoma type, central corneal thickness (CCT), previous filtering procedure, and antiglaucoma medications. Methods: A total of 108 POAG, 22 OHT, and 24 NL were enrolled in this observational study Goldmann applanation tonometry and ORA were performed in a randomized sequence followed by pachymetry One eye per subject was selected at random for analysis. Chi-square, Wilcoxon, and Kruskal-Wallis tests were used for comparison and Spearman coefficient for assessing correlations. Results: Mean CH and CRF were significantly lower in POAG than in OHT and NL. Ocular Response Analyzer IOPcc overestimated IOP compared to GAT only in POAG. This difference increased with higher GAT. Goldmann applanation tonometry and IOPcc were correlated. Corneal hysteresis was negatively correlated with age in POAG. Corneal resistance factor and CH were positively correlated with CCT in POAG and OHT. Unlike CRF, CH was not correlated with GAT in POAG and OHT. Corneal-compensated intraocular pressure was not correlated with CCT. Difference between GAT and IOPcc was not CCT dependent. Corneal hysteresis and CRF were comparable in POAG and NTG, un-changed after filtering procedure. Corneal hysteresis was not altered by topical medications. Corneal resistance factor was significantly lower in treated eyes and those receiving prostaglandin analogues with no correlation with the treatment duration. Conclusions: Patients with glaucoma seem to have distinctive corneal biomechanical properties compared to OHT and NL. They may be influenced by many other unknown subparameters.


    • 1 January 2010
      • No. 316,p. 87

    Haab's striae.

    by M Detry-Morel

    • 1 January 2010
      • No. 316,p. 63-84

    [The six keys of the monitoring of the glaucoma patient].

    by M Detry-Morel

    Treatment of glaucoma aims at preserving the visual function and the Quality of Life (QoL) of the patients. To slow down the progression of the disease, the IOP should be decreased to a level where the risk of further deterioration is reduced to a minimum. Rates of progression vary between patients. Detection of glaucoma progression should be based on the assessment of structure and function. When making a treatment plan, one should take into consideration the rate of progression and the impact of visual field deterioration on the QoL. Therefore, a careful and reliable baseline examination is crucial. Furthermore, yearly documentation of the optic disc and frequent examinations of the visual field, especially during the first two years of follow-up, are mandatory to evaluate how aggressive the treatment should be. Slowing down progression of the disease is closely related to a good communication with the patient, the quality of the information provided, and the tolerance of the medications, all keys to a good adherence. Other risk factors than IOP should be looked for and treated if possible, especially when worsening of glaucoma damage is observed despite apparently good IOP control and compliance. Modern monitoring of the glaucoma patient can be summarized in six keys. Current limitations of this approach will be briefly discussed.

    • 1 January 2008
      • No. 308,p. 21-8

    Micropulse diode laser (810 nm) versus argon laser trabeculoplasty in the treatment of open-angle glaucoma: comparative short-term safety and efficacy profile.

    by M Detry-Morel, F Muschart, S Pourjavan

    Prospective, comparative, randomised study aiming at assessing the safety and the intraocular pressure (IOP) lowering effect of Micropulse Diode Laser Trabeculoplasty (810nm)(MDLT) and Argon Laser Trabeculoplasty in patients with open angle glaucoma. 26 patients (mean age=67 years) were randomly assigned to undergo either MDLT (16 eyes) (66 applications, 100 msec, 0.6 mJ/pulse, 300 microm) or ALT (15 eyes) over 180 degrees. In 5 patients, MDLT was done in one eye and ALT in the other eye. Patients were followed for early IOP spikes and anterior segment inflammation. IOP was recorded at 1 day, 1 week, 1 and 3 months and 3 month intervals thereafter. Both groups were well-matched for age, glaucoma type, previous laser or surgical procedure, pre-treatment meds. Mean follow-up was 5.2 +/- 1.7 months for MDLT and 5.5 +/- 2.3 in ALT (p>0.05). Mean pre-treatment IOP was 20.7 +/- 3.8 mmHg and 21.6 +/- 4.2 mmHg in ALT respectively (p>0.05). Mean IOP was significantly reduced compared to the pre-treatment level in both groups at the different visits (p or =20% compared to the baseline IOP observed in 35.7% in MDLT versus 50% in ALT (p=0.03). At 3 months, the mean number of meds was significantly lower in MDLT (2.1 +/- 0.8) than in ALT (2.8 +/- 0.7) (p=0.03). MDLT was uneventful in 100% of patients with no thermal pain and no uncomfortable laser flashes. Anterior segment inflammation was absent or mild in both procedures. MDLT was associated with early moderate IOP spike in one eye with POAG. At 3 months, Micropulse diode laser trabeculoplasty induced significantly less IOP reduction than ALT. The percentage of eyes with an IOP drop > or =20% was also significantly lower with diode laser than with argon laser trabeculoplasty. MDLT induced minimal anterior segment inflammation and seemed to exhibit a good safety profile. Its IOP efficacy should be still confirmed on a larger sample size and by modifying the treatment parameters.


    • 1 January 2006
      • No. 300,p. 43-54

    Comparative safety profile between "modern" trabeculectomy and non-penetrationg deep sclerectomy.

    by M Detry-Morel, S Pourjavan, M B Detry

    To compare the incidence and the severity of short-and medium-term complications following "modern" trabeculectomy (mTRAB) with non-penetrating deep sclerectomy (NPDS). Comparative retrospective nonrandomized study including 65 eyes (55 patients) (mean age: 68.6 years) with medically uncontrolled glaucoma. mTRAB was performed in 43 eyes, NPDS in 22 eyes. mTRAB was performed according to a slightly modified P.T. Khaw protocol. NPDS procedures were done according to Kozlov's and Mermoud's technique with SKGEL implant in 18/22 eyes. Intraoperative antimetabolites (AMETAB) were given in 25 eyes (58%) in the mTRAB and 17 (77%) in the NPDS (p>0.05). Mean follow-up was longer in NPDS (10.7+/-5.5 months) than in mTRAB (8.5+/-3.4 months) (p0.05). Peroperatively, mTRAB were uneventful in 86% vs 90% of NPDS. 1st month postop complications occurred in 60.4% in mTRAB and 77.2% in NPDS (P>0.05). Most of them were minor and transient in both surgeries. Postop early anterior chamber inflammation was mild to moderate in all cases. The incidence of wound leaks (21% in the mTRAB group and 18% in the NPDS group) and hyperfiltration related complications (14% and 13.6% respectively in the mTRAB and NPDS group) were comparable between the two procedures (p > 0.05). Intraoperative antimetabolite application was not associated with an increased rate of postoperative hyperfiltration related complications. Scarring of filtration blebs had concerned a lower percentage of mTRAB eyes (19%) than the NPDS (36%). The number for 5-FU injections was less - although not significantly - in the mTRAB than in the other group (18.6% in mTRAB versus 41% in NPDS (p=0.05). Late complications were not observed in the mTRAB group. Iris prolapse associated with increased IOP occurred in 3 of the 22 NPDS procedures (13.6%). Final mean visual acuity was unchanged compared with preop value and was similar between the 2 groups (p>0.05). Diffuse, mildly vascularized filtration blebs were observed in 84% in mTRAB and 64% in DS (p>0.05). Mean IOP significantly decreased from 24.8+/-8.3 mm Hg to 13.4+/-4,3 mm Hg in mTRAB and from 25.1+/-6.5 mm Hg to 14.7+/-4.6 mm Hg in DS (p> 0.05). It was not different between the 2 groups with and without AMETAB augmentation. 70% of the mTRAB achieved a final IOP < or = 15 mmHg vs 41% in NPDS (p0.05). Whether surgery was augmented with intraoperative antimetabolite or not, mTRAB revealed as a priority to be associated with comparable and even less complications than deep sclerectomy. Owing to the limitations of our study and until further confirmation, our results have suggested that mTRAB was associated with a slightly more important IOP reduction as well as higher success rates than NPDS.