Ying Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ying Huang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Guonan Chen
2 shared publicationsXiaofeng Li
College of Chemistry and Chemical Engineering Fujian Normal University Fuzhou Fujian 350007 China
2 shared publicationsChunrong Zhan
1 shared publicationCuiyun Zhang
College of Chemistry and Chemical Engineering Fujian Normal University Fuzhou Fujian 350007 China
1 shared publication- Guonan Chen
Ministry of Education Key Laboratory of Analysis and Detection Technology for Food Safety (Fuzhou University)
1 shared publication Jia Xiao
College of Chemistry and Chemical Engineering, Fujian Normal University, Fuzhou 350007, China
1 shared publication
Latest Publications
- 18 January 2017
- Published by Wiley in Electroanalysis
- Vol. 29 (4) , 1141-1146
Voltammetric Separation and Determination of Glutathione and L‐tyrosine with Chlorogenic Acid as an Electrocatalytic Mediator
A novel and sensitive voltammetric method was proposed for separation and determination of glutathione (GSH) and L‐tyrosine (Tyr) at acetylene black and chitosan modified glassy carbon electrode (AB‐CS/GCE). By introducing chlorogenic acid (CGA) as a new electrocatalytic mediator, GSH could be detected at much lower potential with symmetric peak shape. Acetylene black and chitosan composite served as current signal amplifier for sensitive detection. The electrochemical behavior of GSH and Tyr in the presence of CGA was studied at AB‐CS/GCE and complete separation of anodic peaks was achieved. Under the optimum conditions, the electrocatalytic oxidation peak current of GSH showed a linear dependence on its concentration in the ranges of 2.0×10−7‐4.0×10−5 M with the detection limit of 5.8×10−8 M (S/N=3), while the oxidation peak current of Tyr was linear to its concentration from 2.5×10−6 to 4.3×10−4 M with the detection limit of 9.2×10−7 M (S/N=3) by differential pulse voltammetry (DPV). The established method has been applied to the simultaneous determination of GSH and Tyr in human urine with satisfactory results.
- 18 January 2017
- Published by Wiley in Electroanalysis
- Vol. 29 (4) , 1141-1146
Voltammetric Separation and Determination of Glutathione and L‐tyrosine with Chlorogenic Acid as an Electrocatalytic Mediator
A novel and sensitive voltammetric method was proposed for separation and determination of glutathione (GSH) and L‐tyrosine (Tyr) at acetylene black and chitosan modified glassy carbon electrode (AB‐CS/GCE). By introducing chlorogenic acid (CGA) as a new electrocatalytic mediator, GSH could be detected at much lower potential with symmetric peak shape. Acetylene black and chitosan composite served as current signal amplifier for sensitive detection. The electrochemical behavior of GSH and Tyr in the presence of CGA was studied at AB‐CS/GCE and complete separation of anodic peaks was achieved. Under the optimum conditions, the electrocatalytic oxidation peak current of GSH showed a linear dependence on its concentration in the ranges of 2.0×10−7‐4.0×10−5 M with the detection limit of 5.8×10−8 M (S/N=3), while the oxidation peak current of Tyr was linear to its concentration from 2.5×10−6 to 4.3×10−4 M with the detection limit of 9.2×10−7 M (S/N=3) by differential pulse voltammetry (DPV). The established method has been applied to the simultaneous determination of GSH and Tyr in human urine with satisfactory results.
- 20 September 2012
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Chromatography
- Vol. 30 (9) , 951-956
Analysis of phthalate esters in plastic-packaging bags by on-line sample stacking-microemulsion electrokinetic chromatography
Two convenient, effective, and reproducible methods using microemulsion electrokinetic chromatography (MEEKC)-normal stacking mode (NSM) and reversed electrode polarity stacking mode (REPSM) were developed for the on-line sample stacking of phthalate esters (PAEs). REPSM coupled with MEEKC increased the sensitivity of 937.5 to 7,143 times for four PAEs compared to the conventional MEEKC. The separating conditions in the MEEKC method were studied, and many factors influencing the two sample stacking processes were investigated in detail. The optimum sample matrices for the two stacking methods were as follows: 30 mmol/L sodium cholate (SC) and 30.0 mmol/L borate (pH 8.5). Additionally, sample injections as large as 3.45 kPa x 40 s and 3.45 kPa x 90 s were applied for NSM-MEEKC and REPSM-MEEKC, respectively. The linear relationship and reproducibility were also examined. Under the optimum conditions, the detection limits (S/N = 3) of the PAEs were in the ranges of 0.021 - 0.33 mg/L and 0.7 - 4 microg/L for NSM-MEEKC and REPSM-MEEKC, respectively. The proposed REPSM-MEEKC has been successfully applied to determine PAEs in plastic-packaging bags, and the spiked recoveries were in the range of 89.1% - 105.6% with satisfactory results.
- 20 September 2012
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Chromatography
- Vol. 30 (9) , 951-956
Analysis of phthalate esters in plastic-packaging bags by on-line sample stacking-microemulsion electrokinetic chromatography
Two convenient, effective, and reproducible methods using microemulsion electrokinetic chromatography (MEEKC)-normal stacking mode (NSM) and reversed electrode polarity stacking mode (REPSM) were developed for the on-line sample stacking of phthalate esters (PAEs). REPSM coupled with MEEKC increased the sensitivity of 937.5 to 7,143 times for four PAEs compared to the conventional MEEKC. The separating conditions in the MEEKC method were studied, and many factors influencing the two sample stacking processes were investigated in detail. The optimum sample matrices for the two stacking methods were as follows: 30 mmol/L sodium cholate (SC) and 30.0 mmol/L borate (pH 8.5). Additionally, sample injections as large as 3.45 kPa x 40 s and 3.45 kPa x 90 s were applied for NSM-MEEKC and REPSM-MEEKC, respectively. The linear relationship and reproducibility were also examined. Under the optimum conditions, the detection limits (S/N = 3) of the PAEs were in the ranges of 0.021 - 0.33 mg/L and 0.7 - 4 microg/L for NSM-MEEKC and REPSM-MEEKC, respectively. The proposed REPSM-MEEKC has been successfully applied to determine PAEs in plastic-packaging bags, and the spiked recoveries were in the range of 89.1% - 105.6% with satisfactory results.
- 14 June 2012
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 137 (18) , 4335-4342
Electrochemical behavior of o-sec-butylphenol at glassy carbon electrode modified with multiwalled carbon nanotubes and 1-butyl-3-methylimidazolium hexafluorophosphate
A sensitive electrochemical sensor based on immobilized multiwalled carbon nanotubes (MWCNTs) and 1-butyl-3-methylimidazolium hexafluorophosphate (BMIM·PF6) on a glassy carbon electrode (GCE) for o-sec-butylphenol (osBP) was proposed. The electro-oxidation behavior was studied, the experimental conditions were optimized and kinetic parameters were calculated. The results indicated that this electrochemical sensor has the advantages of fast electron-transfer rate, minimal fouling of electrodes, high sensitivity and stability for o-sec-butylphenol. Upon comparison with a glassy carbon electrode, this senor would effectively minimize the over-potential and increase the electrochemical response to o-sec-butylphenol. Under the optimum conditions, the peak current was linear to the osBP concentration range from 1 × 10−7 to 2.5 × 10−5 M with the detection limit of 8.65 × 10−9 M (S/N = 3). The proposed method was applied to the determination of spiked water samples with satisfactory results.
- 14 June 2012
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 137 (18) , 4335-4342
Electrochemical behavior of o-sec-butylphenol at glassy carbon electrode modified with multiwalled carbon nanotubes and 1-butyl-3-methylimidazolium hexafluorophosphate
A sensitive electrochemical sensor based on immobilized multiwalled carbon nanotubes (MWCNTs) and 1-butyl-3-methylimidazolium hexafluorophosphate (BMIM·PF6) on a glassy carbon electrode (GCE) for o-sec-butylphenol (osBP) was proposed. The electro-oxidation behavior was studied, the experimental conditions were optimized and kinetic parameters were calculated. The results indicated that this electrochemical sensor has the advantages of fast electron-transfer rate, minimal fouling of electrodes, high sensitivity and stability for o-sec-butylphenol. Upon comparison with a glassy carbon electrode, this senor would effectively minimize the over-potential and increase the electrochemical response to o-sec-butylphenol. Under the optimum conditions, the peak current was linear to the osBP concentration range from 1 × 10−7 to 2.5 × 10−5 M with the detection limit of 8.65 × 10−9 M (S/N = 3). The proposed method was applied to the determination of spiked water samples with satisfactory results.
- 1 November 2010
- Vol. 28 (11) , 1084-8
[Determination of three adrenergic drugs using capillary electrophoresis with amperometric detection].
A method for the determination of three adrenergic drugs, including phenylephrine hydrochloride (PHE), metaraminol bitartrate (MR) and isoprenaline hydrochloride (IP), was developed using capillary electrophoresis with amperometric detection. The detection potential of working electrode was 0.950 V versus the reference electrode of Ag/AgCl. At the applied voltage of 18 kV, the three analytes were completely separated within 18 min in 50 mmol/L borate buffer (pH 10.00) with the injection time of 10 s. Good linear relationships were obtained for all the three analytes in the range of 2-100 micromol/L. The detection limits for PHE, MR and IP were 0.8, 0.8 and 1.0 micromol/L, respectively. The proposed method was applied to the analysis of some injection drugs, and the results were satisfactory.
- 1 November 2010
- Vol. 28 (11) , 1084-8
[Determination of three adrenergic drugs using capillary electrophoresis with amperometric detection].
A method for the determination of three adrenergic drugs, including phenylephrine hydrochloride (PHE), metaraminol bitartrate (MR) and isoprenaline hydrochloride (IP), was developed using capillary electrophoresis with amperometric detection. The detection potential of working electrode was 0.950 V versus the reference electrode of Ag/AgCl. At the applied voltage of 18 kV, the three analytes were completely separated within 18 min in 50 mmol/L borate buffer (pH 10.00) with the injection time of 10 s. Good linear relationships were obtained for all the three analytes in the range of 2-100 micromol/L. The detection limits for PHE, MR and IP were 0.8, 0.8 and 1.0 micromol/L, respectively. The proposed method was applied to the analysis of some injection drugs, and the results were satisfactory.