    Comparison of minimal fresh gas requirements of baby enclosed afferent reservoir and Jackson Rees anesthetic circuit for general anesthesia in spontaneously breathing children.

    by Sunchai Theerapongpakdee, Thepakorn Sathitkamrnmanee, Sirirat Tribuddharat, Nonthida Rojanapithayakorn, Kanchana Uppan, Cattleya Thongrong, Piyaporn Bunsangcharoen

    The authors compared the baby enclosed afferent reservoir (Baby EAR) with the Jackson-Rees (JR) anesthesia circuit for the minimal fresh gas flow (FGF) requirement with no and clinically acceptable rebreathing in spontaneous breathing anesthesia among pediatric patients. The present study was a randomized crossover study. Twenty patients, weighing 5 to 20 kg with ASA physical status I-II were enrolled. They were allocated to group 1 (EAR-JR) starting with Baby EAR then switching to JR or group 2 (JR-EAR), reversedpattern. After induction and intubation, anesthesia was maintainedwith a N2O/O2 combination with sevoflurane 1 to 3% and fentanyl. Starting with the first circuit, all patients were spontaneously ventilated with FGF 500 mL/kg/min for 10 minutes, and then gradually decreased by 50 mL/kg/min every five minutes. End-tidal CO2 (ETCO) and inspired minimum CO2 (imCO) were recorded until rebreathing (imCO2 >2 mmHg) occurred and continued until rebreathing was not clinically acceptable (imCO2 >6 mmHg). The anesthesia breathing circuit was switched and the procedure repeated. The minimal FGF at no rebreathing of Baby EAR and JR were 192.5±76.6 and 347.5±108.2 mL/kg/min; p<0.001. At acceptable rebreathing, the values were 117.5±46.7 and 227.6±90.6 mL/kg/min; p< 0. 001. Baby EAR can be used safely, effectively, and requires less FGF than JR in pediatric anesthesia in patients weighing 5 to 20 kg.


    • 1 November 2010
      • Vol. 93  (11) , 1284-7

    Baby EAR circuit: a clinical determination of optimal fresh gas flow in spontaneous breathing anesthesia.

    by Sunchai Theerapongpakdee, Piyaporn Bunsangjaroen, Duenpen Horatanaruang, Thanyarat Phanpanusit, Chutima Asava-Aree, Kanchana Uppan

    Baby EAR circuit is a new modified enclosed afferent reservoir anesthetic breathing system invented to use in pediatric patients. By following His Majesty the King of Thailand's self-sufficiency philosophy, the circuit is simplymade of low-cost and easy-to-find materials in the operating room. Investigate clinical use of the circuit and to find the optimal fresh gas flow in spontaneous breathing anesthesia. A prospective descriptive study was conducted in pediatric patients, who weighed 5-20 kg, anesthetized for surgery and divided into three groups of body weight: groups I (5 - or = 2.5 LPM

    • 1 May 2009
      • Vol. 92  (5) , 667-71

    A clinical determination of optimal fresh gas flow in a baby EAR circuit.

    by Sunchai Theerapongpakdee, Thanyathorn Phanpanusit, Duenpen Horatanaruang, Piyaporn Bunsangjaroen, Prapapan Limpkulwathanaporn, Maneerut Thananun, Duangthida Nonlhaopol

    Baby EAR circuit is a new modified enclosed afferent reservoir anesthetic breathing system for pediatric patients. By following His Majesty the King of Thailand's self-sufficiency philosophy, the circuit is simple and made of low-cost and easy-to-find materials found in the operating room. This present study was to investigate clinical use of the circuit and to find the optimal fresh gas flow in clinical setting. A prospective descriptive study was conducted in pediatric patients, weighed 5-20 kg, anesthetized for surgery. The Baby EAR breathing circuit was used for general anesthesia with endotracheal tube and control ventilation. Different fresh gas flow of 3, 2.5, 2 and 1.5 liter per minute (LPM) was used consecutively. The authors recorded end-tidal carbon dioxide (EtCO2) and mean inspiratory carbon dioxide (ImCO2) while using fresh gas flow at 3, 2.5, 2, and 1.5 LPM. EtCO2 of 35-45 mmHg and ImCO2 of < 6 mmHg were considered clinically acceptable. Fifty patients were enrolled. Mean value (95% CI) of EtCO2 at fresh gas flow rate of 1.5, 2, 2.5, and 3 LPM were 39.6 (39.2, 40.9), 36.7 (35.5, 37.8), 35.4 (34.3, 36.4), and 35.4 (34.3, 36.4) mmHg respectively. Mean value (95% CI) of ImCO2 at fresh gas flow rate of 1.5, 2, 2.5, and 3 LPM were 4.0 (3.0, 4.9), 2.4 (1.7, 3.0), 1.8 (0.9, 2.6), and 1.3 (0.9, 1.7) mmHg respectively. Percentage of patients (95% CI) who had clinically acceptable EtCO2 and ImCO2 at fresh gas flow rate of 1.5, 2, 2.5, and 3 LPM were 70% (56.2, 80.9), 92% (81.2, 96.8), 98% (89.5, 99.6), and 100% (92.9, 100) respectively. No patients had serious complications. Baby EAR circuit can be made economically and used safely for general anesthesia with control ventilation in pediatric patients weighing 5 to 20 kg at optimal fresh gas flow of 3 LPM.