    Development of a Portable Uroflowmeter Employing Flushable Urine Collection Containers

    by Yusuke Onishi, Keisuke Shichitani, Kazuki Nakajima

    An increasing number of individuals in aging populations are affected by urination disorders such as benign prostatic hyperplasia and overactive bladder. Bladder diaries are widely used in the diagnosis of these disorders. Patients record the time of urination and voided volume (VV) for 3 consecutive days in their bladder diaries. A urine collection container is required for VV measurement. Inappropriate disposal or cleaning of instruments after use can result in the transmission of infection. In addition, self-recording of bladder diaries often have problems such as inaccurate recording or missing entries of urinary output. To address these issues, we developed a water-soluble paper urine collection container that can be flushed down the toilet. This system was also developed to measure VV and urinary flow rate parameters. VV, maximum urinary flow rate (Qmax), and average flow rate (Qave) were estimated based on the increase in capacitance between the electrodes placed on the exterior of the container. In a basic experiment, 0.9% saline solution was used as pseudo-urine. The relationship between the volume of pseudo-urine and change in capacitance (Δx) exhibited a strong linear correlation (R2 > 0.99). A correction factor (k ≈ 1.31) was applied to account for the difference in dielectric constant between urine and saline solution. The conversion from Δx to VV was determined based on the results of the basic experiment. In a urination measurement experiment, five young males (23 ± 1 years) without symptoms of urination disorders participated. Each subject urinated ten times. Simultaneous measurements were obtained using the proposed system and a medical uroflowmeter (PicoFlow2, MEDICA S.p.A., MO, Italy). The mean errors (mean ± SD) for VV, Qmax, and Qave were 14.9 ± 41.8 mL, 2.5 ± 6.0 mL/s, and 2.0 ± 2.6 mL/s, respectively. The mean absolute percent error for VV, Qmax, and Qave were 14.1%, 15.9% and 19.9%, respectively. Paired t-tests (significance level, p < 0.01) showed no significant differences between the two measurement methods for any of the parameters. Bland-Altman analysis revealed no systematic error between the proposed system and the medical uroflowmeter for any of the items. The VV, Qmax, Qave measured using the proposed system agree well with those measured using a medical uroflowmeter. This system can be expected to be a hygienic and portable uroflowmeter that can contribute to automated bladder diary recording.

  • Open Access

    Basic Study on Improving the Measurement Accuracy of Urine Absorption Volume in a Diaper Sensor System using a 3-Dimensional Accelerometer for Posture Detection

    by Kaito Nakane, Keisuke Shichitani, Kazuki Nakajima

    In Japanese nursing homes, diapers are typically changed at scheduled times each day. However, unnecessary changes may occur when no urination has taken place or when the diaper retains sufficient absorptive capacity. These unnecessary changes increase caregiver workload and contribute to higher costs due to the disposal of unused diapers. Monitoring urination timing and urine absorption volume can help ensure that diapers are changed only when needed, thereby improving care efficiency and reducing costs. We developed a diaper sensor system capable of detecting urination timing and measuring urine absorption volume. The system consists of comb-shaped electrodes connected to a microcomputer, with the electrodes affixed to the outside of the diaper. Urine absorption volume is derived from changes in capacitance measured between the electrodes. The previous system did not consider postures when measuring urine absorption volume. This study demonstrates the necessity of posture detection for measuring urine absorption volume and proposes a new diaper sensor system that measures urine absorption volume using posture detected by an integrated accelerometer. In phantom experiments, the proposed system reduced the mean absolute percentage error (MAPE) from 30% (previous system) to 10%, and posture detection using the accelerometer achieved 100% accuracy, demonstrating the necessity of posture detection for measuring urine absorption volume. To evaluate the practicality of the proposed system and compare its accuracy in measuring urine absorption volume with that of the previous system, a healthy adult male volunteer wore the sensor-attached diaper and accelerometer. After resting for 1 h, the subject urinated in one of three postures-supine, sitting, or 90-degree lateral-each tested eight times. The proposed system reduced the MAPE from 35% (previous) to 23%, demonstrating improved measurement accuracy in actual use scenarios.

  • Open Access

    Evaluation of the Measurement Accuracy of a Scale-type Uroflowmeter with Two Other Types of Uroflowmeters, Excluding the Impeller Type, in Young and Older Males

    by Yoji Ando, Tetsuya Fujita, Kazuki Nakajima

    Urinary parameters such as voided volume and flow rate are crucial for diagnosing dysuria. Conventional uroflowmeters (UFMs) measure urinary flow based on weight changes or impeller rotation. However, these devices may present hygiene-related issues due to direct contact with urine, and the results may not accurately represent normal urination because of differences in posture and environment. To address these issues, we developed a scale-type UFM that utilizes weight loss during urination to measure flow. In a previous study, we reported that the accuracy of the scale-type UFM was comparable to that of three medical UFMs when measured in young males. In that study, participants urinated into an impeller-type UFM (Freeflow®), and urine ejected from the Freeflow was collected in a weighted UFM (P-Flowdiary®) cup placed over another weighted UFM (PicoFlow2®). However, as measurements using these medical UFMs were performed simultaneously, Freeflow, which was the first to contact the urine, may have reduced the flow rate and retained some urine. Thus, the present study aimed to determine whether the urinary flow rate slowed by Freeflow is less than the measurement error in young males (21.9 ± 1.0 years) and older males (66.7 ± 1.2 years). In addition, we measured the voided volume (VV), maximum flow rate (Qmax), and average flow rate (Qave) using two UFMs (P-Flowdiary and PicoFlow2, without Freeflow) and compared the results with those using three UFMs (including Freeflow) from the previous study. We also compared VV and flow rate between young and older males. A comparison of the results between with and without Freeflow showed no significant differences in error rates for VV, Qmax and Qave. The error rate range for VV measured by an electronic balance versus that by the three UFMs was 1.2%-6.5%. A comparison of Qmax and Qave measured by the two medical UFMs with those measured by the scale-type UFM showed errors of 11.1%-13.2% and 21.4%-23.1%, respectively. These results indicate that the effects of Freeflow on VV, Qmax, and Qave are within the measurement errors. In other words, Freeflow does not affect the measurements of UFMs positioned downstream. The average VV, Qmax, and Qave were, respectively, 259.1 ± 190.8 mL, 27.0 ± 7.0 mL/s, and 15.0 ± 4.0 mL/s in young males; and 162.0 ± 72.7 mL, 18.1 ± 4.14 mL/s, and 9.5 ± 2.3 mL/s in older males. All the values were significantly higher in young males than in older males as determined by t-test.


  • Open Access

    Simultaneous Comparison of the Measurement Accuracy of a Developed Scale-type Uroflowmeter with That of Three Medical Uroflowmeters in Young Males

    by Yoji Ando, Tetsuya Fujita, Kazuki Nakajima

    Urine-related information, such as voided volume and flow rate, is important for the diagnosis of dysuria. Uroflowmeters, which are used for obtaining urine information, measure mainly the weight gain of the collection cup or the rotation of the impeller. These devices pose hygiene-related problems because of the contact between urine and the device. In addition, the patients are forced to urinate in unfamiliar environments and positions, which can lead to unusual results. Therefore, there is a need for a non-contact uroflowmeter that can measure urine information in an environment and a posture to which the user is accustomed. A uroflowmeter that measures the rise of the water level in the toilet bowl is also available; however, it requires extensive installation. To address these problems, we have developed a scale-type uroflowmeter that measures weight loss during standing urination. The purpose of this study was to evaluate the measurement accuracy of our developed scale-type uroflowmeter. For this purpose, human urination was measured simultaneously using the developed uroflowmeter and three different medical uroflowmeters (Freeflow®, P-Flowdiary®, and PicoFlow2®), to compare the voided volume, maximum flow rate, and average flow rate. The results of the developed uroflowmeter showed good agreement with the weight of urine measured by an electronic balance and the voided volume measured by the medical uroflowmeters. The error rates between the true voided volume measured by the electronic balance and the four uroflowmeters ranged from 0.9% to 22.5%. Comparing the maximum and average flow rates of the three medical uroflowmeters with the scale-type uroflowmeter, the error rates ranged from 9.4% to 25.4% and 17.4% to 25.2%, respectively.


  • Open Access

    Development of a Scale-type Uroflowmeter for Standing Urination

    by Ryuta Sakamoto, Tetsuya Fujita, Kazuki Nakajima

    A scale-type uroflowmeter designed specifically for male standing urination has been developed. While several uroflowmeters exist, most require the voided urine to come into contact with a uroflowmeter container or similar device. These devices and containers may become contaminated with urine, necessitating cleaning, and potentially serving as a breeding ground for infection. To address these issues, we developed a scale-type uroflowmeter. One example of a typical disease causing lower urinary tract symptoms is benign prostatic hyperplasia. Our uroflowmeter is designed to automatically measure the decrease in weight during standing urination. A basic study using water demonstrated an excellent correlation between the volume of water poured and the measured weight, with errors within 10 mL. Furthermore, a feasibility study involving five young and six older subjects showed good agreement in voided volume (VV) and maximum urinary flow rate (Qmax) between the novel device and a medical uroflowmeter. The average VV error rate was 5.30 ± 4.60%, and Qmax error rate was 15.74 ± 16.91%. The uroflowmeter for standing urination developed in this study allowed measurement of VV and Qmax with the same accuracy as the medical uroflowmeter. This system has the potential to be utilized as a noncontact uroflowmeter, offering a more hygienic and convenient solution for measuring urinary flow.


  • Open Access

    Redesigned Monitoring System for Television Usage and Light/Dark Room for Older People Living Alone

    by Kento Komatsu, Takatoshi Suenaga, Juhyon Kim, Kazuki Nakajima

    For older people who live alone, we previously designed a system that enabled family members at distant locations to monitor television (TV) usage and other activities of the older people, and the system has been used for over 10 years. This system comprises personal computers (PCs) that run on Microsoft Windows® operating system (OS) and a few sensors. The system forwards the TV usage data of the older person to family members through free e-mail. To operate the PCs safely for a longer period, regular updating of the OS and antivirus environment is necessary. Furthermore, the previous systems connected to the internet should be protected against cyberattacks to ensure information security and continuous system operation. To reduce the needs for system maintenance, we redesigned the existing monitoring system by incorporating sensors and microcomputers with an Arduino integrated development environment. A feasibility test was conducted for the new system, in which a 76-year-old woman and her family participated. Our findings showed that the new system was significantly maintenance-free, and the device size, when installed next to the TV, was approximately 90% smaller than the previous design. In addition, the new system performed as efficiently as the previous system.

  • Open Access

    A Basic Study on Capacitive Sensor for Diaper Absorption Volume Estimate

    by Keisuke Shichitani, Sota Tanaka, Yuki Fujio, Shintaro Yamamoto, Jyuhyon Kim, Kazuki Nakajima

    The production of disposable diapers is rising due to an increase in number of elderly people who require nursing care. When providing diaper care, it is difficult to know remotely the time of urination and amount of urine absorbed by a diaper. Hence, a remote sensor system that automatically records the time and amount of wine in a diaper is being developed. in this study, a digital capacitive sensor system was developed to estimate the amount of diaper absorption. Preliminary and phantom experiments were conducted to investigate the basic performance of the developed system. We also measured the amount of urination of two subjects using the developed system. A phantom, a waist-type torso mannequin filled with saline solution, and two male subjects wore pad-type diaper on the inside and tape-type diaper on the outside. Electrodes were attached to the outer surface of the tape-type diaper to measure the change in capacitance caused by urination. In the preliminary experiment, the developed system measured capacitors with known capacitance within 5.47% error. In the phantom experiment, the change in capacitance decreased as the amount of pseudo-wine absorbed by the pad-type diaper increased. Moreover, the results of human subjects urinating five times were consistent with the results of the preliminary experiment. Therefore, remote and quantitative evaluation of the urine absorption volume was possible using the developed digital system.


  • Open Access

    Ten Years' Tracking and Data of Television Usage of an Older Female Living Alone

    by Kazuki Nakajima

    Watching television (TV) is a popular leisure activity for older people and its usage is almost constant in the rhythm of their daily life. A telemonitoring system of television-operating-state for older people living alone has been developed, and an older female living alone has been using this system for 10 years. On her working days, the average TV usage was 192 min per day in the first year, increasing year by year to 329 min per day 10 years later. TV usage temporarily increased when some TV programs took up a social topic of interest to her.


  • Open Access

    Personal Identification Using a Ballistocardiogram During Urination Obtained from a Toilet Seat

    by Arata Nakagawa, Juhyon Kim, Kazuki Nakajima

    Many sensors have been developed to measure physiological information in the toilet for healthcare management and disease prevention. These sensors require personal identification to classify toilet users, assuming that several people use the same toilet. We aimed to provide biometrics based on cardiovascular physiological information obtained from a toilet seat. An electrocardiogram was measured by the toilet seat, and personal identification was performed, as in the previous study. In this study, we developed a ballistocardiographic (BCG) monitoring system using two vibration sensors installed beneath a toilet seat. We recorded 70 BCGs from seven healthy males during their urination. Peaks H, I, J, K, and L of the BCGs were clearly obtained. Twenty-six features such as amplitude and interval were calculated from the BCG peaks. Personal identification was performed using the Mahalanobis distance, and the accuracy of identification and equal error rate (EER) were calculated. The average identification accuracy was found to be 92.2%, and the average EER was found to be 34.1%. Although the EER was not sufficiently low, the average accuracy suggested that the proposed method using a toilet seat could provide adequate biometrics for application in the healthcare system.


  • Open Access

    Development of Capacitive Sensor for Diaper Absorption Volume

    by Shujiro Konno, Juhyon Kim, Kazuki Nakajima

    The number of people requiring care in Japan has increased with the increase in number of people aged 65 or more. Thus, the production of disposable diapers for the elderly is also increasing. Two types of diapers; pad-type and tape-type, are generally used in combination in nursing homes. Diaper change is a burden for both the caregiver and the care receiver. To reduce the number of diaper changes, this study aimed to develops electrodes as a capacitive sensor attached to the outer surface of the tape-type diaper. The capacitive sensor evaluates the absorption volume of the pad-type diaper, and consists of electrodes and a converter circuit that converts the capacitance of electrodes into an output voltage. The study used a waist-type torso mannequin wearing a pad-type diaper on the inside and a tape-type diaper on the outside. The inside of the torso was filled with saline, and the weight of the torso including the saline was 8.9 kg in total. The electrodes were made of copper tape fixed to an insulating film, and the copper tape was 500-mm long and 25-mm wide with a 20-mm interelectrode gap. The electrodes were attached to the outside of the tape-type diaper and connected to the circuit. Experiment was conducted with the torso placed in supine and 30º lateral positions. Tap water (100 mL) was introduced via a silicone tube between the pad-type diaper and the torso hip surface at a flow rate of 7.8 mL/s, which is the average urinary flow rate for the elderly. This procedure was repeated six times. The experiment was repeated three times. The output voltage increased linearly with increasing volume of water absorbed by the pad-type diaper, in both torso positions. Therefore, the absorption volume was quantitatively evaluated, and the results suggested that the resolution was at least 100 mL when using this sensor.