WMWalter Morale

Walter Morale

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Walter Morale has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Clinical use of computational modeling for surgical planning of arteriovenous fistula for hemodialysis

    by Michela Bozzetto, Stefano Rota, Valentina Vigo, Francesco Casucci, Carlo Lomonte, Walter Morale, Massimo Senatore, Luigi Tazza, Massimo Lodi, Giuseppe Remuzzi, et al.

    Autogenous arteriovenous fistula (AVF) is the best vascular access (VA) for hemodialysis, but its creation is still a critical procedure. Physical examination, vascular mapping and doppler ultrasound (DUS) evaluation are recommended for AVF planning, but they can not provide direct indication on AVF outcome. We recently developed and validated in a clinical trial a patient-specific computational model to predict pre-operatively the blood flow volume (BFV) in AVF for different surgical configuration on the basis of demographic, clinical and DUS data. In the present investigation we tested power of prediction and usability of the computational model in routine clinical setting. We developed a web-based system (AVF.SIM) that integrates the computational model in a single procedure, including data collection and transfer, simulation management and data storage. A usability test on observational data was designed to compare predicted vs. measured BFV and evaluate the acceptance of the system in the clinical setting. Six Italian nephrology units were involved in the evaluation for a 6-month period that included all incident dialysis patients with indication for AVF surgery. Out of the 74 patients, complete data from 60 patients were included in the final dataset. Predicted brachial BFV at 40 days after surgery showed a good correlation with measured values (in average 787 ± 306 vs. 751 ± 267 mL/min, R = 0.81, p < 0.001). For distal AVFs the mean difference (±SD) between predicted vs. measured BFV was −2.0 ± 20.9%, with 50% of predicted values in the range of 86–121% of measured BFV. Feedbacks provided by clinicians indicate that AVF.SIM is easy to use and well accepted in clinical routine, with limited additional workload. Clinical use of computational modeling for AVF surgical planning can help the surgeon to select the best surgical strategy, reducing AVF early failures and complications. This approach allows individualization of VA care, with the aim to reduce the costs associated with VA dysfunction, and to improve AVF clinical outcome.


  • Open Access

    Venae Comitantes as a Potential Vascular Resource to Create Native Arteriovenous Fistulae

    by Walter Morale, Domenico Patanè, Concetta Incardona, Giuseppe Seminara, Martina Messina, Pierantonio Malfa, Giuseppe L'ANfusa, Giuseppe D'ARrigo, Demetrio Spanti, Maria Luisa Mandalà, et al.

    Purpose: The arteriovenous fistula (AVF) represents the gold standard for hemodialysis (HD) vascular access. In some critical cases, use of the deep venous circle may represent an alternative approach and venae comitantes could be employed for this purpose. Methods: Sixty patients with chronic renal failure in which the deep venous circle was used to create an AVF were identified; of the 48 who had a direct anastomosis between the brachial artery and vena comitans, 42 had a long-term follow-up (mean follow-up 59 weeks), while six were lost to follow-up. Results: Immediate success (patency and palpable thrill) was achieved in 88% of cases (primary and early failure 12%). Primary accessibility rate was 62%, while 11 patients required a second surgical approach to make the vein accessible to needling. Secondary accessibility rate of 71% was due to surgical revisions. In the 80–week observation period, the complication rate was 10% with irreversible loss of the AVF in all these cases. Cumulative patency was 71% at the 80th week. Including all 42 patients, technical and functional success rate, defined as vein accessibility to needling and chance of an adequate HD treatment, was 62%. Conclusions: AVF employing venae comitantes may represent a suitable alternative in the absence of other vascular accesses for HD.


    • 22 April 2009
      • Vol. 26  (2) , 236-45

    [Steno-obstructions of haemodialytic FAV: new aspects of endovascular treatments].

    by D Patanè, W Morale, P Malfa, G Seminara, E Caudullo, G L'anfusa, D Spanti, C Incardona, M L Mandalà, L Infantone, et al.

    Angioplasty is the usual method for the treatment of stenosis of arteriovenous fistulas for hemodialysis, along with fibrinolysis and thrombus aspiration. We evaluated the efficacy and safety of interventional radiology procedures in the treatment of stenosis or occlusion of arteriovenous fistulas. One hundred thirteen patients suffering from malfunction of arteriovenous fistulas underwent interventional radiological procedures (140 treatments). In all patients color-Doppler was performed beforehand. Stenosis at the site of the fistula was found in all patients and was treated with percutaneous transluminal angioplasty (PTA); stenosis at the anastomosis site was found in 63 cases and was treated by angioplasty with a microcatheter. In 40 patients suffering from recent thrombotic occlusion, locoregional thrombolysis and PTA were necessary. Technical and clinical success was achieved in 107 patients (94.6%); in 1 of 6 unsuccessful treatments the procedure had to be interrupted due to the rupture of a vein. Follow-up exams demonstrated primary patency in 92.5%, 71.9% and 49.5% of patients at 6 months, 1 year and 2 years, respectively. In 19 patients (17.7%) hemodynamically significant restenosis was observed, which was treated with multiple PTAs (27 treatments, only 1 of which with a negative outcome), resulting in a 94.2% success rate; only 1 patient had to undergo a fourth PTA. The overall patency rate was 95%, 87.2%, 62.3% at 6 months, 1 year and 2 years, respectively. In our experience immediate success and excellent patency rates were observed, which persisted in the medium and long term. PTA, with thrombolysis and thromboaspiration, is the treatment of choice in cases of malfunctioning arteriovenous fistulas. PTA should always be attempted before making a new surgical access in order to preserve the vascular tree.


    • 3 December 2008
      • Vol. 25  (6) , 729-34

    [Use of venae comitantes in the creation of arteriovenous fistulas: retrospective evaluation of our experience].

    by W Morale, D Patane', G Seminara, C Incardona, P Malfa, G L'anfusa, E Caudullo, D Spanti, M L Mandala', D Di Landro

    In order to estimate the outcome of arteriovenous fistula (AVF) for hemodialysis, we reviewed our experience in the construction of AVFs using the venae comitantes in patients without an adequate superficial venous vascular territory. The study included 34 patients affected by end-stage renal disease in whom an AVF was created using the deep venous system. In 26 of them we performed an anastomosis between the brachial artery and its vena comitans. Immediate success, defined by the presence of a thrill at the end of the anastomosis, was obtained in 84%, while primary failure of the AVF (immediate postoperative failure) occurred in 3 patients (12%). Early failure, defined as failure within 6 weeks of AVF placement, occurred in 4% of patients. Of the 22 patients with a functioning AVF, 8 (36%) subsequently requested a second operation to bring the fistula to the surface. Some of these involved the placement of synthetic grafts for better accessibility. The primary patency of the AVFs was equal to 64%, while the patency after a second intervention was 91%. Among the 26 AVFs created with venae comitantes, total patency at 50 weeks was 62%. Our experience with the placement of prosthetic grafts draining into the venae comitantes has not provided encouraging results. We believe that for adequate exploitation of venae comitantes it is important to use native veins that have to meet specific anatomical and functional requirements. The creation of an AVF with a native vein, taking advantage of the deep venous system, is feasible under the right circumstances.

    • 30 July 2008
      • Vol. 25  (4) , 475-83

    [Central venous stenting in patients on hemodialysis: review of our case series and long-term follow-up].

    by D Patanè, W Morale, P Malfa, G Seminara, E Caudullo, G L'anfusa, D Spanti, M L Mandalà, D Di Landro

    Aims of the study was validate the venous stenting technique as the treatment of choice in patients affected by stenosis or occlusion of the central venous area. To evaluate the long-term patency of placed stents in our series and to detect factors predisposing to restenosis. Twenty-three hemodialyzed patients were treated by PTA or placement of a metallic self-expandable stent in the central venous area because of occlusion or severe stenosis caused by repeated central venous access puncture for Port-A-Cath or pacemaker placement. All patients were examined every 3 months after treatment by clinical examination and color-Doppler ultrasound. Stents were placed with success in all cases but one, where it was impossible to get past the occlusion. Restenosis was observed in 12 cases at 4 to 12 months (average 8 months). Intrastent restenoses were treated with success by PTA alone and stent placement in 4 cases. A new restenosis was observed in 4 retreated patients in whom the stent was short or angled. In the other patients restenosis was attributable to disregard of anticoagulant therapy. In conclusions, the availability of new devices and dedicated stents is still necessary. There is a limited relationship between patency and wrong stent placement. Patients undergoing stenting should be controlled by clinical examination and color-Doppler ultrasound in hospitals where skilled interventional radiologists are available.