KMKetij Mehulić

Ketij Mehulić

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ketij Mehulić has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Long-Term Chemical Solubility of 2.3Y-TZP Dental Ceramics

    by Lidija Ćurković, Sanja Štefančić, Irena Žmak, Vilko Mandić, Ivana Gabelica, Ketij Mehulić

    In this study, the chemical solubility (stability) of yttria-partially stabilized zirconia (2.3Y-TZP) dental ceramics, both glazed (Group 2) and non-glazed samples (Group 1), was evaluated using a modified testing protocol based on ISO 6872:2024. Chemical stability was assessed by measuring ion release with inductively coupled plasma mass spectrometry (ICP-MS) and by analyzing phase composition with X-ray diffraction (XRD). While ISO 6872 prescribes chemical stability testing in a 4 wt.% aqueous acetic acid solution at 80 °C for 16 h, the exposure duration in this study was extended to 768 h (32 days) to allow a more accurate determination of long-term solubility behavior. Additionally, the surface roughness parameters (Ra, Rmax, Rz, Sa, Sq) were analyzed and evaluated before and after solubility testing. Kinetic analysis revealed that degradation followed a near-parabolic rate law, with power-law exponents of n = 2.261 for Group 1 and n = 1.935 for Group 2. The corresponding dissolution rate constants were 3.85 × 10−5 µgn·cm−2n·h−1 for Group 1 and 132.3 µgn·cm−2n·h−1 for Group 2. XRD results indicated that the long exposure to acetic acid induced a partial phase transformation of zirconia from the tetragonal to the monoclinic phase. Under prolonged acetic exposure, the glaze layer on 2.3Y-TZP exhibited significantly higher dissolution, whereas the zirconia (polished, unglazed) showed low ion release. The temporal change in the total amount of dissolved ions was statistically analyzed for Group 1 and Group 2. The samples showed a strong correlation, but ANOVA confirmed significant differences between them.

  • Open Access

    Long-Term Corrosion Behavior of Y-TZP Dental Ceramics

    by Lidija Ćurković, Sanja Štefančić, Irena Žmak, Vilko Mandić, Ivana Gabelica, Ketij Mehulić

    Zirconia-based ceramics are widely used in dental applications due to their excellent mechanical and chemical properties. The aim of this study was to evaluate the chemi-cal stability of yttria partially stabilized zirconia (Y-TZP) dental ceramics using a modified testing protocol based on ISO 6872. Two sample groups of Y-TZP material were used: Group 1 - pure polished zirconia, and Group 2 - pure polished zirconia with an additional glaze layer. Chemical stability, defined as corrosion resistance, was as-sessed by measuring ion release using inductively coupled plasma mass spectrometry (ICP-MS) and by analysing the phase composition using X-ray diffraction (XRD). While ISO 6872 prescribes chemical stability testing in a 4 wt.% aqueous acetic acid (CH₃COOH) solution at 80 °C for 16 hours, the exposure duration in this study was extended to 768 hours (32 days) to enable more accurate determination of long-term corrosion behaviour. Kinetic analysis revealed that degradation followed a near-parabolic rate law, with power-law exponents of n = 2.261 for Group 1 and n = 1.935 for Group 2. The corresponding corrosion rate constants were 3.85 × 10−5 µgn⋅cm−2n⋅h−1 for Sample 1 and 132.3 µgn⋅cm−2n⋅h−1 for Sample 2. XRD results indicated that the corrosion process led to a partial phase transformation of zirconia from the tetragonal to the monoclinic phase.

  • Open Access

    Effect of Aging on the Microstructure and Optical Properties of Translucent ZrO 2 Ceramics

    by Korina Mešić, Igor Majnarić, Ketij Mehulić

    Objectives: The development and placement of translucent zirconia ceramics on the dental materials market is in full swing. This research aimed to investigate how aging protocols affect the microstructure, color parameters and translucency of a new-generation monolithic zirconia ceramic. Material and methods: Translucent zirconia ceramics KATANA-Zirconia STML with different surface treatments (as sintered - control, glazed, polished) was tested using two aging protocols (hydrothermal degradation in autoclave at 134 degrees C and 2 bars for three hours, chemical degradation in four-percent acetic acid at 80 degrees C for 16 hours) in order to examine phase composition using X-ray diffraction analysis and Delta E, Delta L and Delta C color parameters through spectrophotometry. The translucency parameter (TP) was calculated using parameters L*, a* and b* on a black and white surface. Results: Regardless of the surface treatment, aging protocols did not cause a tetragonal-to-monoclinic phase transformation, although hydrothermal degradation in the autoclave transformed the hybrid tetragonal-cubic structure of all specimens to a tetragonal one. All polished and glazed specimens during chemical degradation demonstrated a significant color change Delta E. Lightness Delta L significantly changed in polished specimens aged in the autoclave. In all specimens, Delta C underwent a change manifested through statistically insignificant yellowing. None of the aging protocols altered the translucency of specimens. Conclusions: Aging, regardless of the final surface treatment, did not manifest a monoclinic phase in the specimens. A tetragonal-cubic microstructure dominates. Unlike polishing, glazing the surface of translucent zirconia ceramics contributed to minor changes in color, lightness and chromaticity. The translucency of translucent zirconia ceramics remains stable regardless of aging and surface treatment.


  • Open Access

    The Effect of Aging on Composition and Surface of Translucent Zirconia Ceramic

    by Korina Mešić, Igor Majnarić, Jasmina Obhođaš, Gorana Baršić, Ketij Mehulić

    Objectives: To examine the effect of two aging protocols on the chemical and phase composition as well as the surface state of monolithic translucent zirconia ceramics. Material and Methods: Translucent zirconia ceramics KATANA-Zirconia STML with different surface treatments (no treatment, K1, K2; glazed, G1-G8; polished, P1-P8) underwent testing in order to examine how the two aging protocols (three-hour hydrothermal degradation in an autoclave at 134 °C and 2 bars: G1-G4, P1-P4, and sixteen-hour chemical degradation in four-percent acetic acid at 80 °C (ISO 6872): G5-G8, P5-P8) affect chemical composition, particularly the share of stabilizing yttrium oxide (Energy Dispersive XRay Fluorescence – EDXRF), phase composition (X-ray diffraction – XRD) and surface state in terms of roughness and gloss. Results: Aging protocols did not affect the tested chemical composition stability of specimens and a high share of stabilizing yttrium-oxide (≥10% of total content), which correlates with the absence of monoclinic phase. A decrease in gloss on all specimens is statistically significant. Chemical degradation substantially increased the surface roughness of tested specimens. Conclusions: Translucent monolithic zirconia demonstrated a stable chemical composition and resistance to tetragonal-to-monoclinic transformation. Surface gloss was significantly reduced, especially in polished specimens. Contrary to glazed specimens, the tested polished specimens manifested an increase in surface roughness. Glazing the surface of translucent monolithic zirconia produces better esthetic, tribological and hygienic effects than polishing.


  • Open Access

    Analysis of Translucency Parameter of Glass-Ceramics Fabricated by Different Techniques

    by Karla Ledić, Igor Majnarić, Slađana Milardović Ortolan, Stjepan Špalj, Sanja Štefančić, Ketij Mehulić

    Of the study was to analyse translucency parameter (TP values) of glass-ceramics fabricated by different techniques and investigate the effect of the corrosive medium on TP values. Three specimens of each type of IPS e.max ceramics (Ivoclar Vivadent, Schaan, Liechtenstein) were made in three colours (A2, C2 and B3) by three fabrication techniques (layering - e.max Ceram Dentin; heat-pressing - e.max Press; CAD/CAM - e.max CAD). Specimens were made in the form of plates (10 mm x 12 mm x 0.8 mm). CIE L*a*b* values were measured by a spectrophotometer (X-Rite DTP 20 Pulse, Neu Isenburg, Germany) before and after exposure to 4% acetic acid at 80 °C for 16 hours (ISO 6872) to calculate translucency parameter (TP values). Statistical data were analysed using the IBM SPSS 22 software. IPS e.max Ceram Dentin had significantly the lowest TP values, and IPS e.max Press the highest TP values of all colours (A2, C2, B3), both prior and after exposure to acid (p<0.001). The difference in TP values among colours was evident in the IPS e.max Ceram Dentin material, both before and after exposure to acid with a great effect size (p<0.001; η2 = 0.702 and 0.741), and in the IPS e.max Press material (p<0.001, effect size 0.547 and 0.576). CAD/CAD specimens showed uniform TP values between three colours. Further, exposure to a corrosive medium did not result in a statistically significant change of TP values in any of the materials tested. Different types of glass-ceramics showed significant difference in TP values both with respect to the fabrication technique and colour. Exposure to a corrosive medium did not result in a statistically significant change of TP values.


    • 1 March 2010
      • Vol. 34, 235-238

    A Study of the Surface Topography and Roughness of Glazed and Unglazed Feldspathic Ceramics

    by Ketij Mehulic, Vesna Svetlicic, Suzana Segota, Denis Vojvodic, Ivan Kovacic, Davor Katanec, Nikola Petricevic, Domagoj Glavina, Asja Celebic

    The aim of this study was to obtain the 3-D qualitative and quantitative nanoscale data of the surface topography and surface roughness of glazed and unglazed feldspathic ceramics. Twelve samples composed of Ni-Cr alloy (Wiron 99, Bego Germany) and feldspathic ceramics (IPS Classic, Ivoclar-Vivadent, Schaan, Liechtenstein) were prepared, and divided into two groups, dependent of the surface final finishing; 6 unglazed and 6 glazed samples. The surface of the samples was recorded and analysed by atomic force microscopy (ARM, Veeco Instruments, Santa Barbara, CA, USA). According to the results of this study, unglazed ceramic surface is significantly rougher than the glazed one, showing significantly higher root mean square (RMS), mean roughness (Ra) and maximum height (Z range values) (p<0.01), higher crystallites with sharper peaks and deeper pores. The roughness parameters of the unglazed samples were almost twice or even more higher than of the glazed samples. Exposed unglazed ceramic surfaces can therefore promote antagonistic tooth wear.


    • 1 September 2009
      • Vol. 33  (3) , 849-56

    Optoelectronic pantography diagnostics of temporomandibular disorders in patients with bruxism.

    by Ketij Mehulić, Renata Kevilj Gospić, Alenko Dundjer, Tomislav Skrinjarić, Sanja Stefancić, Denis Vojvodić, Margareta Perinić

    Temporomandibular disorders (TMD) is a joint term that encompasses a number of clinical symptoms that involve the teeth, masticatory musculature and temporomandibular joints (TMJ). They are a frequent cause of orofacial medical conditions. The aetiology of disorders is complex and individual etiologic factors are not sufficiently defined. Bruxism, in its centric or eccentric form, is becoming a frequent problem for dentists. The purpose of this study is to show factors of the condyle leading in patients with bruxism by optoelectronic pantography, and to establish the possibility of using optoelectronic pantography in the diagnostic procedure of TMD. Patients were selected (N = 42), with incomplete sets of teeth, without prosthodontic appliances and with traces and symptoms of TMD. After completing the history questionnaire a clinical check up and plaster cast analysis patients with bruxism were selected (N = 22) and without bruxism (N = 20). During the study optoelectronic String-condylocomp LR3, Dentron, D-Höchberg (software JAWS 30) was used. This study showed the possibility of applying optoelectronic pantography in TMD diagnostics and compares history, clinical and condylographic parameters in TMD patients with and without bruxism. Optoelectronic pantography enables us, by using relatively easy methods, to determine a more accurate diagnosis, highly important when choosing therapeutic methods and control of the aforementioned disorders.


    • 28 July 2009
      • Vol. 58, 367-73

    Metal-ceramic bond: how to improve?

    by K Mehulić, M Laus-Sosić

    Metal-ceramic restorations include the positive features of metal (strength, durability and stability) and ceramics (esthetics). The strong bond on the metal-ceramic interface is the basic prerequisite for the durability of the metal-ceramic restoration. The heating of metal construction results in the diffusion of certain atoms (tracers) on the surface. There they react with atmospheric oxygen creating in oxides which remain on the cast surface, because the reversible diffusion is prevented. Atoms of silica in ceramic are bound with these oxides as a result of which a metal-tracer-ceramic compound is formed and a chemical bond is realised. In addition to forming an oxide layer, the oxidation heat treatment (OHT) is applied for all alloys in order to remove the entrapped gas and eliminate surface contaminants. Surface metal preparation before porcelain application may also affect the bond strength of metal and ceramics. Roughened surface by sandblasting enables mechanical interlocking and an increased surface for bonding metal and ceramics. Applying a bonding agent may improve the quality of the bond of certain metal-ceramic restorations. Due to the continued oxidation of titanium and creation of a non-adherent oxide layer, the bond strength between titanium and ceramics is weak, which is attempted to be resolved by firing in an argon atmosphere.


    • 23 April 2008
      • Vol. 57, 47-51

    Failures in fabrication and treatment using ceramic crowns.

    by K Mehulić

    Dental ceramics is a constituent prosthodontic material with excellent aesthetic properties. It is stable, does not change shape, color or size, and is biotolerant. Treatment with ceramic restorations is a standard procedure in modern fixed prosthodontics. Because of its multiphase structure and the thermal processes it undergoes during the making of a fixed prosthodontic replacement, ceramics is highly sensitive to small failures in fabrication. These failures can develop into cracks that can ultimately cause fracture of restorations in use. This is why each phase of restoration in a dental practice and a dental laboratory requires professional skill. Selection of a definite ceramic system for a specific clinical case is more important than with other constituent materials. Patient selection, oral hygiene, masticatory force, as well as proper maintenance of instruments and devices for the fabrication of ceramic replacements are all important.

    • 4 October 2007
      • Vol. 56, 393-7

    Temporomandibular disorders and bruxism. Part I.

    by R Kevilj, K Mehulic, A Dundjer

    Correct functioning of the entire stomatognathic system is achieved by a compatible relationship of all its parts. Four determinants, by their mutual harmonious activity, dictate the function of the entire system: the teeth, periodontium with supporting structure, muscles, temporomandibular joint (TMJ) and CNS. In such a complex system a disorder of any integrative part causes disturbances also in other parts of the system. Changed functions can arise through organic disorder, and also iatrogenically by inadequate conservative, prosthetic, surgical or orthodontic therapy. For this reason it is often difficult to recognise the primary cause. The first responses of the system to the disorder are adaptive mechanisms which occur within one or more integrative parts, and depending on their intensity and duration symptoms grow more prominent. Tissue response can be ortho- or parafunctional. Attempts are made to exclude psychoemotional influences and the obstacle eliminated by either abrasion, clenching or grinding of the teeth. If the obstacle is not eliminated by abrasion, the cause of such functional disorder becomes the trigger for parafunctional activity. From a review of the relevant literature it can be concluded that parafunctional activity is caused by changed occlusion, with determined psychological habits of the patient and specific tissue response of the stomatognathic system. Therefore, therapy of these disorders is made more difficult and includes a multidisciplinary approach.