Lili He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lili He has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Avinish Kambadakone
Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
1 shared publicationBurkay Orten
Department of Electrical and Computer Engineering and Biomedical Engineering, Boston University, Boston, MA, USA
1 shared publicationDushyant V. Sahani
Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
1 shared publicationHomer Pien
Laboratory Medical Imaging and Computations, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
1 shared publicationIan R. Greenshields
Dept. of Comput. Sci. & Eng., Univ. of Connecticut, Storrs, CT
1 shared publicationSynho Do
Laboratory Medical Imaging and Computations, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
1 shared publication
Latest Publications
- 8 April 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 29 (5) , 1182-1191
A Spatio-Temporal Deconvolution Method to Improve Perfusion CT Quantification
Perfusion imaging is a useful adjunct to anatomic imaging in numerous diagnostic and therapy-monitoring settings. One approach to perfusion imaging is to assume a convolution relationship between a local arterial input function and the tissue enhancement profile of the region of interest via a ¿residue function¿ and subsequently solve for this residue function. This ill-posed problem is generally solved using singular-value decomposition based approaches, and the hemodynamic parameters are solved for each voxel independently. In this paper, we present a formulation which incorporates both spatial and temporal correlations, and show through simulations that this new formulation yields higher accuracy and greater robustness with respect to image noise. We also show using rectal cancer tumor images that this new formulation results in better segregation of normal and cancerous voxels.
- 8 April 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 29 (5) , 1182-1191
A Spatio-Temporal Deconvolution Method to Improve Perfusion CT Quantification
Perfusion imaging is a useful adjunct to anatomic imaging in numerous diagnostic and therapy-monitoring settings. One approach to perfusion imaging is to assume a convolution relationship between a local arterial input function and the tissue enhancement profile of the region of interest via a ¿residue function¿ and subsequently solve for this residue function. This ill-posed problem is generally solved using singular-value decomposition based approaches, and the hemodynamic parameters are solved for each voxel independently. In this paper, we present a formulation which incorporates both spatial and temporal correlations, and show through simulations that this new formulation yields higher accuracy and greater robustness with respect to image noise. We also show using rectal cancer tumor images that this new formulation results in better segregation of normal and cancerous voxels.
- 2 July 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 28 (2) , 165-172
A Nonlocal Maximum Likelihood Estimation Method for Rician Noise Reduction in MR Images
Postacquisition denoising of magnetic resonance (MR) images is of importance for clinical diagnosis and computerized analysis, such as tissue classification and segmentation. It has been shown that the noise in MR magnitude images follows a Rician distribution, which is signal-dependent when signal-to-noise ratio (SNR) is low. It is particularly difficult to remove the random fluctuations and bias introduced by Rician noise. The objective of this paper is to estimate the noise free signal from MR magnitude images. We model images as random fields and assume that pixels which have similar neighborhoods come from the same distribution. We propose a nonlocal maximum likelihood (NLML) estimation method for Rician noise reduction. Our method yields an optimal estimation result that is more accurate in recovering the true signal from Rician noise than NL means algorithm in the sense of SNR, contrast, and method error. We demonstrate that NLML performs better than the conventional local maximum likelihood (LML) estimation method in preserving and defining sharp tissue boundaries in terms of a well-defined sharpness metric while also having superior performance in method error.
- 2 July 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 28 (2) , 165-172
A Nonlocal Maximum Likelihood Estimation Method for Rician Noise Reduction in MR Images
Postacquisition denoising of magnetic resonance (MR) images is of importance for clinical diagnosis and computerized analysis, such as tissue classification and segmentation. It has been shown that the noise in MR magnitude images follows a Rician distribution, which is signal-dependent when signal-to-noise ratio (SNR) is low. It is particularly difficult to remove the random fluctuations and bias introduced by Rician noise. The objective of this paper is to estimate the noise free signal from MR magnitude images. We model images as random fields and assume that pixels which have similar neighborhoods come from the same distribution. We propose a nonlocal maximum likelihood (NLML) estimation method for Rician noise reduction. Our method yields an optimal estimation result that is more accurate in recovering the true signal from Rician noise than NL means algorithm in the sense of SNR, contrast, and method error. We demonstrate that NLML performs better than the conventional local maximum likelihood (LML) estimation method in preserving and defining sharp tissue boundaries in terms of a well-defined sharpness metric while also having superior performance in method error.