Wen-Yinn Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wen-Yinn Lin has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Chih-Chieh Chen
Institute of Environmental and Occupational Health Science, College of Public Health, National Taiwan University, Taipei 10055, Taiwan
4 shared publications Jin-Yuan Syu
Institute of Labor, Occupational Safety and Health, Ministry of Labor, New Taipei City, Taiwan
3 shared publicationsYuan-Yi Chang
Institute of Environmental Engineering and Management, National Taipei University of Technology, Taipei, 10608, Taiwan
3 shared publicationsChi-Ching Kuo
Institute of Organic and Polymeric Materials, National Taipei University of Technology, Taipei City, Taiwan
2 shared publicationsChih-Te Wang
Institute of Environmental Engineering and Management, National Taipei University of Technology, Taipei City, Taiwan
2 shared publications- Sheng-Hsiu Huang
Institute of Environmental and Occupational Health Science, College of Public Health, National Taiwan University, Taipei 10055, Taiwan
2 shared publications
Latest Publications
- 27 September 2019
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 53 (12) , 1441-1452
A novel-charged fibrous media characterized by higher efficiency and lower pressure drop
A new porous fiber shape was produced, one with a longitudinal notch. This new shape increases the surface area and therefore the overall number of pores, which in turn leads to a higher per-fiber surface charge density. Filters with charge generally show advantageous lower pressure drops when compared to the same filtration efficiencies. Although previous studies have hypothesized that increasing the surface area of porous fibers can improve charge capacity, but few experiments have proven this concept. In this study, two different micron-sized fibers were fabricated via electrospinning: smooth (“normal”) fibers and the novel notched fibers with surface pores. The fiber profile and voltage drop of the two fibers were measured, and the penetration rate of the two types of fibers before and after charging was measured with aerosol particles ranging from 25 nm to 478 nm in size. The results showed that the specific surface area of the notched fiber was 47.44 ± 0.67 m2 g−1, larger than that of the smooth fibers (2.64 ± 0.08 m2g−1). The notched fiber was charged by negative corona discharge, and the surface capacitance was measured to be -51.2 μC m−2 when the thickness was 0.19 mm, which was also larger than that of the smooth fibers (-38.2 μC m−2). When charged, the value of the average quality factor of the notched fibers increased from 0.030 Pa−1 to 0.068 Pa−1. Overall, the notched fibers demonstrated better filtration efficiency. We concluded that this novel fiber shape delivers both low penetration rates and low pressure drops. Copyright © 2019 American Association for Aerosol Research
- 27 September 2019
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 53 (12) , 1441-1452
A novel-charged fibrous media characterized by higher efficiency and lower pressure drop
A new porous fiber shape was produced, one with a longitudinal notch. This new shape increases the surface area and therefore the overall number of pores, which in turn leads to a higher per-fiber surface charge density. Filters with charge generally show advantageous lower pressure drops when compared to the same filtration efficiencies. Although previous studies have hypothesized that increasing the surface area of porous fibers can improve charge capacity, but few experiments have proven this concept. In this study, two different micron-sized fibers were fabricated via electrospinning: smooth (“normal”) fibers and the novel notched fibers with surface pores. The fiber profile and voltage drop of the two fibers were measured, and the penetration rate of the two types of fibers before and after charging was measured with aerosol particles ranging from 25 nm to 478 nm in size. The results showed that the specific surface area of the notched fiber was 47.44 ± 0.67 m2 g−1, larger than that of the smooth fibers (2.64 ± 0.08 m2g−1). The notched fiber was charged by negative corona discharge, and the surface capacitance was measured to be -51.2 μC m−2 when the thickness was 0.19 mm, which was also larger than that of the smooth fibers (-38.2 μC m−2). When charged, the value of the average quality factor of the notched fibers increased from 0.030 Pa−1 to 0.068 Pa−1. Overall, the notched fibers demonstrated better filtration efficiency. We concluded that this novel fiber shape delivers both low penetration rates and low pressure drops. Copyright © 2019 American Association for Aerosol Research
- 1 January 2018
- Published by Springer Nature in Aerosol and Air Quality Research
- Vol. 18 (6) , 1470-1482
Experimental Investigation of the Filtration Characteristics of Charged Porous Fibers
The international journal of Aerosol and Air Quality Research (AAQR) covers all aspects of aerosol science and technology, atmospheric science and air quality related issues.
- 1 January 2018
- Published by Springer Nature in Aerosol and Air Quality Research
- Vol. 18 (6) , 1470-1482
Experimental Investigation of the Filtration Characteristics of Charged Porous Fibers
The international journal of Aerosol and Air Quality Research (AAQR) covers all aspects of aerosol science and technology, atmospheric science and air quality related issues.
- Open Access
- 12 October 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (10) , e0186217
Filter quality of electret masks in filtering 14.6–594 nm aerosol particles: Effects of five decontamination methods
This study investigates the effects of five decontamination methods on the filter quality (qf) of three commercially available electret masks—N95, Gauze and Spunlace nonwoven masks. Newly developed evaluation methods, the overall filter quality (qf,o) and the qf ratio were applied to evaluate the effectiveness of decontamination methods for respirators. A scanning mobility particle sizer is utilized to measure the concentration of polydispersed particles with diameter 14.6–594 nm. The penetration of particles and pressure drop (Δp) through the mask are used to determine qf and qf,o. Experimental results reveal that the most penetrating particle size (MPS) for the pre-decontaminated N95, Gauze and Spunlace masks were 118 nm, 461 nm and 279 nm, respectively, and the respective penetration rates were 2.6%, 23.2% and 70.0%. The Δp through the pretreated N95 masks was 9.2 mm H2O at the breathing flow rate of heavy-duty workers, exceeding the Δp values obtained through Gauze and Spunlace masks. Decontamination increased the sizes of the most penetrating particles, changing the qf values of all of the masks: qf fell as particle size increased because the penetration increased. Bleach increased the Δp of N95, but destroyed the Gauze mask. However, the use of an autoclave reduces the Δp values of both the N95 and the Gauze mask. Neither the rice cooker nor ethanol altered the Δp of the Gauze mask. Chemical decontamination methods reduced the qf,o values for the three electret masks. The value of qf,o for PM0.1 exceeded that for PM0.1–0.6, because particles smaller than 100 nm had lower penetration, resulting in a better qf for a given pressure drop. The values of qf,o, particularly for PM0.1, reveal that for the tested treatments and masks, physical decontamination methods are less destructive to the filter than chemical methods. Nevertheless, when purchasing new or reusing FFRs, penetration should be regarded as the priority.
- 12 October 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (10) , e0186217
Open AccessFilter quality of electret masks in filtering 14.6–594 nm aerosol particles: Effects of five decontamination methods
This study investigates the effects of five decontamination methods on the filter quality (qf) of three commercially available electret masks—N95, Gauze and Spunlace nonwoven masks. Newly developed evaluation methods, the overall filter quality (qf,o) and the qf ratio were applied to evaluate the effectiveness of decontamination methods for respirators. A scanning mobility particle sizer is utilized to measure the concentration of polydispersed particles with diameter 14.6–594 nm. The penetration of particles and pressure drop (Δp) through the mask are used to determine qf and qf,o. Experimental results reveal that the most penetrating particle size (MPS) for the pre-decontaminated N95, Gauze and Spunlace masks were 118 nm, 461 nm and 279 nm, respectively, and the respective penetration rates were 2.6%, 23.2% and 70.0%. The Δp through the pretreated N95 masks was 9.2 mm H2O at the breathing flow rate of heavy-duty workers, exceeding the Δp values obtained through Gauze and Spunlace masks. Decontamination increased the sizes of the most penetrating particles, changing the qf values of all of the masks: qf fell as particle size increased because the penetration increased. Bleach increased the Δp of N95, but destroyed the Gauze mask. However, the use of an autoclave reduces the Δp values of both the N95 and the Gauze mask. Neither the rice cooker nor ethanol altered the Δp of the Gauze mask. Chemical decontamination methods reduced the qf,o values for the three electret masks. The value of qf,o for PM0.1 exceeded that for PM0.1–0.6, because particles smaller than 100 nm had lower penetration, resulting in a better qf for a given pressure drop. The values of qf,o, particularly for PM0.1, reveal that for the tested treatments and masks, physical decontamination methods are less destructive to the filter than chemical methods. Nevertheless, when purchasing new or reusing FFRs, penetration should be regarded as the priority.
- 1 January 2017
- Published by Springer Nature in Aerosol and Air Quality Research
- Vol. 17 (5) , 1256-1266
Measurement and Evaluation of Elastic Light Scattering from a Single Levitated Irregular Particle
The international journal of Aerosol and Air Quality Research (AAQR) covers all aspects of aerosol science and technology, atmospheric science and air quality related issues.
- 1 January 2017
- Published by Springer Nature in Aerosol and Air Quality Research
- Vol. 17 (5) , 1256-1266
Measurement and Evaluation of Elastic Light Scattering from a Single Levitated Irregular Particle
The international journal of Aerosol and Air Quality Research (AAQR) covers all aspects of aerosol science and technology, atmospheric science and air quality related issues.
- Open Access
- 1 January 2015
- Published by Springer Nature in Aerosol and Air Quality Research
- Vol. 15 (5) , 1823-1835
Characteristics of Aerosol Extinction Coefficient in Taipei Metropolitan Atmosphere
The international journal of Aerosol and Air Quality Research (AAQR) covers all aspects of aerosol science and technology, atmospheric science and air quality related issues.
- 1 January 2015
- Published by Springer Nature in Aerosol and Air Quality Research
- Vol. 15 (5) , 1823-1835
Open AccessCharacteristics of Aerosol Extinction Coefficient in Taipei Metropolitan Atmosphere
The international journal of Aerosol and Air Quality Research (AAQR) covers all aspects of aerosol science and technology, atmospheric science and air quality related issues.
- 7 March 2014
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 64 (8) , 970-978
Effects of water-emulsified fuel on a diesel engine generator’s thermal efficiency and exhaust
Water-emulsified diesel has proven itself as a technically sufficient improvement fuel to improve diesel engine fuel combustion emissions and engine performance. However, it has seldom been used in light-duty diesel engines. Therefore, this paper focuses on an investigation into the thermal efficiency and pollution emission analysis of a light-duty diesel engine generator fueled with different water content emulsified diesel fuels (WD, including WD-0, WD-5, WD-10, and WD-15). In this study, nitric oxide, carbon monoxide, hydrocarbons, and carbon dioxide were analyzed by a vehicle emission gas analyzer, and the particle size and number concentration were measured by an electrical low-pressure impactor. In addition, engine loading and fuel consumption were also measured to calculate the thermal efficiency. Measurement results suggested that water-emulsified diesel was useful to improve the thermal efficiency and the exhaust emission of a diesel engine. Obviously, the thermal efficiency was increased about 1.2 to 19.9%. In addition, water-emulsified diesel leads to a significant reduction of nitric oxide emission (less by about 18.3 to 45.4%). However, the particle number concentration emission might be increased if the loading of the generator becomes lower than or equal to 1800 W. In addition, exhaust particle size distributions were shifted toward larger particles at high loading. The consequence of this research proposed that the water-emulsified diesel was useful to improve the engine performance and some of exhaust emissions, especially the NO emission reduction.
- 7 March 2014
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 64 (8) , 970-978
Effects of water-emulsified fuel on a diesel engine generator’s thermal efficiency and exhaust
Water-emulsified diesel has proven itself as a technically sufficient improvement fuel to improve diesel engine fuel combustion emissions and engine performance. However, it has seldom been used in light-duty diesel engines. Therefore, this paper focuses on an investigation into the thermal efficiency and pollution emission analysis of a light-duty diesel engine generator fueled with different water content emulsified diesel fuels (WD, including WD-0, WD-5, WD-10, and WD-15). In this study, nitric oxide, carbon monoxide, hydrocarbons, and carbon dioxide were analyzed by a vehicle emission gas analyzer, and the particle size and number concentration were measured by an electrical low-pressure impactor. In addition, engine loading and fuel consumption were also measured to calculate the thermal efficiency. Measurement results suggested that water-emulsified diesel was useful to improve the thermal efficiency and the exhaust emission of a diesel engine. Obviously, the thermal efficiency was increased about 1.2 to 19.9%. In addition, water-emulsified diesel leads to a significant reduction of nitric oxide emission (less by about 18.3 to 45.4%). However, the particle number concentration emission might be increased if the loading of the generator becomes lower than or equal to 1800 W. In addition, exhaust particle size distributions were shifted toward larger particles at high loading. The consequence of this research proposed that the water-emulsified diesel was useful to improve the engine performance and some of exhaust emissions, especially the NO emission reduction.
- 1 February 2010
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 60 (2) , 142-148
Effect of Ethanol-Gasoline Blends on Small Engine Generator Energy Efficiency and Exhaust Emission
This study was focused on fuel energy efficiency and pollution analysis of different ratios of ethanol-gasoline blended fuels (E0, E3, E6, and E9) under different loadings. In this research, the ex...
- 1 February 2010
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 60 (2) , 142-148
Effect of Ethanol-Gasoline Blends on Small Engine Generator Energy Efficiency and Exhaust Emission
This study was focused on fuel energy efficiency and pollution analysis of different ratios of ethanol-gasoline blended fuels (E0, E3, E6, and E9) under different loadings. In this research, the ex...