Hye Min Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hye Min Park has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Chan-Jong Park
1 shared publicationDong-Sung Kim
1 shared publicationJeong-Ho Kim
1 shared publicationJoong-Suk Youn
1 shared publicationKi-Hyun Park
1 shared publication- Koan Sik Joo
University of Myongji
1 shared publication
Latest Publications
- Open Access
Development and Performance Characteristics of Personal Gamma Spectrometer for Radiation Monitoring Applications
In this study, a personal gamma (γ) spectrometer was developed for use in applications in various fields, such as homeland security and environmental radiation monitoring systems. The prototype consisted of a 3 × 3 × 20 mm3 Ce-doped Gd–Al–Ga–garnet (Ce:GAGG) crystal that was coupled to a Si photomultiplier (SiPM) to measure γ radiation. The γ spectrometer could be accessed remotely via a mobile device. At room temperature, the implemented Ce:GAGG-SiPM spectrometer achieved energy resolutions of 13.5%, 6.9%, 5.8%, and 2.3% for 133Ba at 0.356 MeV, 22Na at 0.511 MeV, 137Cs at 0.662 MeV, and 60Co at 1.33 MeV, respectively. It consumed only about 2.7 W of power, had a mass of just 340 g (including the battery), and measured only 5.0 × 7.0 cm2.
Open AccessDevelopment and Performance Characteristics of Personal Gamma Spectrometer for Radiation Monitoring Applications
In this study, a personal gamma (γ) spectrometer was developed for use in applications in various fields, such as homeland security and environmental radiation monitoring systems. The prototype consisted of a 3 × 3 × 20 mm3 Ce-doped Gd–Al–Ga–garnet (Ce:GAGG) crystal that was coupled to a Si photomultiplier (SiPM) to measure γ radiation. The γ spectrometer could be accessed remotely via a mobile device. At room temperature, the implemented Ce:GAGG-SiPM spectrometer achieved energy resolutions of 13.5%, 6.9%, 5.8%, and 2.3% for 133Ba at 0.356 MeV, 22Na at 0.511 MeV, 137Cs at 0.662 MeV, and 60Co at 1.33 MeV, respectively. It consumed only about 2.7 W of power, had a mass of just 340 g (including the battery), and measured only 5.0 × 7.0 cm2.
- Open Access
- 28 April 2016
- Published by David Publishing Company in Journal of Physical Science and Application
- Vol. 6 (4)
X-ray Spectra Calculations for Inspection of Semiconductors with Different Target/Filter Combinations Using MCNPX
- 28 April 2016
- Published by David Publishing Company in Journal of Physical Science and Application
- Vol. 6 (4)
Open AccessX-ray Spectra Calculations for Inspection of Semiconductors with Different Target/Filter Combinations Using MCNPX