KPKirti P. Patel

Kirti P. Patel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kirti P. Patel has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Ara A. Vaporciyan

    Department of Thoracic and Cardiovascular Surgery, McGovern Medical School, Houston, Texas

    1 shared publication
  • Bindu Akkanti

    Divisions of Critical Care Medicine and Pulmonary and Sleep Medicine, Department of Internal Medicine, McGovern Medical School, Houston, Texas

    1 shared publication
  • Biswajit Kar

    Center for Advanced Heart Failure, McGovern Medical School and Memorial Hermann Hospital-Texas Medical Center, Houston, Texas

    1 shared publication
  • David W. Holt

    †Graduate Degree Completion Program, Clinical Perfusion Education, School of Allied Health Professions, University of Nebraska Medical Center, Omaha, Nebraska

    1 shared publication
  • Emmanuel Nunez-Centanu

    Center for Advanced Heart Failure, McGovern Medical School and Memorial Hermann Hospital-Texas Medical Center, Houston, Texas

    1 shared publication
  • Farshad Raissi Shabari

    Center for Advanced Heart Failure, McGovern Medical School and Memorial Hermann Hospital-Texas Medical Center, Houston, Texas

    1 shared publication

Latest Publications

  • Open Access

    Low-Flow Extracorporeal Carbon Dioxide Removal Using the Hemolung Respiratory Dialysis System® to Facilitate Lung-Protective Mechanical Ventilation in Acute Respiratory Distress Syndrome

    by Bindu Akkanti, Keshava Rajagopal, Kirti P. Patel, Sangeeta Aravind, Emmanuel Nunez-Centanu, Rahat Hussain, Farshad Raissi Shabari, Wayne L. Hofstetter, Ara A. Vaporciyan, Igor S. Banjac, et al.

    Extracorporeal carbon dioxide removal (ECCO2R) permits reductions in alveolar ventilation requirements that the lungs would otherwise have to provide. This concept was applied to a case of hypercapnia refractory to high-level invasive mechanical ventilator support. We present a case of an 18-year-old man who developed post-pneumonectomy acute respiratory distress syndrome (ARDS) after resection of a mediastinal germ cell tumor involving the left lung hilum. Hypercapnia and hypoxemia persisted despite ventilator support even at traumatic levels. ECCO2R using a miniaturized system was instituted and provided effective carbon dioxide elimination. This facilitated establishment of lung-protective ventilator settings and lung function recovery. Extracorporeal lung support increasingly is being applied to treat ARDS. However, conventional extracorporeal membrane oxygenation (ECMO) generally involves using large cannulae capable of carrying high flow rates. A subset of patients with ARDS has mixed hypercapnia and hypoxemia despite high-level ventilator support. In the absence of profound hypoxemia, ECCO2R may be used to reduce ventilator support requirements to lung-protective levels, while avoiding risks associated with conventional ECMO.


  • Open Access

    Off-Pump Coronary Artery Bypass Grafting for Spontaneous Coronary Dissection in a 26-Year-Old Patient Two Weeks Post-Partum: A Case Report and Review

    by Kirti P. Patel, Rodolfo P. Sotolongo, Terry W. Myrick

    Spontaneous coronary artery dissections are an infrequent cause of myocardial infarction and have been reported in late stages of pregnancy and in the puerperium phase. We report a case of a 26-year-old post-partum woman who was diagnosed with a spiral coronary dissection of the left anterior descending artery, with a compromised diagonal branch. She underwent an emergent surgical revascularization without the use of cardiopulmonary bypass. The patient’s in-hospital clinical course, prognosis, treatment, and potential etiologies are discussed.


  • Open Access

    Hemoglobin Test Result Variability and Cost Analysis of Eight Different Analyzers During Open Heart Surgery

    by Kirti P. Patel, Gary W. Hay, Mahesh Keitheri Cheteri, David W. Holt

    The purpose of this study was to compare the variation in hemoglobin (Hgb) values among various point-of-care (POC) analyzers available on the market. Eight analyzers (Gem 3000, ABL 720, ABL 77, Rapidpoint 405, IL 682, GemOPL, Hb 201+, and manual/centrifugation) were compared with the Hgb values from the Beckman Coulter LH750. A total of 72 patient samples were analyzed on each test instrument. The samples were obtained after intubation, after heparinization, during cardiopulmonary bypass, and after protamine administration. Four of the samples were excluded from the study because of delayed sample analysis. The calculated mean differences of reference test method Hgb (mean ± SD) for all samples (n = 68) were Gem 3000 = 1.431 ± 0.396 g/dL; ABL 720 = −0.224 ± 0.240 g/dL; ABL 77 = 0.341 ± 0.578 g/dL; Rapidpoint 405 = 0.001 ± 0.205 g/dL; IL 682 = −0.137 ± 0.232 g/dL; GemOPL = 0.774 ± 0.427 g/dL; Hb 201+ = 0.110 ± 0.524 g/dL; and manual/centrifugation = 0.547 ± 0.499 g/dL. Cumulative results indicated that the bias in Hgb values from the Gem 3000, ABL720, ABL 77, IL 682, GemOPL, and the manual method were statistically significant (p < .05), compared with the Coulter LH750. Additionally, only the Rapidpoint 405 and Hb 201+ most closely matched the values from the Coulter LH750 (p > .05). Some of the methodologies have previously been shown to be affected during hemodilution, hypoproteinemia, and/or after blood transfusion. There is variability among methodologies, which can give rise to statistically different Hgb values, and one should consider the “ideal” instrument based on this and many other factors. Based on our results, the rank order of closest approximation to the Coulter LH750 measurement was Rapidpoint 405, Hb 201+, IL 682, ABL 720, ABL 77, manual/centrifugation, GemOPL, and Gem 3000.