Weijun Yao
Research Subjects
Weijun Yao has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Juan Bascunan
FBML/MIT, Cambridge, MA, USA
3 shared publicationsSeungyong Hahn
FBML/MIT, Cambridge, MA, USA
3 shared publicationsYukikazu Iwasa
FBML/MIT, Cambridge, MA, USA
3 shared publications- Haigun Lee
Department of Materials Science and Engineering, Korea University, Seoul, Korea
1 shared publication - Juan Bascunan
Francis Bitter Magnet Laboratory (FBML)Plasma Science and Fusion Center (PSFC), Massachusetts Institute of Technology (MIT), Cambridge, MA, USA
1 shared publication - Min Cheol Ahn
MIT, Francis Bitter Magnet Lab, Cambridge, MA 02139 USA
1 shared publication
Latest Publications
- 19 April 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 20 (3) , 756-759
${\rm MgB}_{2}$ Coils for MRI Applications
In this paper, we report our progress in the development of a low cost, liquid-helium-free MgB 2 superconducting MRI magnet. Several technical issues related to the construction of such a magnet to operate in persistent current mode are discussed, namely, the performance consistency of long length MgB 2 conductors, the fabrication of superconducting joints and persistent current switches. Quench detection and protection of such magnets operated in solid nitrogen environment are also discussed.
- 19 April 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 20 (3) , 756-759
${\rm MgB}_{2}$ Coils for MRI Applications
In this paper, we report our progress in the development of a low cost, liquid-helium-free MgB 2 superconducting MRI magnet. Several technical issues related to the construction of such a magnet to operate in persistent current mode are discussed, namely, the performance consistency of long length MgB 2 conductors, the fabrication of superconducting joints and persistent current switches. Quench detection and protection of such magnets operated in solid nitrogen environment are also discussed.
- 30 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 19 (3) , 2285-2288
Nonlinear Behavior of a Shim Coil in an LTS/HTS NMR Magnet With an HTS Insert Comprising Double-Pancake HTS-Tape Coils
This paper reports results, experimental and analytical, of the nonlinear behavior of a shim coil in the presence of an HTS coil assembled with double-pancake (DP) HTS-tape coils. The experimental results are from: 1) operation of a 700 MHz LTS/HTS NMR magnet (LH700) consisting of a 600 MHz LTS NMR magnet (L600) equipped with superconducting shim coils and a 100 MHz DP-assembled HTS insert (H100) and; 2) an experiment with a room-temperature (RT) Z1 shim coil coupled to a 50 MHz DP-assembled HTS insert (H50). A field mapping theory with a harmonic analysis is applied to interpret both results. Based on experimental results and analyses, we conclude that the screening-current-induced field (SCF) generated by a DP-assembled HTS insert is primarily responsible for the nonlinear behavior, including strength degradation, of a shim coil.
- 30 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 19 (3) , 2285-2288
Nonlinear Behavior of a Shim Coil in an LTS/HTS NMR Magnet With an HTS Insert Comprising Double-Pancake HTS-Tape Coils
This paper reports results, experimental and analytical, of the nonlinear behavior of a shim coil in the presence of an HTS coil assembled with double-pancake (DP) HTS-tape coils. The experimental results are from: 1) operation of a 700 MHz LTS/HTS NMR magnet (LH700) consisting of a 600 MHz LTS NMR magnet (L600) equipped with superconducting shim coils and a 100 MHz DP-assembled HTS insert (H100) and; 2) an experiment with a room-temperature (RT) Z1 shim coil coupled to a 50 MHz DP-assembled HTS insert (H50). A field mapping theory with a harmonic analysis is applied to interpret both results. Based on experimental results and analyses, we conclude that the screening-current-induced field (SCF) generated by a DP-assembled HTS insert is primarily responsible for the nonlinear behavior, including strength degradation, of a shim coil.
- 5 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 19 (3) , 2261-2264
A Superconducting Joint Technique for ${\rm MgB}_{2}$ Round WiresThis paper describes a technique to superconductively splice multifilament MgB 2 wires. To date the technique has achieved joints capable of carrying a superconducting current of 200 A at 10 K in self field. Joints details, as well as testing methods and results are presented here.
- 5 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 19 (3) , 2261-2264
A Superconducting Joint Technique for ${\rm MgB}_{2}$ Round WiresThis paper describes a technique to superconductively splice multifilament MgB 2 wires. To date the technique has achieved joints capable of carrying a superconducting current of 200 A at 10 K in self field. Joints details, as well as testing methods and results are presented here.
- 30 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 18 (2) , 912-915
A Solid Nitrogen Cooled ${\hbox{MgB}}_{2}$ “Demonstration” Coil for MRI ApplicationsA 700-mm bore superconducting magnet was built and operated in our laboratory to demonstrate the feasibility of newly developed superconductor wire for fabricating MRI magnets. The magnet, an assembly of 10 coils each wound with a reacted and s-glass insulated wire 1-km long, was immersed in solid nitrogen rather than in a bath of liquid cryogen. This magnet was designed to operate in the temperature range 10-15 K, maintained by a cryocooler. A combination of this ldquowiderdquo temperature range and immersion of the winding in solid nitrogen enables this magnet to operate under conditions not possible with a low temperature superconductor (LTS) counterpart. Tested individually at 13 K, each coil could carry current up to 100 A. When assembled into the magnet, some coils, however, became resistive, causing the magnet to prematurely quench at currents ranging from 79 A to 88 A, at which point the magnet generated a center field of 0.54 T. Despite the presence of a large volume (50 liters) of solid nitrogen in the cold body, cooldown from 77 K to 10 K went smoothly.
- 30 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 18 (2) , 912-915
A Solid Nitrogen Cooled ${\hbox{MgB}}_{2}$ “Demonstration” Coil for MRI ApplicationsA 700-mm bore superconducting magnet was built and operated in our laboratory to demonstrate the feasibility of newly developed superconductor wire for fabricating MRI magnets. The magnet, an assembly of 10 coils each wound with a reacted and s-glass insulated wire 1-km long, was immersed in solid nitrogen rather than in a bath of liquid cryogen. This magnet was designed to operate in the temperature range 10-15 K, maintained by a cryocooler. A combination of this ldquowiderdquo temperature range and immersion of the winding in solid nitrogen enables this magnet to operate under conditions not possible with a low temperature superconductor (LTS) counterpart. Tested individually at 13 K, each coil could carry current up to 100 A. When assembled into the magnet, some coils, however, became resistive, causing the magnet to prematurely quench at currents ranging from 79 A to 88 A, at which point the magnet generated a center field of 0.54 T. Despite the presence of a large volume (50 liters) of solid nitrogen in the cold body, cooldown from 77 K to 10 K went smoothly.