Y. Losier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Y. Losier has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Bernie Hudgins
Senior Member, IEEE, Director, Institute of Biomedical Engineering, University of New Brunswick, Fredericton, NB, Canada
2 shared publications - Kevin Englehart
Institute of Biomedical Engineering, University of New Brunswick, Fredericton, Canada
2 shared publications - Blair A. Lock
Center of Bionic Medicine, Rehabilitation Institute of Chicago, Chicago, IL, USA
1 shared publication - L. Hargrove
Institute of Biomedical Engineering, University of New Brunswick, Fredericton, NB Canada
1 shared publication
Latest Publications
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 4842-4845
A Real-Time Pattern Recognition Based Myoelectric Control Usability Study Implemented in a Virtual Environment
Pattern recognition based myoelectric control systems have been well researched; however very few systems have been implemented in a clinical environment. Although classification accuracy or classification error is the metric most often reported to describe how well these control systems perform, very little work research has been conducted to relate this measure to the usability of the system. This work presents a virtual clothespin usability test to assess the performance of pattern recognition based myoelectric control systems. The results suggest that users can complete the virtual task in reasonable time frames when using systems with high classification accuracies. Additionally, results indicate that a clinically-supported classifier training approach (inclusion of the transient potion of contraction signals) may reduce classification accuracy but increase real-time performance.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 4842-4845
A Real-Time Pattern Recognition Based Myoelectric Control Usability Study Implemented in a Virtual Environment
Pattern recognition based myoelectric control systems have been well researched; however very few systems have been implemented in a clinical environment. Although classification accuracy or classification error is the metric most often reported to describe how well these control systems perform, very little work research has been conducted to relate this measure to the usability of the system. This work presents a virtual clothespin usability test to assess the performance of pattern recognition based myoelectric control systems. The results suggest that users can complete the virtual task in reasonable time frames when using systems with high classification accuracies. Additionally, results indicate that a clinically-supported classifier training approach (inclusion of the transient potion of contraction signals) may reduce classification accuracy but increase real-time performance.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 6137-6140
A Control System for a Powered Prosthesis Using Positional and Myoelectric Inputs from the Shoulder Complex
The integration of multiple input sources within a control strategy for powered upper limb prostheses could provide smoother, more intuitive multi-joint reaching movements based on the users intended motion. The work presented in this paper presents the results of using myoelectric signals (MES) of the shoulder area in combination with the position of the shoulder as input sources to multiple linear discriminant analysis classifiers. Such an approach may provide users with control signals capable of controlling three degrees of freedom (DOF). This work is another important step in the development of hybrid systems that will enable simultaneous control of multiple degrees of freedom used for reaching tasks in a prosthetic limb.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 6137-6140
A Control System for a Powered Prosthesis Using Positional and Myoelectric Inputs from the Shoulder Complex
The integration of multiple input sources within a control strategy for powered upper limb prostheses could provide smoother, more intuitive multi-joint reaching movements based on the users intended motion. The work presented in this paper presents the results of using myoelectric signals (MES) of the shoulder area in combination with the position of the shoulder as input sources to multiple linear discriminant analysis classifiers. Such an approach may provide users with control signals capable of controlling three degrees of freedom (DOF). This work is another important step in the development of hybrid systems that will enable simultaneous control of multiple degrees of freedom used for reaching tasks in a prosthetic limb.