J. Jossinet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
J. Jossinet has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Eric McAdams
Senior Member, IEEE, Northem Ireland BioEngineering Centre, University of Ulster, BT37 0QB N. Ireland UK. phone: +44 (0)28 9036 8127; fax: +44(0)28 9036 8068
2 shared publications - R. Subramanian
NIBEC, University of Ulster, Jordanstown, Northern Ireland, UK
2 shared publications - R.G.E. McCauley
University of Ulster, Jordanstown, Northern Ireland, UK
2 shared publications C Trillaud
1 shared publicationE. McAdams
1 shared publication- E. T. McAdams
NIBEC, University of Ulster at Jordanstown, N. Ireland
1 shared publication
Latest Publications
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 4594-4597
Characterization of gold electrodes in phosphate buffered saline solution by impedance and noise measurements for biological applications
Impedance spectroscopy and noise measurements have been used to study gold electrodes of three different surface areas in phosphate buffered saline (PBS) solution. The gold-PBS solution interface can be modeled by a charge transfer resistance in parallel with an interfacial constant phase element (CPE) which are in series with the solution resistance. The voltage noise fluctuations were analyzed using the fast Fourier transform (FFT) method. It is found that the voltage noise power is characterized by a 1/falpha spectrum in the low frequency range. The value of alpha is observed to be double that of the CPE coefficient beta. The authors suggest a link between the interface impedance and the measured noise
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 4594-4597
Characterization of gold electrodes in phosphate buffered saline solution by impedance and noise measurements for biological applications
Impedance spectroscopy and noise measurements have been used to study gold electrodes of three different surface areas in phosphate buffered saline (PBS) solution. The gold-PBS solution interface can be modeled by a charge transfer resistance in parallel with an interfacial constant phase element (CPE) which are in series with the solution resistance. The voltage noise fluctuations were analyzed using the fast Fourier transform (FFT) method. It is found that the voltage noise power is characterized by a 1/falpha spectrum in the low frequency range. The value of alpha is observed to be double that of the CPE coefficient beta. The authors suggest a link between the interface impedance and the measured noise
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 4594-4597
Characterization of gold electrodes in phosphate buffered saline solution by impedance and noise measurements for biological applications
Impedance spectroscopy and noise measurements have been used to study gold electrodes of three different surface areas in phosphate buffered saline (PBS) solution. The gold-PBS solution interface can be modeled by a charge transfer resistance in parallel with an interfacial constant phase element (CPE) which are in series with the solution resistance. The voltage noise fluctuations were analyzed using the fast Fourier transform (FFT) method. It is found that the voltage noise power is characterized by a 1/falpha spectrum in the low frequency range. The value of alpha is observed to be double that of the CPE coefficient beta. The authors suggest a link between the interface impedance and the measured noise
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 4594-4597
Characterization of gold electrodes in phosphate buffered saline solution by impedance and noise measurements for biological applications
Impedance spectroscopy and noise measurements have been used to study gold electrodes of three different surface areas in phosphate buffered saline (PBS) solution. The gold-PBS solution interface can be modeled by a charge transfer resistance in parallel with an interfacial constant phase element (CPE) which are in series with the solution resistance. The voltage noise fluctuations were analyzed using the fast Fourier transform (FFT) method. It is found that the voltage noise power is characterized by a 1/falpha spectrum in the low frequency range. The value of alpha is observed to be double that of the CPE coefficient beta. The authors suggest a link between the interface impedance and the measured noise
- 24 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1490-1491
Hydrogel Electrodes In Biosignal Recording
- 24 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1490-1491
Hydrogel Electrodes In Biosignal Recording
- 1 January 1993
- Vol. 19 (4) , 167-72
A high frequency electrical impedance tomograph using distributed parallel input channels.
Electrical Impedance Tomography (EIT) is an imaging technique based on multiple impedance measurements using electronically multiplexed surface electrodes. The present study describes an EIT prototype tomograph which uses two frequencies of applied signal: 31.25 kHz (within the frequency range originally used in early EIT studies) and 250 kHz. The use of the latter frequency was made possible as a result of several technical innovations including the use of separate groups of electrodes for current injection and for differential voltage measurement and the use of parallel input channels distributed around the object. In vitro images were successfully obtained using the system at the above two frequencies. It is concluded from this study that Electrical Impedance Tomography can be used at sufficiently high frequencies to enable bio-electrical tissue characterisation.
- 1 January 1993
- Vol. 19 (4) , 167-72
A high frequency electrical impedance tomograph using distributed parallel input channels.
Electrical Impedance Tomography (EIT) is an imaging technique based on multiple impedance measurements using electronically multiplexed surface electrodes. The present study describes an EIT prototype tomograph which uses two frequencies of applied signal: 31.25 kHz (within the frequency range originally used in early EIT studies) and 250 kHz. The use of the latter frequency was made possible as a result of several technical innovations including the use of separate groups of electrodes for current injection and for differential voltage measurement and the use of parallel input channels distributed around the object. In vitro images were successfully obtained using the system at the above two frequencies. It is concluded from this study that Electrical Impedance Tomography can be used at sufficiently high frequencies to enable bio-electrical tissue characterisation.