MNMohammad S. Nambakhsh

Mohammad S. Nambakhsh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohammad S. Nambakhsh has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Morphological Heart Arrhythmia Detection Using Hermitian Basis Functions and kNN Classifier

    by S. Karimifard, A. Ahmadian, M. Khoshnevisan, M. S. Nambakhsh

    This paper presents the results of morphological heart arrhythmia detection based on features of electrocardiography, ECG, signal. These signals are obtained from MIT/BIH arrhythmia database. The ECG beats were first modeled using Hermitian basis functions, (HBF). In this step, the width parameter, sigma, of HBF was optimized to minimize the model error. Then, the feature vector which consists of the parameters of the model is used as an input to k-nearest neighbor, kNN, classifier to examine the efficiency of the model. In our experiments, seven different types of arrhythmias have been considered. We achieved the sensitivity of 99.00% and specificity of 99.84% which are comparable to previous works. These results were obtained in less than 0.6 second which is suitable for real-time diagnosis of heart arrhythmias


  • A Novel Blind Watermarking of ECG Signals on Medical Images Using EZW Algorithm

    by Mohammad S. Nambakhsh, Alireza Ahmadian, Mohammad Ghavami, Reza S. Dilmaghani, S. Karimi-Fard

    In this paper, we present a novel blind watermarking method with secret key by embedding ECG signals in medical images. The embedding is done when the original image is compressed using the embedded zero-tree wavelet (EZW) algorithm. The extraction process is performed at the decompression time of the watermarked image. Our algorithm has been tested on several CT and MRI images and the peak signal to noise ratio (PSNR) between the original and watermarked image is greater than 35 dB for watermarking of 512 to 8192 bytes of the mark signal. The proposed method is able to utilize about 15% of the host image to embed the mark signal. This marking percentage has improved previous works while preserving the image details


  • A Novel Blind Watermarking of ECG Signals on Medical Images Using EZW Algorithm

    by Mohammad S. Nambakhsh, Alireza Ahmadian, Mohammad Ghavami, Reza S. Dilmaghani, S. Karimi-Fard

    In this paper, we present a novel blind watermarking method with secret key by embedding ECG signals in medical images. The embedding is done when the original image is compressed using the embedded zero-tree wavelet (EZW) algorithm. The extraction process is performed at the decompression time of the watermarked image. Our algorithm has been tested on several CT and MRI images and the peak signal to noise ratio (PSNR) between the original and watermarked image is greater than 35 dB for watermarking of 512 to 8192 bytes of the mark signal. The proposed method is able to utilize about 15% of the host image to embed the mark signal. This marking percentage has improved previous works while preserving the image details

  • Morphological Heart Arrhythmia Detection Using Hermitian Basis Functions and kNN Classifier

    by S. Karimifard, A. Ahmadian, M. Khoshnevisan, M. S. Nambakhsh

    This paper presents the results of morphological heart arrhythmia detection based on features of electrocardiography, ECG, signal. These signals are obtained from MIT/BIH arrhythmia database. The ECG beats were first modeled using Hermitian basis functions, (HBF). In this step, the width parameter, sigma, of HBF was optimized to minimize the model error. Then, the feature vector which consists of the parameters of the model is used as an input to k-nearest neighbor, kNN, classifier to examine the efficiency of the model. In our experiments, seven different types of arrhythmias have been considered. We achieved the sensitivity of 99.00% and specificity of 99.84% which are comparable to previous works. These results were obtained in less than 0.6 second which is suitable for real-time diagnosis of heart arrhythmias