Bijan Vosoughi-Vahdat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bijan Vosoughi-Vahdat has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Mohammad Bagher Shamsollahi
Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran
6 shared publications - Behnam Molaee-Ardekani
Inserm, U642, 35000 Rennes, France
4 shared publications - Eric Wodey
Laboratoire Traitement du Signal et de l'Image INSERM : U642Université Rennes ILTSI, Campus de Beaulieu, Université de Rennes 1, 263 Avenue du Général Leclerc - CS 74205 - 35042 Rennes Cedex,FR
4 shared publications - Lotfi Senhadji
Université de Rennes, Rennes, France
4 shared publications - S. M. E. Sahraeian
Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran
2 shared publications - S. R. Mousavi
Sharif Univ Technol, Sch Elect Engn, Biomed Signal & Image Proc Lab BiSIPL, Tehran, Iran
2 shared publications
Latest Publications
- 1 December 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21566097,p. 1-4
Epileptic Seizure Detection using AR Model on EEG Signals
This study presents a new method for epilepsy detection based on autoregressive (AR) estimation of EEG signals. In this method, optimum order for AR model is determined by Bayesian Information Criterion (BIC) and then AR parameters of EEG signals (from EEG data set of epilepsy center of the University of Bonn, Germany) and their sub-bands (created with the help of wavelet decomposition) are extracted based on it. These parameters are used as a feature to classify the EEG signals into Healthy, Interictal (seizure free) and Ictal (during a seizure) groups using multilayer perceptron (MLP) classifier. Correct classification scores at the range of 91% to 96% reveals the potential of our approach for epilepsy detection.
- 1 December 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21566097,p. 1-4
Epileptic Seizure Detection using AR Model on EEG Signals
This study presents a new method for epilepsy detection based on autoregressive (AR) estimation of EEG signals. In this method, optimum order for AR model is determined by Bayesian Information Criterion (BIC) and then AR parameters of EEG signals (from EEG data set of epilepsy center of the University of Bonn, Germany) and their sub-bands (created with the help of wavelet decomposition) are extracted based on it. These parameters are used as a feature to classify the EEG signals into Healthy, Interictal (seizure free) and Ictal (during a seizure) groups using multilayer perceptron (MLP) classifier. Correct classification scores at the range of 91% to 96% reveals the potential of our approach for epilepsy detection.
- 1 December 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21627843,p. 894-899
Error Study of EIT Inverse Problem Solution Using Neural Networks
Electrical Impedance Tomography (EIT) is a visualization of the internal electric conductivity of an object using measurements performed on its surfaces. As an Inverse problem, the solution can be approximated by means of Artificial Neural Networks. In this paper, an Artificial Neural Network solution to this Inverse Problem is presented. Based on the electrical voltage and current measurements on the boundary of the object, the conductivity distribution has been found and the resulting error is calculated. The error is compared for different Neural Network architectures to detect and minimize the errors caused by the solution method. Also, different Neural Networks were tested in the noisy and noiseless conditions to reach the suitable architecture for each case and investigate the measurement error and noise effects. Other than overall error of the whole circuit, distribution of error in different areas of the object is analyzed.
- 1 December 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21627843,p. 894-899
Error Study of EIT Inverse Problem Solution Using Neural Networks
Electrical Impedance Tomography (EIT) is a visualization of the internal electric conductivity of an object using measurements performed on its surfaces. As an Inverse problem, the solution can be approximated by means of Artificial Neural Networks. In this paper, an Artificial Neural Network solution to this Inverse Problem is presented. Based on the electrical voltage and current measurements on the boundary of the object, the conductivity distribution has been found and the resulting error is calculated. The error is compared for different Neural Network architectures to detect and minimize the errors caused by the solution method. Also, different Neural Networks were tested in the noisy and noiseless conditions to reach the suitable architecture for each case and investigate the measurement error and noise effects. Other than overall error of the whole circuit, distribution of error in different areas of the object is analyzed.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 16 (1094687X) , 1294-1297
Delta waves differently modulate high frequency components of EEG oscillations in various unconsciousness levels
In this paper we investigate the modulation properties of high frequency EEG activities by delta waves during various depth of anesthesia. We show that slow and fast delta waves (0-2 Hz and 2-4 Hz respectively) and high frequency components of the EEG (8-20 Hz) are correlated with each other and there is a kind of phase locking between them that varies with depth of anesthesia. Our analyses show that maximum amplitudes of high frequency components of the EEG signal are appeared in different phases of slow and fast delta waves when the concentration of Desflurane and Propofol anesthetic agents varies in a patient. There are some slight differences in using slow and fast components of delta waves. For instance, when depth of anesthesia changes, biphasic responses of the EEG have more influences on results of the fast delta wave method. In addition, this method obtains more robust and less noisy results compared with the slow delta wave method. Since phase angle between fast EEG oscillations and delta waves indicates the status of information processing in the brain and it changes in various unconsciousness levels, it may improve the performance of other classic methods of determining depth of anesthesia.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 16 (1094687X) , 1294-1297
Delta waves differently modulate high frequency components of EEG oscillations in various unconsciousness levels
In this paper we investigate the modulation properties of high frequency EEG activities by delta waves during various depth of anesthesia. We show that slow and fast delta waves (0-2 Hz and 2-4 Hz respectively) and high frequency components of the EEG (8-20 Hz) are correlated with each other and there is a kind of phase locking between them that varies with depth of anesthesia. Our analyses show that maximum amplitudes of high frequency components of the EEG signal are appeared in different phases of slow and fast delta waves when the concentration of Desflurane and Propofol anesthetic agents varies in a patient. There are some slight differences in using slow and fast components of delta waves. For instance, when depth of anesthesia changes, biphasic responses of the EEG have more influences on results of the fast delta wave method. In addition, this method obtains more robust and less noisy results compared with the slow delta wave method. Since phase angle between fast EEG oscillations and delta waves indicates the status of information processing in the brain and it changes in various unconsciousness levels, it may improve the performance of other classic methods of determining depth of anesthesia.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1083-1086
A New Strategy for Providing QoS in IEEE 802.16 Standard
This article presents a new QoS architecture for IEEE 802.16 Broadband Wireless MAN. The newly proposed strategy of providing QoS in packet-based networks via IEEE 802.16 has been analyzed. A mapping rule for providing layer 2.5(MPLS protocol) and MAC layer has been proposed. A fast signaling mechanism has been designed to provide QoS in Point to Multipoint (PMP) mode. Although IEEE 802.16 standards define different mechanisms to provide Quality of Service requirements, it is the responsibility of the developers to obtain efficient designs. In this paper, we introduce a novel architecture for providing QoS requirements such as bandwidth utilization and delay. Simulation result shows the high performance of our architecture for traffic classes defined by the standard.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1083-1086
A New Strategy for Providing QoS in IEEE 802.16 Standard
This article presents a new QoS architecture for IEEE 802.16 Broadband Wireless MAN. The newly proposed strategy of providing QoS in packet-based networks via IEEE 802.16 has been analyzed. A mapping rule for providing layer 2.5(MPLS protocol) and MAC layer has been proposed. A fast signaling mechanism has been designed to provide QoS in Point to Multipoint (PMP) mode. Although IEEE 802.16 standards define different mechanisms to provide Quality of Service requirements, it is the responsibility of the developers to obtain efficient designs. In this paper, we introduce a novel architecture for providing QoS requirements such as bandwidth utilization and delay. Simulation result shows the high performance of our architecture for traffic classes defined by the standard.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 439-445
A New Approach to Assembly Level Programming
In assembly level programming we need to know the mnemonic of each assembly instruction. But it is not so easy to remember mnemonics of all instructions, while the instruction set of Pentium processor includes 280 instructions. In this paper we introduce a new programming approach to assembly level programming in which most important assembly instructions (about 100 instructions) can be substituted for simple equivalents. These equivalent instructions are based on simple familiar operators and make a large simplification in assembly programming. This new language has a free format structure and hence is called Free Format Assembly Language. Evaluating the performance of this language using a developed VC++ program has shown that it is a good substitute for current assembly language.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 439-445
A New Approach to Assembly Level Programming
In assembly level programming we need to know the mnemonic of each assembly instruction. But it is not so easy to remember mnemonics of all instructions, while the instruction set of Pentium processor includes 280 instructions. In this paper we introduce a new programming approach to assembly level programming in which most important assembly instructions (about 100 instructions) can be substituted for simple equivalents. These equivalent instructions are based on simple familiar operators and make a large simplification in assembly programming. This new language has a free format structure and hence is called Free Format Assembly Language. Evaluating the performance of this language using a developed VC++ program has shown that it is a good substitute for current assembly language.
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2006 (1557170X) , 6221-6224
Designing a planar vector field to investigate the role of a slow variable in an enhanced mean-field model during general anesthesia
Local mean-field models (MFMs) describe regional brain activities by some connected differential equations. In an overall view, constituting variables of these differential equations can be divided to very fast, fast and slow variables. In this article we propose a method that can be used to determine role of a slow variable in behavior of MFMs. Very fast variables can be adiabatically removed from the equations. Isoclines of fast and slow variables and their corresponding vector field can provide valuable information about model behavior and role of the slow variable in it. The vector field of our interested MFM that is an enhanced MFM designed specially for general anesthesia, is a 3D field (one slow and two fast variables) and it is not so convenient for visually inspecting the role of the slow variable in this model. To afford this problem we design a 2D (planar) vector filed that only considers the slow variable and one of the fast variables
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2006 (1557170X) , 6221-6224
Designing a planar vector field to investigate the role of a slow variable in an enhanced mean-field model during general anesthesia
Local mean-field models (MFMs) describe regional brain activities by some connected differential equations. In an overall view, constituting variables of these differential equations can be divided to very fast, fast and slow variables. In this article we propose a method that can be used to determine role of a slow variable in behavior of MFMs. Very fast variables can be adiabatically removed from the equations. Isoclines of fast and slow variables and their corresponding vector field can provide valuable information about model behavior and role of the slow variable in it. The vector field of our interested MFM that is an enhanced MFM designed specially for general anesthesia, is a 3D field (one slow and two fast variables) and it is not so convenient for visually inspecting the role of the slow variable in this model. To afford this problem we design a 2D (planar) vector filed that only considers the slow variable and one of the fast variables
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 6221-6224
Designing a planar vector field to investigate the role of a slow variable in an enhanced mean-field model during general anesthesia
Local mean-field models (MFMs) describe regional brain activities by some connected differential equations. In an overall view, constituting variables of these differential equations can be divided to very fast, fast and slow variables. In this article we propose a method that can be used to determine role of a slow variable in behavior of MFMs. Very fast variables can be adiabatically removed from the equations. Isoclines of fast and slow variables and their corresponding vector field can provide valuable information about model behavior and role of the slow variable in it. The vector field of our interested MFM that is an enhanced MFM designed specially for general anesthesia, is a 3D field (one slow and two fast variables) and it is not so convenient for visually inspecting the role of the slow variable in this model. To afford this problem we design a 2D (planar) vector filed that only considers the slow variable and one of the fast variables
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 6221-6224
Designing a planar vector field to investigate the role of a slow variable in an enhanced mean-field model during general anesthesia
Local mean-field models (MFMs) describe regional brain activities by some connected differential equations. In an overall view, constituting variables of these differential equations can be divided to very fast, fast and slow variables. In this article we propose a method that can be used to determine role of a slow variable in behavior of MFMs. Very fast variables can be adiabatically removed from the equations. Isoclines of fast and slow variables and their corresponding vector field can provide valuable information about model behavior and role of the slow variable in it. The vector field of our interested MFM that is an enhanced MFM designed specially for general anesthesia, is a 3D field (one slow and two fast variables) and it is not so convenient for visually inspecting the role of the slow variable in this model. To afford this problem we design a 2D (planar) vector filed that only considers the slow variable and one of the fast variables
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21627843,p. 685-690
Design and Simulation of a Life Detection System Based on Detection of the Heart Beat Using Doppler Frequency
The ability and how to use a microwave life-detection system to search for the humans buried under earthquake rubble or laid behind various barriers has been investigated. Based on the behavior of a human under multiple layers of barriers and the detection capability of the microwave tools a system has been proposed. This system operating at 1150 MHz can remotely detect the movement of the heart of the trapped alive people. The operation principle is based on detection of the Doppler frequency shift of the electromagnetic wave reflected from the periodic moving part of a living human body such as the heart. In this paper, various parts of a microwave life-detection system such as patch antenna, directional coupler, band-pass microstrip filter, power amplifier, and low noise amplifier, are simulated using ADS2003A and Microwave Office software. The practical notes for realization of the system and of each part have been recommended. In addition, through using the simulated system, an overall systematic performance of a complete life detection system has been investigated
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21627843,p. 685-690
Design and Simulation of a Life Detection System Based on Detection of the Heart Beat Using Doppler Frequency
The ability and how to use a microwave life-detection system to search for the humans buried under earthquake rubble or laid behind various barriers has been investigated. Based on the behavior of a human under multiple layers of barriers and the detection capability of the microwave tools a system has been proposed. This system operating at 1150 MHz can remotely detect the movement of the heart of the trapped alive people. The operation principle is based on detection of the Doppler frequency shift of the electromagnetic wave reflected from the periodic moving part of a living human body such as the heart. In this paper, various parts of a microwave life-detection system such as patch antenna, directional coupler, band-pass microstrip filter, power amplifier, and low noise amplifier, are simulated using ADS2003A and Microwave Office software. The practical notes for realization of the system and of each part have been recommended. In addition, through using the simulated system, an overall systematic performance of a complete life detection system has been investigated