CBClaus J. Burkhardt

Claus J. Burkhardt

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Claus J. Burkhardt has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • FIBSEM Analysis of Interfaces Between Hard Technical Devices and Soft Neuronal Tissue

    by Antje Biesemeier, Birgit Schröppel, Wilfried Nisch, Claus J. Burkhardt

  • Open Access

    Strain-dependent effects of clinical echovirus 30 outbreak isolates at the blood-CSF barrier

    by Tobias Dahm, Ortwin Adams, Sindy Boettcher, Sabine Diedrich, Vasily Morozov, Grant Hansman, Petra Fallier-Becker, Sebastian Schädler, Claus J. Burkhardt, Christel Weiss, et al.

    Echovirus (E) 30 (E-30) meningitis is characterized by neuroinflammation involving immune cell pleocytosis at the protective barriers of the central nervous system (CNS). In this context, infection of the blood-cerebrospinal fluid barrier (BCSFB), which has been demonstrated to be involved in enteroviral CNS pathogenesis, may affect the tight junction (TJ) and adherens junction (AJ) function and morphology. We used an in vitro human choroid plexus epithelial (HIBCPP) cell model to investigate the effect of three clinical outbreak strains (13-311, 13-759, and 14-397) isolated in Germany in 2013, and compared them to E-30 Bastianni. Conducting transepithelial electrical resistance (TEER), paracellular dextran flux measurement, quantitative real-time polymerase chain reaction (qPCR), western blot, and immunofluorescence analysis, we investigated TJ and AJ function and morphology as well as strain-specific E-30 infection patterns. Additionally, transmission electron and focused ion beam microscopy electron microscopy (FIB-SEM) was used to evaluate the mode of leukocyte transmigration. Genome sequencing and phylogenetic analyses were performed to discriminate potential genetic differences among the outbreak strains. We observed a significant strain-dependent decrease in TEER with strains E-30 Bastianni and 13-311, whereas paracellular dextran flux was only affected by E-30 Bastianni. Despite strong similarities among the outbreak strains in replication characteristics and particle distribution, strain 13-311 was the only outbreak isolate revealing comparable disruptive effects on TJ (Zonula Occludens (ZO) 1 and occludin) and AJ (E-cadherin) morphology to E-30 Bastianni. Notwithstanding significant junctional alterations upon E-30 infection, we observed both para- and transcellular leukocyte migration across HIBCPP cells. Complete genome sequencing revealed differences between the strains analyzed, but no explicit correlation with the observed strain-dependent effects on HIBCPP cells was possible. The findings revealed distinct E-30 strain-specific effects on barrier integrity and junctional morphology. Despite E-30-induced barrier alterations leukocyte trafficking did not exclusively occur via the paracellular route.


  • Open Access

    Batch Fabrication of Three-Dimensional Microelectrode Arrays For The In-Vitro Investigation Of Tissue Slices And 3D Cell Cultures

    by Manuel Martina, Stefan Klaus, Alfred Stett, Thoralf Herrmann, Günther Zeck, Claus Burkhardt

    Motivation Three dimensional microelectrode arrays pose a valuable tool for the in-vitro investigation of acute tissue slices [1,2]. The reason for this is a dead-cell layer, which occurs due to the preparation of tissue slices and dampens the electrical signal when using planar electrodes. 3D MEAs can overcome the dead-cell layer by penetrating the tissue and moving the active electrode array in direct proximity to the living cells. Furthermore, three dimensional cell cultures become an increasingly hot topic and are subject of more and more investigations [3,4]. Here, a 3D MEA can be applied to measure signals, preferable in different defined heights from the MEA surface. A microelectrode array combining planar and 3D electrodes, with heights ranging from some ten micrometers to a hundred micrometer, can be a valuable tool to progress in this field of research. Here, we present a batch fabrication process, which allows to combine planar electrodes and 3D electrodes with tunable geometry. Material and Methods A process scheme of the fabrication is depicted in Figure 1. First, a silicon-on-glass wafer (consisting of a 50 µm thick silicon layer bonded to a thick glass wafer) is coated with a 50 nm thick silicon nitride layer. The silicon nitride layer is structured by optical lithography into square masks, where the electrode tips will be located. The mask size correlates to the later tip height. After anisotropic etching in potassium hydroxide, the majority of the silicon is removed, yielding a transparent substrate with 3D silicon structures. From here, structuring into a MEA is done by standard processes. During the final step, namely the deposition of the electrode material, height and size of the active electrode area is determined. Results and Discussion Following the developed process, an electrode array with 50 µm high tips is fabricated. Figure 2 shows SEM images of the finished 3D electrodes. The active electrode area, consisting of a fractal titanium nitride layer is located at the upper 20 µm, respectively 15 µm. The aspect ratio (tip height / base diameter) of the structures is measured to 2 and given by the silicon crystal orientation and mask shape. The apex angle is measured to 28°, with a tip radius of 1 µm. This geometry should be well suited for tissue penetration. The developed process possess several advantages over already reported ways to fabricate 3D MEAs, e.g. the isotropic wet etching of glass or the dry etching of SU-8 resist for structure fabrication. Structures fabricated using a silicon-on-glass wafer are completely chemically inert in organic solvents (which are used in lithography processes), mechanically stable during fabrication as well as in application and provide an aspect ratio which cannot be achieved by isotropic wet etching. Conclusions and Outlook We developed a stable and batch process compatible way to fabricate MEAs with 3D electrodes. Although the electrode aspect ratio is fixed, tip height, tip distance and the size of the active electrode area can be tuned to one’s needs. The fabrication of these MEAs utilizes parallel processing and allows to produce these substrate in high numbers to affordable prices. Electrophysiological measurements with these MEAs are currently conducted. In the future, tip geometry and aspect ratio can be further tuned by adapting the mask shape. With proper mask geometry and orientation, triangular tips with apex angles below 25° (known from AFM probes) can be fabricated. It might be possible to fabricate tips with heights of 100 µm and more by using a silicon-on-glass wafer with a thicker silicon layer. Figure Legend Figure 1: Process scheme for the fabrication of an electrode array, combining planar electrodes and 3D electrodes of different heights. Figure 2: SEM images of 50 µm high tips with different sized active electrode areas (red). References: [1] M. O. Heuschkel et al., Journal of Neuroscience Methods 114, 135-148 (2002) [2] S. Röhler et al., Microelectronic Engineering 98, 453-457 (2012) [3] Y. Torisawa et al., Biomaterials 26, 2165-2172 (2015) [4] M. Jang et al., Biomicrofluidics 9, 034113 (2015)

  • Open Access

    Development Of A Microelectrode Array With Semitransparent Carbon Nanotube Electrodes for In-Vitro Applications And Optogenetics

    by Martina Manuel, Besca Kathrin, Kshirsagar Pranoti, Buckenmaier Sandra, Schneider Kerstin, Fleischer Monika, Kern Dieter, Kraushaar Udo, Stett Alfred, Burkhardt Claus

    Motivation Commonly microelectrode materials are selected in consideration of their electrical interface properties, chemical stability and biocompatibility. With these points in mind, there is a small set of standard microelectrode materials available, namely gold, platinum and titanium nitride. Although there are some carbon materials, e.g. PEDOT:PSS, graphite and diamond, none of these offer a reasonable optical transparency. However, in several applications electrode transparency is an integral necessity. For example culture chambers (wells), microfluidic channels and fluid in-/outlets are built on top of MEA substrates and thus, optical imaging from the top with high resolution is impractical. Here, transparent electrodes allow the observation of cell cultures and tissue from the bottom of the well [1]. Furthermore, in the field of optogenetics transparent electrodes enable light stimulation of the cells in the very contact with the electrode through the substrate, as demonstrated by the CLEAR device [2]. There, an all transparent microelectrode array was fabricated out of graphene and successfully utilized. Here, we present a transparent microelectrode array for in-vitro applications, which is based on a thin layer of carbon nanotubes as electrode interface. Materials and Methods A MEA substrate was fabricated utilizing indium-tin-oxide conducting paths and silicon oxide insulator with established cleanroom processes. After opening the electrodes and connection pads by reactive ion etching an ultra-thin catalyst layer of nickel (around 1 nm to 5 nm) is deposited by PVD. After lift-off, thermal CNT deposition is performed in a mixed ammonia-acetylene atmosphere [3]. Substrate transparency after different process steps is measured using an UV-vis spectrometer on reference substrates and impedance measurements in PBS are performed using a MCS MEA2100 system and a platinum reference electrode. For cell culture experiments, ventricular myocytes were isolated from 14 days old embryonic chick hearts as previously described [4]. Field action potentials (fAP) of spontaneously beating cells were recorded after five days in culture at 37°C, 5% CO2. Results and Discussion Following the described process, MEAs with transparent microelectrodes were fabricated. It was observed, that the thickness of the nickel catalyst layer and the CNT height are the critical factors which determine the morphology and thus the optical transparency of the electrode layer. Optimal parameters were found to be 5 mins of pretreatment with 200 sccm ammonia at 3 mbar at 550°C followed by CNT synthesis for 5 mins in 200 sccm ammonia / 200 sccm acetylene at 5 mbar at 550°C. The total transparency of the final CNT electrodes was measured to be around 40% in the visible range, see Figure 1. The impedance of these MEAs with electrode diameters of 30 µm was measured to be in the range of 50 kO to 100 kO at 1 kHz in PBS buffer. SEM images showed a layer of CNTs with heights of around 200 nm. Cultivation of ventricular myocytes on the fabricated MEAs was successful. fAPs could be measured with a good signal-to-noise ratio. The basic noise level of the electrodes was approximately ± 10 µV while the biological signals reached peak-to-peak amplitudes of up to 2,5 mV. The advantage of these MEAs in comparison to the standard MEAs is the transparency of the electrodes which allows visualizing the plated cells directly on the respective electrodes, see Figure 2. Conclusions and Outlook We developed a process to fabricate transparent microelectrodes based on carbon nanotubes. These MEAs were successfully used to measure field action potentials from ventricular myocytes and allowed optical cell visualization from the bottom through the electrode. We will further improve the transparency and electrical properties of these MEAs and investigate other carbon materials, e.g. graphene, for their feasibility as transparent electrode material. Experiments to test the applicability of the fabricated MEAs for optogenetic measurements and for calcium imaging are planned. Figure 1: Measured transparency on a reference substrate after different process steps. Figure 2: SEM image of a CNT microelectrode (left) and optical image of cardio cells through the electrodes and conducting lines (right). An electrode and its conducting line is dotted in red for visualization. Signals in the right image are 1.5 s long and peak-to-peak is cropped to 200 µV to show repolarization peak. References: [1] K.Y. Kwon et al., IEEE Trans Biomed Circuits Syst. 7, 593–600 (2013) [2] D.-W. Park et al., Nature Communications 5, 5258 (2014) [3] K. Schneider et al., 12th Conference on Nanotechnology (IEEE-NANO), 1–5 (2012) [4] P. Connolly et al., Biosensors and Bioelectronics 5(3), 223–234 (1990)