Dirk Schäfer
Dirk Schäfer has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Michael Grass
Philips Technologie GmbH Forschungslaboratorien, Rontgenstrasse 24-26, D-22335 Hamburg, Germany
3 shared publicationsBabak Movassaghi
2 shared publications- Michael Grass
Innovative Technologies, Philips, Hamburg, Germany
2 shared publications - Volker Rasche
Department of Internal Medicine II, Ulm University Medical Center, Ulm, Germany
2 shared publications - Afshin Gangi
Department of Interventional Radiology, University Hospital Strasbourg, Strasbourg, France
1 shared publication - Anindita Chatterjea
Image Guided Therapy Systems, Philips Healthcare, Best, The Netherlands
1 shared publication
Latest Publications
- Open Access
Accuracy Assessment of Percutaneous Pedicle Screw Placement Using Cone Beam Computed Tomography with Metal Artifact Reduction
Metal artifact reduction (MAR) algorithms are used with cone beam computed tomography (CBCT) during augmented reality surgical navigation for minimally invasive pedicle screw instrumentation. The aim of this study was to assess intra- and inter-observer reliability of pedicle screw placement and to compare the perception of baseline image quality (NoMAR) with optimized image quality (MAR). CBCT images of 24 patients operated on for degenerative spondylolisthesis using minimally invasive lumbar fusion were analyzed retrospectively. Images were treated using NoMAR and MAR by an engineer, thus creating 48 randomized files, which were then independently analyzed by 3 spine surgeons and 3 radiologists. The Gertzbein and Robins classification was used for screw accuracy rating, and an image quality scale rated the clarity of pedicle screw and bony landmark depiction. Intra-class correlation coefficients (ICC) were calculated. NoMAR and MAR led to similarly good intra-observer (ICC > 0.6) and excellent inter-observer (ICC > 0.8) assessment reliability of pedicle screw placement accuracy. The image quality scale showed more variability in individual image perception between spine surgeons and radiologists (ICC range 0.51–0.91). This study indicates that intraoperative screw positioning can be reliably assessed on CBCT for augmented reality surgical navigation when using optimized image quality. Subjective image quality was rated slightly superior for MAR compared to NoMAR.
Open AccessAccuracy Assessment of Percutaneous Pedicle Screw Placement Using Cone Beam Computed Tomography with Metal Artifact Reduction
Metal artifact reduction (MAR) algorithms are used with cone beam computed tomography (CBCT) during augmented reality surgical navigation for minimally invasive pedicle screw instrumentation. The aim of this study was to assess intra- and inter-observer reliability of pedicle screw placement and to compare the perception of baseline image quality (NoMAR) with optimized image quality (MAR). CBCT images of 24 patients operated on for degenerative spondylolisthesis using minimally invasive lumbar fusion were analyzed retrospectively. Images were treated using NoMAR and MAR by an engineer, thus creating 48 randomized files, which were then independently analyzed by 3 spine surgeons and 3 radiologists. The Gertzbein and Robins classification was used for screw accuracy rating, and an image quality scale rated the clarity of pedicle screw and bony landmark depiction. Intra-class correlation coefficients (ICC) were calculated. NoMAR and MAR led to similarly good intra-observer (ICC > 0.6) and excellent inter-observer (ICC > 0.8) assessment reliability of pedicle screw placement accuracy. The image quality scale showed more variability in individual image perception between spine surgeons and radiologists (ICC range 0.51–0.91). This study indicates that intraoperative screw positioning can be reliably assessed on CBCT for augmented reality surgical navigation when using optimized image quality. Subjective image quality was rated slightly superior for MAR compared to NoMAR.
- Open Access
- 1 September 2015
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 1 (1) , 283-285
Three-dimensional anisotropic regularization for limited angle tomography
Limited angle tomography is a challenging task in medical imaging. Due to practical limitations during the image acquisition, the sinogram is recorded incompletely and thus the quality of the reconstruction is deteriorated by streak artifacts. These artifacts are characterized by fast changes of the local intensity gradients and increase the total variation (TV). Generally, an energy functional is optimized which leads to a minimized Total Variation Minimization (TVM). As an outcome, noise and artifacts are reduced while edges are preserved. Anyway, often the orientation of the streak artifacts is not considered at all. Therefore, anisotropic regularization is used to reduce noise and distortions under specific directions.
- 1 September 2015
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 1 (1) , 283-285
Open AccessThree-dimensional anisotropic regularization for limited angle tomography
Limited angle tomography is a challenging task in medical imaging. Due to practical limitations during the image acquisition, the sinogram is recorded incompletely and thus the quality of the reconstruction is deteriorated by streak artifacts. These artifacts are characterized by fast changes of the local intensity gradients and increase the total variation (TV). Generally, an energy functional is optimized which leads to a minimized Total Variation Minimization (TVM). As an outcome, noise and artifacts are reduced while edges are preserved. Anyway, often the orientation of the streak artifacts is not considered at all. Therefore, anisotropic regularization is used to reduce noise and distortions under specific directions.
- 1 April 2014
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 38 (3) , 224-231
Model based 3D CS-catheter tracking from 2D X-ray projections: Binary versus attenuation models
- 1 April 2014
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 38 (3) , 224-231
Model based 3D CS-catheter tracking from 2D X-ray projections: Binary versus attenuation models
- Open Access
- 1 January 2012
- Published by Springer Nature
- Vol. 15, 634-641
Limited Angle C-Arm Tomography and Segmentation for Guidance of Atrial Fibrillation Ablation Procedures
Angiographic projections of the left atrium (LA) and the pulmonary veins (PV) acquired with a rotational C-arm system are used for 3D image reconstruction and subsequent automatic segmentation of the LA and PV to be used as roadmap in fluoroscopy guided LA ablation procedures. Acquisition of projections at high oblique angulations may be problematic due to increased collision danger of the detector with the right shoulder of the patient. We investigate the accuracy of image reconstruction and model based roadmap segmentation using limited angle C-arm tomography. The reduction of the angular range from 200°to 150°leads only to a moderate increase of the segmentation error from 1.5 mm to 2.0 mm if matched conditions are used in the segmentation, i.e. the model based segmentation is trained on images reconstructed with the same angular range as the test images. The minor decrease in accuracy may be outweighed by clinical workflow improvement, gained when large C-arm angulations can be avoided.
- 1 January 2012
- Published by Springer Nature
- Vol. 15, 634-641
Open AccessLimited Angle C-Arm Tomography and Segmentation for Guidance of Atrial Fibrillation Ablation Procedures
Angiographic projections of the left atrium (LA) and the pulmonary veins (PV) acquired with a rotational C-arm system are used for 3D image reconstruction and subsequent automatic segmentation of the LA and PV to be used as roadmap in fluoroscopy guided LA ablation procedures. Acquisition of projections at high oblique angulations may be problematic due to increased collision danger of the detector with the right shoulder of the patient. We investigate the accuracy of image reconstruction and model based roadmap segmentation using limited angle C-arm tomography. The reduction of the angular range from 200°to 150°leads only to a moderate increase of the segmentation error from 1.5 mm to 2.0 mm if matched conditions are used in the segmentation, i.e. the model based segmentation is trained on images reconstructed with the same angular range as the test images. The minor decrease in accuracy may be outweighed by clinical workflow improvement, gained when large C-arm angulations can be avoided.
- 20 July 2011
- Published by Wiley in Medical Physics
- Vol. 38 (S1) , S85-S94
FBP and BPF reconstruction methods for circular X-ray tomography with off-center detector
Purpose: Circular scanning with an off-center planar detector is an acquisition scheme that allows to save detector area while keeping a large field of view (FOV). Several filtered back-projection (FBP) algorithms have been proposed earlier. The purpose of this work is to present two newly developed back-projection filtration (BPF) variants and evaluate the image quality of these methods compared to the existing state-of-the-art FBP methods.Methods: The first new BPF algorithm applies redundancy weighting of overlapping opposite projections before differentiation in a single projection. The second one uses the Katsevich-type differentiation involving two neighboring projections followed by redundancy weighting and back-projection. An averaging scheme is presented to mitigate streak artifacts inherent to circular BPF algorithms along the Hilbert filter lines in the off-center transaxial slices of the reconstructions. The image quality is assessed visually on reconstructed slices of simulated and clinical data. Quantitative evaluation studies are performed with the Forbild head phantom by calculating root-mean-squared-deviations (RMSDs) to the voxelized phantom for different detector overlap settings and by investigating the noise resolution trade-off with a wire phantom in the full detector and off-center scenario.Results: The noise-resolution behavior of all off-center reconstruction methods corresponds to their full detector performance with the best resolution for the FDK based methods with the given imaging geometry. With respect to RMSD and visual inspection, the proposed BPF with Katsevich-type differentiation outperforms all other methods for the smallest chosen detector overlap of about 15 mm. The best FBP method is the algorithm that is also based on the Katsevich-type differentiation and subsequent redundancy weighting. For wider overlap of about 40–50 mm, these two algorithms produce similar results outperforming the other three methods. The clinical case with a detector overlap of about 17 mm confirms these results.Conclusions: The BPF-type reconstructions with Katsevich differentiation are widely independent of the size of the detector overlap and give the best results with respect to RMSD and visual inspection for minimal detector overlap. The increased homogeneity will improve correct assessment of lesions in the entire field of view.
- 20 July 2011
- Published by Wiley in Medical Physics
- Vol. 38 (S1) , S85-S94
FBP and BPF reconstruction methods for circular X-ray tomography with off-center detector
Purpose: Circular scanning with an off-center planar detector is an acquisition scheme that allows to save detector area while keeping a large field of view (FOV). Several filtered back-projection (FBP) algorithms have been proposed earlier. The purpose of this work is to present two newly developed back-projection filtration (BPF) variants and evaluate the image quality of these methods compared to the existing state-of-the-art FBP methods.Methods: The first new BPF algorithm applies redundancy weighting of overlapping opposite projections before differentiation in a single projection. The second one uses the Katsevich-type differentiation involving two neighboring projections followed by redundancy weighting and back-projection. An averaging scheme is presented to mitigate streak artifacts inherent to circular BPF algorithms along the Hilbert filter lines in the off-center transaxial slices of the reconstructions. The image quality is assessed visually on reconstructed slices of simulated and clinical data. Quantitative evaluation studies are performed with the Forbild head phantom by calculating root-mean-squared-deviations (RMSDs) to the voxelized phantom for different detector overlap settings and by investigating the noise resolution trade-off with a wire phantom in the full detector and off-center scenario.Results: The noise-resolution behavior of all off-center reconstruction methods corresponds to their full detector performance with the best resolution for the FDK based methods with the given imaging geometry. With respect to RMSD and visual inspection, the proposed BPF with Katsevich-type differentiation outperforms all other methods for the smallest chosen detector overlap of about 15 mm. The best FBP method is the algorithm that is also based on the Katsevich-type differentiation and subsequent redundancy weighting. For wider overlap of about 40–50 mm, these two algorithms produce similar results outperforming the other three methods. The clinical case with a detector overlap of about 17 mm confirms these results.Conclusions: The BPF-type reconstructions with Katsevich differentiation are widely independent of the size of the detector overlap and give the best results with respect to RMSD and visual inspection for minimal detector overlap. The increased homogeneity will improve correct assessment of lesions in the entire field of view.
- 31 May 2006
- Published by Elsevier in Academic Radiology
- Vol. 13 (5) , 644-651
Three-dimensional X-ray Coronary Angiography in the Porcine Model: A Feasibility Study
- 31 May 2006
- Published by Elsevier in Academic Radiology
- Vol. 13 (5) , 644-651
Three-dimensional X-ray Coronary Angiography in the Porcine Model: A Feasibility Study
- 31 May 2006
- Published by Elsevier in Academic Radiology
- Vol. 13 (5) , 630-640
Automatic Selection of the Optimal Cardiac Phase for Gated Three-dimensional Coronary x-ray Angiography
- 31 May 2006
- Published by Elsevier in Academic Radiology
- Vol. 13 (5) , 630-640
Automatic Selection of the Optimal Cardiac Phase for Gated Three-dimensional Coronary x-ray Angiography