Patricia Rosales
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Patricia Rosales has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Susana Marcos
University of Rochester
4 shared publications - Adrian Glasser
From the College of Optometry, University of Houston, Houston, Texas, USA
1 shared publication - Alberto de Castro
Instituto de Óptica “Daza de Valdés,” Consejo Superior de Investigaciones Científicas, Madrid, Spain
1 shared publication - Carlos Dorronsoro
Laboratory of Visual Optics and Biophotonics, Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Serrano 121, 28006 Madrid, Spain
1 shared publication Ignacio Jiménez-Alfaro
1 shared publication- Lourdes Llorente
Instituto de Óptica Daza de Valdés, Consejo Superior de Investigaciones Científicas, Madrid, Spain
1 shared publication
Latest Publications
- 1 January 2010
- Published by Optica Publishing Group
- p. FMD3
Performance of aspheric IOLs
Aspheric IOLs induce negative spherical aberration in order to emulate young crystalline lenses. We present optical aberrations in pseudophakic eyes, the effect of misalignment on optical performance, using customized eye models, and new aspheric designs.
- 1 January 2010
- Published by Optica Publishing Group
- p. FMD3
Performance of aspheric IOLs
Aspheric IOLs induce negative spherical aberration in order to emulate young crystalline lenses. We present optical aberrations in pseudophakic eyes, the effect of misalignment on optical performance, using customized eye models, and new aspheric designs.
- Open Access
- 1 January 2008
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 8 (1) , 18
Changes in crystalline lens radii of curvature and lens tilt and decentration during dynamic accommodation in rhesus monkeys
Dynamic changes in crystalline lens radii of curvature and lens tilt and decentration were measured during centrally stimulated accommodation in four iridectomized eyes of two adolescent rhesus monkeys. Phakometry measurements were performed dynamically using a custom-built, video-based, Purkinje-image instrument. Lens anterior and posterior radii were calculated from reflections of paired light sources from the ocular surfaces (Purkinje images PI, PIII, and PIV). Lens tilt and decentration were calculated assuming linearity between Purkinje image positions, eye rotation, lens tilt, and decentration. Because the monkey eyes were iridectomized, Purkinje images were referred to the mid-point of the double first Purkinje image (PI). Mean unaccommodated values of anterior and posterior lens radii of curvature were 11.11 ± 1.58 mm and −6.64 ± 0.62 mm, respectively, and these decreased relatively linearly with accommodation in all eyes, at a rate of 0.48 ± 0.14 mm/D and 0.17 ± 0.03 mm/D for anterior and posterior lens surfaces, respectively. Tilt and decentration did not change significantly with accommodation except for tilt around the horizontal axis, which changed at a rate of 0.147 ± 0.25 deg/D. These results are important to fully characterize accommodation in rhesus monkeys.
- 1 January 2008
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 8 (1) , 18
Open AccessChanges in crystalline lens radii of curvature and lens tilt and decentration during dynamic accommodation in rhesus monkeys
Dynamic changes in crystalline lens radii of curvature and lens tilt and decentration were measured during centrally stimulated accommodation in four iridectomized eyes of two adolescent rhesus monkeys. Phakometry measurements were performed dynamically using a custom-built, video-based, Purkinje-image instrument. Lens anterior and posterior radii were calculated from reflections of paired light sources from the ocular surfaces (Purkinje images PI, PIII, and PIV). Lens tilt and decentration were calculated assuming linearity between Purkinje image positions, eye rotation, lens tilt, and decentration. Because the monkey eyes were iridectomized, Purkinje images were referred to the mid-point of the double first Purkinje image (PI). Mean unaccommodated values of anterior and posterior lens radii of curvature were 11.11 ± 1.58 mm and −6.64 ± 0.62 mm, respectively, and these decreased relatively linearly with accommodation in all eyes, at a rate of 0.48 ± 0.14 mm/D and 0.17 ± 0.03 mm/D for anterior and posterior lens surfaces, respectively. Tilt and decentration did not change significantly with accommodation except for tilt around the horizontal axis, which changed at a rate of 0.147 ± 0.25 deg/D. These results are important to fully characterize accommodation in rhesus monkeys.
- 1 January 2007
- Published by Optica Publishing Group in Optics Express
- Vol. 15 (5) , 2204-2218
Customized computer models of eyes with intraocular lenses
We compared experimental wave aberrations in pseudophakic eyes with aspheric intraocular lenses (IOLs) to simulate aberrations from numerical ray tracing on customized computer eye models using corneal topography, angle λ, ocular biometry, IOL geometry, and IOL tilt and decentration measured on the same eyes. We found high correlations between real and simulated aberrations even for the eye with only the cornea, and these increased on average when the IOL geometry and position were included. Relevant individual aberrations were well predicted by the complete eye model. Corneal spherical aberration and horizontal coma were compensated by the IOL, and in 58.3% of the cases IOL tilt and decentration contributed to compensation of horizontal coma. We conclude that customized computer eye models are a good representation of real eyes with IOLs and allow understanding of the relative contribution of optical, geometrical and surgically-related factors to image quality. Corneal spherical aberration is reduced by aspheric IOLs, although other corneal high order aberrations are still a major contributor to total aberrations in pseudophakic eyes. Tilt and decentration of the IOLs represent a relatively minor contribution of the overall optical quality of the eye.
- 1 January 2007
- Published by Optica Publishing Group in Optics Express
- Vol. 15 (5) , 2204-2218
Customized computer models of eyes with intraocular lenses
We compared experimental wave aberrations in pseudophakic eyes with aspheric intraocular lenses (IOLs) to simulate aberrations from numerical ray tracing on customized computer eye models using corneal topography, angle λ, ocular biometry, IOL geometry, and IOL tilt and decentration measured on the same eyes. We found high correlations between real and simulated aberrations even for the eye with only the cornea, and these increased on average when the IOL geometry and position were included. Relevant individual aberrations were well predicted by the complete eye model. Corneal spherical aberration and horizontal coma were compensated by the IOL, and in 58.3% of the cases IOL tilt and decentration contributed to compensation of horizontal coma. We conclude that customized computer eye models are a good representation of real eyes with IOLs and allow understanding of the relative contribution of optical, geometrical and surgically-related factors to image quality. Corneal spherical aberration is reduced by aspheric IOLs, although other corneal high order aberrations are still a major contributor to total aberrations in pseudophakic eyes. Tilt and decentration of the IOLs represent a relatively minor contribution of the overall optical quality of the eye.
- Open Access
- 1 August 2006
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 6 (10) , 5
Crystalline lens radii of curvature from Purkinje and Scheimpflug imaging
We present a comparison between measurements of the radius of the anterior and posterior lens surface, which was performed using corrected Scheimpflug imaging and Purkinje imaging in the same group of participants (46 for the anterior lens, and 34 for the posterior lens). Comparisons were also made as a function of accommodation (0 to 7 D) in a subset of 11 eyes. Data were captured and processed using laboratory prototypes and custom processing algorithms [for optical and geometrical distortion correction in the Scheimpflug system and using either equivalent mirror (EM) or merit function (MF) methods for Purkinje]. We found statistically significant differences in 4 of 46 eyes for the anterior lens radius, and 10 of 34 eyes for the posterior radius (using the MF and individual biometric data to process the Purkinje images). For the anterior lens, the agreement increases using individual biometry as opposed to biometric data from a model eye. For the posterior lens, the agreement increases using the MF as opposed to the EM method. For the changes during accommodation, no significant difference between the two techniques was found. In conclusion, the results of the cross-validation using the Scheimpflug and Purkinje imaging technique show that both techniques provide comparable lens radii and similar changes with accommodation. Purkinje tends to overestimate posterior lens radius, whereas pupil size limits the acquisition of posterior lens data with the Scheimpflug camera. Computer simulations using the Scheimpflug data as input show that the consistent slight overestimation of the posterior lens radius using Purkinje imaging can be partly attributed to the asphericity of the lens surface.
- 1 August 2006
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 6 (10) , 5
Open AccessCrystalline lens radii of curvature from Purkinje and Scheimpflug imaging
We present a comparison between measurements of the radius of the anterior and posterior lens surface, which was performed using corrected Scheimpflug imaging and Purkinje imaging in the same group of participants (46 for the anterior lens, and 34 for the posterior lens). Comparisons were also made as a function of accommodation (0 to 7 D) in a subset of 11 eyes. Data were captured and processed using laboratory prototypes and custom processing algorithms [for optical and geometrical distortion correction in the Scheimpflug system and using either equivalent mirror (EM) or merit function (MF) methods for Purkinje]. We found statistically significant differences in 4 of 46 eyes for the anterior lens radius, and 10 of 34 eyes for the posterior radius (using the MF and individual biometric data to process the Purkinje images). For the anterior lens, the agreement increases using individual biometry as opposed to biometric data from a model eye. For the posterior lens, the agreement increases using the MF as opposed to the EM method. For the changes during accommodation, no significant difference between the two techniques was found. In conclusion, the results of the cross-validation using the Scheimpflug and Purkinje imaging technique show that both techniques provide comparable lens radii and similar changes with accommodation. Purkinje tends to overestimate posterior lens radius, whereas pupil size limits the acquisition of posterior lens data with the Scheimpflug camera. Computer simulations using the Scheimpflug data as input show that the consistent slight overestimation of the posterior lens radius using Purkinje imaging can be partly attributed to the asphericity of the lens surface.
- 1 March 2006
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 23 (3) , 509-520
Phakometry and lens tilt and decentration using a custom-developed Purkinje imaging apparatus: validation and measurements
We present a Purkinje imaging system for phakometry and measurement of tilt and decentration of crystalline and intraocular lenses (IOLs). Crystalline lens radii of curvature were estimated by using both a merit function and the equivalent mirror approaches. Tilts and decentrations were estimated by using Phillips’s linear analysis. We present a complete validation of the technique through exhaustive computer simulations and control experiments, and measurements in 17 normal eyes (mean age ) and nine postcataract surgery eyes (mean age ). Crystalline lens radii ranged from 12.7 to 8.81 mm and from to for anterior and posterior surfaces, respectively. Crystalline lens tilt ranged from 2.8 to horizontally and from 2.58 to vertically. Crystalline lens decentration ranged from 0.09 to 0.45 mm horizontally and from 0.09 to vertically. IOL tilt ranged from 3.6 to horizontally and from 5.97 to vertically. IOL decentration ranged from 0.53 to horizontally and from 0.13 to vertically.- 1 March 2006
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 23 (3) , 509-520
Phakometry and lens tilt and decentration using a custom-developed Purkinje imaging apparatus: validation and measurements
We present a Purkinje imaging system for phakometry and measurement of tilt and decentration of crystalline and intraocular lenses (IOLs). Crystalline lens radii of curvature were estimated by using both a merit function and the equivalent mirror approaches. Tilts and decentrations were estimated by using Phillips’s linear analysis. We present a complete validation of the technique through exhaustive computer simulations and control experiments, and measurements in 17 normal eyes (mean age ) and nine postcataract surgery eyes (mean age ). Crystalline lens radii ranged from 12.7 to 8.81 mm and from to for anterior and posterior surfaces, respectively. Crystalline lens tilt ranged from 2.8 to horizontally and from 2.58 to vertically. Crystalline lens decentration ranged from 0.09 to 0.45 mm horizontally and from 0.09 to vertically. IOL tilt ranged from 3.6 to horizontally and from 5.97 to vertically. IOL decentration ranged from 0.53 to horizontally and from 0.13 to vertically.