M. Henze
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
M. Henze has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- J. Doll
Forschungsschwerpunkt Radiologische Diagnostik und Therapie, Deutsches Krebsforschungszentrum (DKFZ), Heidelberg, Deutschland
4 shared publications U Haberkorn
4 shared publicationsU. Haberkorn
4 shared publicationsA. Hunt
3 shared publicationsJ Debus
3 shared publicationsJ. Schröder
3 shared publications
Latest Publications
- 24 March 2006
- Published by Georg Thieme Verlag KG in Klinische Neurophysiologie
- Vol. 37 (01) , A193
Neural correlates of cognition deficits in mild cognitive impairment and Alzheimer's disease as assessed by the CERAD neuropsychological test battery
Objective: Alzheimer's disease (AD) is characterized by severe cognitive deficits involving different cognitive domains such as memory decline, language deficits, and apraxia. Mild cognitive impairment (MCI) is supposed to represent a potential preclinical stage of the disease where distinct cognitive deficits occur. Although, memory impairment has been addressed in recent neuroimaging studies the neural substrates of most cognitive deficits in AD, which can be reliable be assessed by using the neuropsychological test battery of the Consortium to Establish a Register for Alzheimer's Disease (CERAD), remain unresolved. To this concern, positron emission tomography (PET) has been proofed an adequate method for unrevealing the neural substrates of cognitive dysfunctions. Method: 75 patients with AD and MCI were investigated with 18F-2-fluoro-2-deoxy-D-glucose (FDG) PET. In all patients, the neuropsychological test battery of the CERAD was applied. Using statistical parametric mapping significant correlations were calculated to assess the association of cerebral glucose metabolism and neuropsychological test performance. Results: Significant correlations between memory test scores and activation of temporo-frontal and cingulate cortices occurred. Verbal fluency and naming scores were significantly correlated with predominantly left temporo-parietal and frontal cortices whereas constructional praxis test scores were significantly correlated with left temporal and right frontal cortices. Irrespective of domain, delayed memory performance was associated with a network including rather frontal association cortices. Conclusions: The findings demonstrate that neuropsychological deficits as assessed by the CERAD involve different cerebral sites and thus underline the clinical validity of this clinical instrument.
- 24 March 2006
- Published by Georg Thieme Verlag KG in Klinische Neurophysiologie
- Vol. 37 (01) , A193
Neural correlates of cognition deficits in mild cognitive impairment and Alzheimer's disease as assessed by the CERAD neuropsychological test battery
Objective: Alzheimer's disease (AD) is characterized by severe cognitive deficits involving different cognitive domains such as memory decline, language deficits, and apraxia. Mild cognitive impairment (MCI) is supposed to represent a potential preclinical stage of the disease where distinct cognitive deficits occur. Although, memory impairment has been addressed in recent neuroimaging studies the neural substrates of most cognitive deficits in AD, which can be reliable be assessed by using the neuropsychological test battery of the Consortium to Establish a Register for Alzheimer's Disease (CERAD), remain unresolved. To this concern, positron emission tomography (PET) has been proofed an adequate method for unrevealing the neural substrates of cognitive dysfunctions. Method: 75 patients with AD and MCI were investigated with 18F-2-fluoro-2-deoxy-D-glucose (FDG) PET. In all patients, the neuropsychological test battery of the CERAD was applied. Using statistical parametric mapping significant correlations were calculated to assess the association of cerebral glucose metabolism and neuropsychological test performance. Results: Significant correlations between memory test scores and activation of temporo-frontal and cingulate cortices occurred. Verbal fluency and naming scores were significantly correlated with predominantly left temporo-parietal and frontal cortices whereas constructional praxis test scores were significantly correlated with left temporal and right frontal cortices. Irrespective of domain, delayed memory performance was associated with a network including rather frontal association cortices. Conclusions: The findings demonstrate that neuropsychological deficits as assessed by the CERAD involve different cerebral sites and thus underline the clinical validity of this clinical instrument.
- 24 March 2006
- Published by Georg Thieme Verlag KG in Klinische Neurophysiologie
- Vol. 37 (01) , A101
Neural correlates of executive function in Alzheimer's disease and mild cognitive impairment
Objective: Executive dysfunction in Alzheimer's disease (AD) is associated with delusions, agitation and disinhibition, rapid progression and care dependency. We correlated resting cerebral glucose metabolism in Alzheimer's disease (AD) and mild cognitive impairment (MCI) with scores on the Trail Making Test (TMT) as a measure of executive function. Methods: Ten patients with AD, 10 patients with mild cognitive impairment (MCI) and 14 controls were included. We compared resting cerebral glucose metabolism in patients with that in controls and correlated TMT scores with cerebral glucose metabolism. Neuropsychological correlates of the TMT were also investigated. Results: Patients had reduced frontotemporoparietal and posterior cingulate metabolism compared to controls. TMT-A correlated with left middle frontal, TMT-B and TMT-Q with right middle frontal and TMT-B with right precentral glucose metabolism. TMT-A and TMT-B scores correlated (pConclusions: PET and neuropsychological correlates indicate that executive function measured by TMT is frontal lobe mediated and demands working memory. The neuropsychological correlates of the tasks confirm the complexity of the task.
- 24 March 2006
- Published by Georg Thieme Verlag KG in Klinische Neurophysiologie
- Vol. 37 (01) , A101
Neural correlates of executive function in Alzheimer's disease and mild cognitive impairment
Objective: Executive dysfunction in Alzheimer's disease (AD) is associated with delusions, agitation and disinhibition, rapid progression and care dependency. We correlated resting cerebral glucose metabolism in Alzheimer's disease (AD) and mild cognitive impairment (MCI) with scores on the Trail Making Test (TMT) as a measure of executive function. Methods: Ten patients with AD, 10 patients with mild cognitive impairment (MCI) and 14 controls were included. We compared resting cerebral glucose metabolism in patients with that in controls and correlated TMT scores with cerebral glucose metabolism. Neuropsychological correlates of the TMT were also investigated. Results: Patients had reduced frontotemporoparietal and posterior cingulate metabolism compared to controls. TMT-A correlated with left middle frontal, TMT-B and TMT-Q with right middle frontal and TMT-B with right precentral glucose metabolism. TMT-A and TMT-B scores correlated (pConclusions: PET and neuropsychological correlates indicate that executive function measured by TMT is frontal lobe mediated and demands working memory. The neuropsychological correlates of the tasks confirm the complexity of the task.
- 1 January 2006
- Published by Japan Society of Histochemistry & Cytochemistry in Nuklearmedizin-Nuclear Medicine
- Vol. 45 (1) , 49-56
[Comparison of diagnostic accuracy of (18)F-FDG PET, (123)I-IMT- and (99m)Tc-MIBI SPECT: evaluation of tumour progression in irradiated low grade astrocytomas].
To evaluates the diagnostic accuracy of the SPECT-tracers 3-(123)I-alpha-methyl-L-tyrosine (IMT) and (99m)Tc(I)- hexakis(2-methoxyisobutylisonitrile) (MIBI) as well as the PET-tracer 2-(18)F-2-deoxyglucose (FDG) for detecting tumour progression in irradiated low grade astrocytomas (LGA). We examined 91 patients (56 males; 35 females; 44.7 +/- 11.5 years), initially suffering from histologically proven LGAs (mean WHO grade II) and treated by stereotactic radiotherapy (59.0 +/- 4.6 Gy). On average 21.9 +/- 11.2 months after radiotherapy, patients presented new Gd-DTPA enhancing lesions on MRI, which did not allow a differentiation between progressive tumour (PT) and non-PT (nPT) at this point of time. PET scans (n = 82) were acquired 45 min after injection of 208 +/- 32 MBq FDG. SPECT scans started 10 min after injection of 269 +/- 73 MBq IMT (n = 68) and 15 min after injection of 706 +/- 63 MBq MIBI (n = 34). Lesions were classified as PT and nPT based on prospective follow-up (clinically, MRI) for 17.2 +/- 9.9 months after PET/SPECT. Lesion-to-normal ratios (L/N) were calculated using contra lateraly mirrored reference regions for the SPECT examinations and reference regions in the contra lateral grey (GM) and white matter (WM) for FDG PET. Ratios were evaluated by Receiver Operating Characteristic (ROC) analysis. In the patient groups nPT and PT, L/N ratios for FDG (GS) were 0.6 +/- 0.3 vs. 1.2 +/- 0.5 (p = 0.003), for FDG (WS) 1.2 +/- 0.4 vs. 2.6 +/- 0.4 (p < 0.001), for IMT 1.1 +/- 0.1 vs. 1.8 +/- 0.4 (p < 0.001) and for MIBI 1.6 +/- 0.7 vs. 2.6 +/- 2.2 (p = 0.554). Areas under the non-parametric ROC-curves were: 0.738 +/- 0.059 for FDG (GS), 0.790 +/- 0.057 for FDG (WS), 0.937 +/- 0.037 for IMT and 0.564 +/- 0.105 for MIBI. MIBI-SPECT examinations resulted in a low accuracy and especially in a poor sensitivity even at modest specificity values. A satisfying diagnostic accuracy was reached with FDG PET. Using WM as reference region for FDG PET, a slightly higher AUC as compared to GM was calculated. IMT yielded the best ROC characteristics and the highest diagnostic accuracy for differentiating between PT and nPT in irradiated LGA.
- 1 January 2006
- Published by Japan Society of Histochemistry & Cytochemistry in Nuklearmedizin-Nuclear Medicine
- Vol. 45 (1) , 49-56
[Comparison of diagnostic accuracy of (18)F-FDG PET, (123)I-IMT- and (99m)Tc-MIBI SPECT: evaluation of tumour progression in irradiated low grade astrocytomas].
To evaluates the diagnostic accuracy of the SPECT-tracers 3-(123)I-alpha-methyl-L-tyrosine (IMT) and (99m)Tc(I)- hexakis(2-methoxyisobutylisonitrile) (MIBI) as well as the PET-tracer 2-(18)F-2-deoxyglucose (FDG) for detecting tumour progression in irradiated low grade astrocytomas (LGA). We examined 91 patients (56 males; 35 females; 44.7 +/- 11.5 years), initially suffering from histologically proven LGAs (mean WHO grade II) and treated by stereotactic radiotherapy (59.0 +/- 4.6 Gy). On average 21.9 +/- 11.2 months after radiotherapy, patients presented new Gd-DTPA enhancing lesions on MRI, which did not allow a differentiation between progressive tumour (PT) and non-PT (nPT) at this point of time. PET scans (n = 82) were acquired 45 min after injection of 208 +/- 32 MBq FDG. SPECT scans started 10 min after injection of 269 +/- 73 MBq IMT (n = 68) and 15 min after injection of 706 +/- 63 MBq MIBI (n = 34). Lesions were classified as PT and nPT based on prospective follow-up (clinically, MRI) for 17.2 +/- 9.9 months after PET/SPECT. Lesion-to-normal ratios (L/N) were calculated using contra lateraly mirrored reference regions for the SPECT examinations and reference regions in the contra lateral grey (GM) and white matter (WM) for FDG PET. Ratios were evaluated by Receiver Operating Characteristic (ROC) analysis. In the patient groups nPT and PT, L/N ratios for FDG (GS) were 0.6 +/- 0.3 vs. 1.2 +/- 0.5 (p = 0.003), for FDG (WS) 1.2 +/- 0.4 vs. 2.6 +/- 0.4 (p < 0.001), for IMT 1.1 +/- 0.1 vs. 1.8 +/- 0.4 (p < 0.001) and for MIBI 1.6 +/- 0.7 vs. 2.6 +/- 2.2 (p = 0.554). Areas under the non-parametric ROC-curves were: 0.738 +/- 0.059 for FDG (GS), 0.790 +/- 0.057 for FDG (WS), 0.937 +/- 0.037 for IMT and 0.564 +/- 0.105 for MIBI. MIBI-SPECT examinations resulted in a low accuracy and especially in a poor sensitivity even at modest specificity values. A satisfying diagnostic accuracy was reached with FDG PET. Using WM as reference region for FDG PET, a slightly higher AUC as compared to GM was calculated. IMT yielded the best ROC characteristics and the highest diagnostic accuracy for differentiating between PT and nPT in irradiated LGA.
- 1 September 2005
- Published by Georg Thieme Verlag KG in Pharmacopsychiatry
- Vol. 38 (05) , A102
Neural correlates of executive function in mild cognitive impairment and Alzheimer's disease–an FDG-PET study
Executive dysfunction in Alzheimer’s disease (AD) is associated with delusions, agitation and disinhibition, rapid progression and care dependency. We correlated resting cerebral glucose metabolism in Alzheimer’s disease (AD) and mild cognitive impairment (MCI) with scores on the Trail Making Test (TMT) as a measure of executive function. Methods: Ten patients with AD, 10 patients with mild cognitive impairment (MCI) and 14 controls were included. We compared cerebral glucose metabolism in patients with that in controls and correlated TMT scores with cerebral glucose metabolism. Neuropsychological correlates of the TMT were also investigated. Results: Patients had reduced frontotemporoparietal and posterior cingulate metabolism compared to controls. TMT-A correlated with left middle frontal, TMT-B and TMT-Q with right middle frontal and TMT-B with right precentral glucose metabolism. TMT-A and TMT-B scores correlated with word fluency and recall subtests of the CERAD neuropsychological test battery, TMT-Q with delayed constructional praxis scores. Conclusions: PET and neuropsychological correlates indicate that executive function is frontal lobe mediated and demands working memory. The neuropsychological correlates of the tasks confirm the complexity of the task.
- 1 September 2005
- Published by Georg Thieme Verlag KG in Pharmacopsychiatry
- Vol. 38 (05) , A102
Neural correlates of executive function in mild cognitive impairment and Alzheimer's disease–an FDG-PET study
Executive dysfunction in Alzheimer’s disease (AD) is associated with delusions, agitation and disinhibition, rapid progression and care dependency. We correlated resting cerebral glucose metabolism in Alzheimer’s disease (AD) and mild cognitive impairment (MCI) with scores on the Trail Making Test (TMT) as a measure of executive function. Methods: Ten patients with AD, 10 patients with mild cognitive impairment (MCI) and 14 controls were included. We compared cerebral glucose metabolism in patients with that in controls and correlated TMT scores with cerebral glucose metabolism. Neuropsychological correlates of the TMT were also investigated. Results: Patients had reduced frontotemporoparietal and posterior cingulate metabolism compared to controls. TMT-A correlated with left middle frontal, TMT-B and TMT-Q with right middle frontal and TMT-B with right precentral glucose metabolism. TMT-A and TMT-B scores correlated with word fluency and recall subtests of the CERAD neuropsychological test battery, TMT-Q with delayed constructional praxis scores. Conclusions: PET and neuropsychological correlates indicate that executive function is frontal lobe mediated and demands working memory. The neuropsychological correlates of the tasks confirm the complexity of the task.
- 1 June 2004
- Published by Japan Society of Histochemistry & Cytochemistry in Nuklearmedizin-Nuclear Medicine
- Vol. 43 (3) , 72-8
[High resolution reconstruction of PET images using the iterative OSEM algorithm].
Improvement of the spatial resolution in positron emission tomography (PET) by incorporation of the image-forming characteristics of the scanner into the process of iterative image reconstruction. All measurements were performed at the whole-body PET system ECAT EXACT HR(+) in 3D mode. The acquired 3D sinograms were sorted into 2D sinograms by means of the Fourier rebinning (FORE) algorithm, which allows the usage of 2D algorithms for image reconstruction. The scanner characteristics were described by a spatially variant line-spread function (LSF), which was determined from activated copper-64 line sources. This information was used to model the physical degradation processes in PET measurements during the course of 2D image reconstruction with the iterative OSEM algorithm. To assess the performance of the high-resolution OSEM algorithm, phantom measurements performed at a cylinder phantom, the hotspot Jaszczack phantom, and the 3D Hoffmann brain phantom as well as different patient examinations were analyzed. Scanner characteristics could be described by a Gaussian-shaped LSF with a full-width at half-maximum increasing from 4.8 mm at the center to 5.5 mm at a radial distance of 10.5 cm. Incorporation of the LSF into the iteration formula resulted in a markedly improved resolution of 3.0 and 3.5 mm, respectively. The evaluation of phantom and patient studies showed that the high-resolution OSEM algorithm not only lead to a better contrast resolution in the reconstructed activity distributions but also to an improved accuracy in the quantification of activity concentrations in small structures without leading to an amplification of image noise or even the occurrence of image artifacts. The spatial and contrast resolution of PET scans can markedly be improved by the presented image restauration algorithm, which is of special interest for the examination of both patients with brain disorders and small animals.
- 1 June 2004
- Published by Japan Society of Histochemistry & Cytochemistry in Nuklearmedizin-Nuclear Medicine
- Vol. 43 (3) , 72-8
[High resolution reconstruction of PET images using the iterative OSEM algorithm].
Improvement of the spatial resolution in positron emission tomography (PET) by incorporation of the image-forming characteristics of the scanner into the process of iterative image reconstruction. All measurements were performed at the whole-body PET system ECAT EXACT HR(+) in 3D mode. The acquired 3D sinograms were sorted into 2D sinograms by means of the Fourier rebinning (FORE) algorithm, which allows the usage of 2D algorithms for image reconstruction. The scanner characteristics were described by a spatially variant line-spread function (LSF), which was determined from activated copper-64 line sources. This information was used to model the physical degradation processes in PET measurements during the course of 2D image reconstruction with the iterative OSEM algorithm. To assess the performance of the high-resolution OSEM algorithm, phantom measurements performed at a cylinder phantom, the hotspot Jaszczack phantom, and the 3D Hoffmann brain phantom as well as different patient examinations were analyzed. Scanner characteristics could be described by a Gaussian-shaped LSF with a full-width at half-maximum increasing from 4.8 mm at the center to 5.5 mm at a radial distance of 10.5 cm. Incorporation of the LSF into the iteration formula resulted in a markedly improved resolution of 3.0 and 3.5 mm, respectively. The evaluation of phantom and patient studies showed that the high-resolution OSEM algorithm not only lead to a better contrast resolution in the reconstructed activity distributions but also to an improved accuracy in the quantification of activity concentrations in small structures without leading to an amplification of image noise or even the occurrence of image artifacts. The spatial and contrast resolution of PET scans can markedly be improved by the presented image restauration algorithm, which is of special interest for the examination of both patients with brain disorders and small animals.
- 1 January 2004
- Published by Georg Thieme Verlag KG in Nuklearmedizin-Nuclear Medicine
- Vol. 43 (03) , 72-78
High resolution reconstruction of PET images using the iterative OSEM algorithm
Aim: Improvement of the spatial resolution in positron emission tomography (PET) by incorporation of the image-forming characteristics of the scanner into the process of iterative image reconstruction. Methods: All measurements were performed at the whole-body PET system ECAT EXACT HR+ in 3D mode. The acquired 3D sinograms were sorted into 2D sinograms by means of the Fourier rebinning (FORE) algorithm, which allows the usage of 2D algorithms for image reconstruction. The scanner characteristics were described by a spatially variant line-spread function (LSF), which was determined from activated copper-64 line sources. This information was used to model the physical degradation processes in PET measurements during the course of 2D image reconstruction with the iterative OSEM algorithm. To assess the performance of the high-resolution OSEM algorithm, phantom measurements performed at a cylinder phantom, the hotspot Jaszczack phantom, and the 3D Hoffmann brain phantom as well as different patient examinations were analyzed. Results: Scanner characteristics could be described by a Gaussian-shaped LSF with a full-width at half-maximum increasing from 4.8 mm at the center to 5.5 mm at a radial distance of 10.5 cm. Incorporation of the LSF into the iteration formula resulted in a markedly improved resolution of 3.0 and 3.5 mm, respectively. The evaluation of phantom and patient studies showed that the high-resolution OSEM algorithm not only lead to a better contrast resolution in the reconstructed activity distributions but also to an improved accuracy in the quantification of activity concentrations in small structures without leading to an amplification of image noise or even the occurrence of image artifacts. Conclusion: The spatial and contrast resolution of PET scans can markedly be improved by the presented image restauration algorithm, which is of special interest for the examination of both patients with brain disorders and small animals. Ziel: Verbesserung der räumlichen Auflösung in der Positronenemissionstomographie (PET) durch Berücksichtigung der Abbildungseigenschaften des Scanners bei der iterativen Bildrekonstruktion. Methodik: Alle Messungen erfolgten am GanzkörperPET-System ECAT EXACT HR+ im 3D-Modus. Die 3D-Sinogramme wurden mit dem Fourier-Rebinning-Algorithmus (FORE) in 2D-Sinogramme umsortiert, so dass für die Bildrekonstruktion 2D-Algorithmen eingesetzt wurden. Die Abbildungseigenschaften des Scanners wurden durch eine räumlich veränderliche Linienabbildungsfunktion (LSF) charakterisiert, die mit Kupfer-64-Linienquellen vermessen wurde. Diese Information wurde verwendet, um die physikalischen Prozesse, die bei der PET-Mes-sung zur Auflösungsverschlechterung führen, bei der 2D-Bildrekonstruktion mit dem iterativen OSEM-Algorithmus zu berücksichtigen. Um die Abbildungseigenschaften des hochauflösenden OSEM-Algorithmus zu evaluieren, wurden Messungen an einem Zylinder-, dem Hotspot-Jaszczack- und dem Hoffmann-3D-Brain-Phantom sowie Patientenuntersuchungen analysiert. Ergebnisse: Die Abbildungscharakteristika des Scanners konnten durch eine Gauss-förmige LSF beschrieben werden, deren Halbwertsbreite von 4,8 mm im Zentrum auf 5,5 mm im radialen Abstand von 10,5 cm zunimmt. Durch die Einbeziehung der LSF in die Iterations-formel konnte die räumliche Auflösung über das betrachtete Gesichtsfeld auf 3,0 bzw. 3,5 mm verbessert werden. Die Auswertung ergab, dass der hochauflösende OSEM-Algorithmus zu einer besseren Kontrastauflösung in den Aktivitätsverteilungen führt und zu einer erhöhten Genauigkeit bei der Quantifizierung von Aktivitätskonzentrationen in kleinen Strukturen, ohne dass es zu einem Anstieg des Bildrauschens oder gar zur Ausbildung von Artefakten kommt. Schlussfolgerung: Die Orts- und Kontrastauflösung von PET-Bildern kann durch den evaluierten Restaurationsalgorithmus deutlich verbessert werden, was für die Untersuchung von Patienten mit Hirnerkrankungen als auch von Kleintieren von Interesse ist.
- 1 January 2004
- Published by Georg Thieme Verlag KG in Nuklearmedizin-Nuclear Medicine
- Vol. 43 (03) , 72-78
High resolution reconstruction of PET images using the iterative OSEM algorithm
Aim: Improvement of the spatial resolution in positron emission tomography (PET) by incorporation of the image-forming characteristics of the scanner into the process of iterative image reconstruction. Methods: All measurements were performed at the whole-body PET system ECAT EXACT HR+ in 3D mode. The acquired 3D sinograms were sorted into 2D sinograms by means of the Fourier rebinning (FORE) algorithm, which allows the usage of 2D algorithms for image reconstruction. The scanner characteristics were described by a spatially variant line-spread function (LSF), which was determined from activated copper-64 line sources. This information was used to model the physical degradation processes in PET measurements during the course of 2D image reconstruction with the iterative OSEM algorithm. To assess the performance of the high-resolution OSEM algorithm, phantom measurements performed at a cylinder phantom, the hotspot Jaszczack phantom, and the 3D Hoffmann brain phantom as well as different patient examinations were analyzed. Results: Scanner characteristics could be described by a Gaussian-shaped LSF with a full-width at half-maximum increasing from 4.8 mm at the center to 5.5 mm at a radial distance of 10.5 cm. Incorporation of the LSF into the iteration formula resulted in a markedly improved resolution of 3.0 and 3.5 mm, respectively. The evaluation of phantom and patient studies showed that the high-resolution OSEM algorithm not only lead to a better contrast resolution in the reconstructed activity distributions but also to an improved accuracy in the quantification of activity concentrations in small structures without leading to an amplification of image noise or even the occurrence of image artifacts. Conclusion: The spatial and contrast resolution of PET scans can markedly be improved by the presented image restauration algorithm, which is of special interest for the examination of both patients with brain disorders and small animals. Ziel: Verbesserung der räumlichen Auflösung in der Positronenemissionstomographie (PET) durch Berücksichtigung der Abbildungseigenschaften des Scanners bei der iterativen Bildrekonstruktion. Methodik: Alle Messungen erfolgten am GanzkörperPET-System ECAT EXACT HR+ im 3D-Modus. Die 3D-Sinogramme wurden mit dem Fourier-Rebinning-Algorithmus (FORE) in 2D-Sinogramme umsortiert, so dass für die Bildrekonstruktion 2D-Algorithmen eingesetzt wurden. Die Abbildungseigenschaften des Scanners wurden durch eine räumlich veränderliche Linienabbildungsfunktion (LSF) charakterisiert, die mit Kupfer-64-Linienquellen vermessen wurde. Diese Information wurde verwendet, um die physikalischen Prozesse, die bei der PET-Mes-sung zur Auflösungsverschlechterung führen, bei der 2D-Bildrekonstruktion mit dem iterativen OSEM-Algorithmus zu berücksichtigen. Um die Abbildungseigenschaften des hochauflösenden OSEM-Algorithmus zu evaluieren, wurden Messungen an einem Zylinder-, dem Hotspot-Jaszczack- und dem Hoffmann-3D-Brain-Phantom sowie Patientenuntersuchungen analysiert. Ergebnisse: Die Abbildungscharakteristika des Scanners konnten durch eine Gauss-förmige LSF beschrieben werden, deren Halbwertsbreite von 4,8 mm im Zentrum auf 5,5 mm im radialen Abstand von 10,5 cm zunimmt. Durch die Einbeziehung der LSF in die Iterations-formel konnte die räumliche Auflösung über das betrachtete Gesichtsfeld auf 3,0 bzw. 3,5 mm verbessert werden. Die Auswertung ergab, dass der hochauflösende OSEM-Algorithmus zu einer besseren Kontrastauflösung in den Aktivitätsverteilungen führt und zu einer erhöhten Genauigkeit bei der Quantifizierung von Aktivitätskonzentrationen in kleinen Strukturen, ohne dass es zu einem Anstieg des Bildrauschens oder gar zur Ausbildung von Artefakten kommt. Schlussfolgerung: Die Orts- und Kontrastauflösung von PET-Bildern kann durch den evaluierten Restaurationsalgorithmus deutlich verbessert werden, was für die Untersuchung von Patienten mit Hirnerkrankungen als auch von Kleintieren von Interesse ist.
- 1 July 2001
- Vol. 42 (7) , 1053-6
PET imaging of somatostatin receptors using [68GA]DOTA-D-Phe1-Tyr3-octreotide: first results in patients with meningiomas.
Imaging of somatostatin receptors (SSTRs) using [111In]diethylenetriaminepentaacetic-acid-octreotide (DTPAOC) has proven to be helpful in the differentiation of meningiomas, neurinomas or neurofibromas, and metastases as well as in the follow-up of meningiomas. A drawback of the SPECT method is its limited sensitivity in detecting small meningiomas. Because of PET's increased spatial resolution and its ability to absolutely quantify biodistribution, a PET tracer for SSTR imaging would be desirable. 1,4,7,10-tetraazacyclododecane-N,N',N",N"'-tetraacetic-acid-D-Phe1-Tyr3-octreotide (DOTATOC) was labeled using the positron-emitting generator nuclide 68Ga. We acquired dynamic PET images over 120 min after intravenous injection of 175 MBq [68Ga]DOTATOC in 3 patients suffering from 8 meningiomas (WHO I degrees; 7- to 25-mm diameter). Patients' heads had been fixed using individually shaped fiber masks equipped with an external stereotactic localizer system to match PET, CT, and MRI datasets. [68Ga]DOTATOC was rapidly cleared from the blood (half-life alpha, 3.5 min; half-life beta, 63 min). Standardized uptake values (SUVs) of meningiomas increased immediately after injection and reached a plateau 60-120 min after injection (mean SUV, 10.6). No tracer could be found in the surrounding healthy brain tissue. All meningiomas (even the 3 smallest [7- to 8-mm diameter]) showed high tracer uptake and could be visualized clearly. Tracer boundaries showed a good correspondence with the matched CT and MRI images. PET provided valuable additional information regarding the extent of meningiomas located beneath osseous structures, especially at the base of the skull. According to our initial experiences, [68Ga]DOTATOC seems to be a very promising new PET tracer for imaging SSTRs even in small meningiomas, offering excellent imaging properties and a very high tumor-to-background ratio.
- 1 July 2001
- Vol. 42 (7) , 1053-6
PET imaging of somatostatin receptors using [68GA]DOTA-D-Phe1-Tyr3-octreotide: first results in patients with meningiomas.
Imaging of somatostatin receptors (SSTRs) using [111In]diethylenetriaminepentaacetic-acid-octreotide (DTPAOC) has proven to be helpful in the differentiation of meningiomas, neurinomas or neurofibromas, and metastases as well as in the follow-up of meningiomas. A drawback of the SPECT method is its limited sensitivity in detecting small meningiomas. Because of PET's increased spatial resolution and its ability to absolutely quantify biodistribution, a PET tracer for SSTR imaging would be desirable. 1,4,7,10-tetraazacyclododecane-N,N',N",N"'-tetraacetic-acid-D-Phe1-Tyr3-octreotide (DOTATOC) was labeled using the positron-emitting generator nuclide 68Ga. We acquired dynamic PET images over 120 min after intravenous injection of 175 MBq [68Ga]DOTATOC in 3 patients suffering from 8 meningiomas (WHO I degrees; 7- to 25-mm diameter). Patients' heads had been fixed using individually shaped fiber masks equipped with an external stereotactic localizer system to match PET, CT, and MRI datasets. [68Ga]DOTATOC was rapidly cleared from the blood (half-life alpha, 3.5 min; half-life beta, 63 min). Standardized uptake values (SUVs) of meningiomas increased immediately after injection and reached a plateau 60-120 min after injection (mean SUV, 10.6). No tracer could be found in the surrounding healthy brain tissue. All meningiomas (even the 3 smallest [7- to 8-mm diameter]) showed high tracer uptake and could be visualized clearly. Tracer boundaries showed a good correspondence with the matched CT and MRI images. PET provided valuable additional information regarding the extent of meningiomas located beneath osseous structures, especially at the base of the skull. According to our initial experiences, [68Ga]DOTATOC seems to be a very promising new PET tracer for imaging SSTRs even in small meningiomas, offering excellent imaging properties and a very high tumor-to-background ratio.
- 1 May 2001
- Vol. 61 (9) , 3712-7
Immunoscintigraphy with positron emission tomography: gallium-68 chelate imaging of breast cancer pretargeted with bispecific anti-MUC1/anti-Ga chelate antibodies.
Pretargeting techniques that are based on the sequential administrations of bispecific antitumor/antimetal chelate antibodies (BS-MAbs), a blocker to saturate the anti-chelate binding sites of the BS-MAb still present in the circulation, and the radiolabeled chelate are suitable to increase tumor-to-normal tissue contrasts and enable positron emission tomography (PET) as an imaging method. As demonstrated in the nude mouse model, a combination of pretargeted immunoscintigraphy and PET markedly improved the detection of tumor xenografts. With the presented preliminary clinical trial, we attempted to assess the efficacy of pretargeting and PET for breast cancer localization in patients. The BS-MAb used for pretargeting was synthesized from the F(ab')(2) fragments of the anti-MUC1 MAb 12H12, which reacts with the vast majority of breast tumors, and the F(ab') fragments of an anti-gallium (Ga) chelate MAb via a mixed functional chemical linker. For labeling of the Ga-chelate, we used the short-lived positron emitter Ga-68 (t(1/2), 68 min; beta(+), 88%). The dose and time schedule of pretargeting was deduced from previous animal experiments. Ten patients with biopsy-proven, primary breast carcinoma were infused with 10 mg of the BS-MAB: Eighteen h later, they received i.v. injections of 10.7 mg of a blocker and, 15 min later, 9.6 microg of the Ga chelate labeled with 230-300 MBq of (68)GA: PET imaging was started 60-90 min after injection of the (68)Ga chelate. Average tumor-to-blood and tumor:normal breast tissue ratios were 0.9 and 3.0 at 1 h postinjection. Tumor uptake amounted to approximately 0.003% iD/g corresponding to a standard uptake value of approximately 2. Blood clearance of the (68)Ga chelate showed a t(1/2) beta of approximately 100 min. Fourteen of 17 known lesions, averaging 25 +/- 16 mm in size, were clearly visualized as foci of increased activity with PET. No false-positive but three false-negative readings were obtained. An enhanced, bilateral activity uptake in the whole breast parenchyma, found in 4 of the 10 patients, compromised the recognition of these tumor sites. Although the shedding of the MUC1 antigen and the comparatively low tumor affinity of the BS-MAb, common to all anti-mucin MAbs, proved not to be optimal for increasing tumor:tissue ratios with a pretargeting technique, PET imaging offered better sensitivity for the detection of breast cancer at low tumor contrasts than conventional immunoscintigraphy. This could be demonstrated by the clear visualization of tumor sites 10 mm in size, which contrasted only by a factor of 2 from surrounding normal breast tissue.
- 1 May 2001
- Vol. 61 (9) , 3712-7
Immunoscintigraphy with positron emission tomography: gallium-68 chelate imaging of breast cancer pretargeted with bispecific anti-MUC1/anti-Ga chelate antibodies.
Pretargeting techniques that are based on the sequential administrations of bispecific antitumor/antimetal chelate antibodies (BS-MAbs), a blocker to saturate the anti-chelate binding sites of the BS-MAb still present in the circulation, and the radiolabeled chelate are suitable to increase tumor-to-normal tissue contrasts and enable positron emission tomography (PET) as an imaging method. As demonstrated in the nude mouse model, a combination of pretargeted immunoscintigraphy and PET markedly improved the detection of tumor xenografts. With the presented preliminary clinical trial, we attempted to assess the efficacy of pretargeting and PET for breast cancer localization in patients. The BS-MAb used for pretargeting was synthesized from the F(ab')(2) fragments of the anti-MUC1 MAb 12H12, which reacts with the vast majority of breast tumors, and the F(ab') fragments of an anti-gallium (Ga) chelate MAb via a mixed functional chemical linker. For labeling of the Ga-chelate, we used the short-lived positron emitter Ga-68 (t(1/2), 68 min; beta(+), 88%). The dose and time schedule of pretargeting was deduced from previous animal experiments. Ten patients with biopsy-proven, primary breast carcinoma were infused with 10 mg of the BS-MAB: Eighteen h later, they received i.v. injections of 10.7 mg of a blocker and, 15 min later, 9.6 microg of the Ga chelate labeled with 230-300 MBq of (68)GA: PET imaging was started 60-90 min after injection of the (68)Ga chelate. Average tumor-to-blood and tumor:normal breast tissue ratios were 0.9 and 3.0 at 1 h postinjection. Tumor uptake amounted to approximately 0.003% iD/g corresponding to a standard uptake value of approximately 2. Blood clearance of the (68)Ga chelate showed a t(1/2) beta of approximately 100 min. Fourteen of 17 known lesions, averaging 25 +/- 16 mm in size, were clearly visualized as foci of increased activity with PET. No false-positive but three false-negative readings were obtained. An enhanced, bilateral activity uptake in the whole breast parenchyma, found in 4 of the 10 patients, compromised the recognition of these tumor sites. Although the shedding of the MUC1 antigen and the comparatively low tumor affinity of the BS-MAb, common to all anti-mucin MAbs, proved not to be optimal for increasing tumor:tissue ratios with a pretargeting technique, PET imaging offered better sensitivity for the detection of breast cancer at low tumor contrasts than conventional immunoscintigraphy. This could be demonstrated by the clear visualization of tumor sites 10 mm in size, which contrasted only by a factor of 2 from surrounding normal breast tissue.
- 1 February 2001
- Vol. 42 (2) , 317-25
Transfer of the human NaI symporter gene enhances iodide uptake in hepatoma cells.
The characteristic feature of thyroid cells of taking up iodide enables benign thyroid diseases and differentiated thyroid carcinoma to be successfully treated with radioiodide therapy. The transport of iodide across the cell membrane is mediated by the human NaI symporter (hNIS). We therefore investigated whether the accumulation of iodide may be induced by the retroviral transfer of the hNIS gene in nonthyroid tumor cells. With use of a bicistronic retroviral vector for the transfer of the hNIS coding sequence and the hygromycin resistance gene, rat Morris hepatoma (MH3924A) cells were infected with retroviral particles and 32 hNIS-expressing cell lines were generated by hygromycin selection. After incubation of the genetically modified and wild-type hepatoma cells and the rat thyroid cell line FRTL5 with Na125I, the uptake and efflux of iodide were determined. In addition, the iodide distribution in rats bearing wild-type and genetically modified hepatomas was monitored. Genetically modified MH3924A cell lines accumulated up to 235 times more iodide than did noninfected hepatoma cells. The maximal iodide uptake in the cells was observed after 60 min incubation time. Competition experiments in the presence of sodium perchlorate revealed a dose-dependent decrease of iodide uptake (87%-92%). Moreover, carbonyl cyanide p-trifluoromethoxyphenylhydrazone led to a loss of accumulated I- (32%), whereas 4,4'-diisothiocyano-2,2'-disulfonic acid stilbene increased the I- uptake into the cells (22%). However, a rapid efflux of the radioactivity (80%) was observed during the first 10 min after 125I(-)-containing medium had been replaced by nonradioactive medium. In rats, the hNIS-expressing tumors accumulated six times more iodide than did the contralateral wild-type tumor as monitored by scintigraphy. The ex vivo quantitation of the iodide content performed 1 h after tracer administration in 1 g of tumor tissue revealed a 17-fold higher iodide accumulation in the genetically modified tumors. In accordance with the in vitro data, we also observed a rapid efflux of radioactivity from the tumor in vivo. The transduction of the hNIS gene per se is sufficient to induce 125I transport in Morris hepatoma cells in vitro and in vivo. With regard to a therapeutic application, however, additional conditions need to be defined that inhibit the iodide efflux from the tumor cells.
- 1 February 2001
- Vol. 42 (2) , 317-25
Transfer of the human NaI symporter gene enhances iodide uptake in hepatoma cells.
The characteristic feature of thyroid cells of taking up iodide enables benign thyroid diseases and differentiated thyroid carcinoma to be successfully treated with radioiodide therapy. The transport of iodide across the cell membrane is mediated by the human NaI symporter (hNIS). We therefore investigated whether the accumulation of iodide may be induced by the retroviral transfer of the hNIS gene in nonthyroid tumor cells. With use of a bicistronic retroviral vector for the transfer of the hNIS coding sequence and the hygromycin resistance gene, rat Morris hepatoma (MH3924A) cells were infected with retroviral particles and 32 hNIS-expressing cell lines were generated by hygromycin selection. After incubation of the genetically modified and wild-type hepatoma cells and the rat thyroid cell line FRTL5 with Na125I, the uptake and efflux of iodide were determined. In addition, the iodide distribution in rats bearing wild-type and genetically modified hepatomas was monitored. Genetically modified MH3924A cell lines accumulated up to 235 times more iodide than did noninfected hepatoma cells. The maximal iodide uptake in the cells was observed after 60 min incubation time. Competition experiments in the presence of sodium perchlorate revealed a dose-dependent decrease of iodide uptake (87%-92%). Moreover, carbonyl cyanide p-trifluoromethoxyphenylhydrazone led to a loss of accumulated I- (32%), whereas 4,4'-diisothiocyano-2,2'-disulfonic acid stilbene increased the I- uptake into the cells (22%). However, a rapid efflux of the radioactivity (80%) was observed during the first 10 min after 125I(-)-containing medium had been replaced by nonradioactive medium. In rats, the hNIS-expressing tumors accumulated six times more iodide than did the contralateral wild-type tumor as monitored by scintigraphy. The ex vivo quantitation of the iodide content performed 1 h after tracer administration in 1 g of tumor tissue revealed a 17-fold higher iodide accumulation in the genetically modified tumors. In accordance with the in vitro data, we also observed a rapid efflux of radioactivity from the tumor in vivo. The transduction of the hNIS gene per se is sufficient to induce 125I transport in Morris hepatoma cells in vitro and in vivo. With regard to a therapeutic application, however, additional conditions need to be defined that inhibit the iodide efflux from the tumor cells.