SRSelma Uysal Ramadan

Selma Uysal Ramadan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Selma Uysal Ramadan has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Uterine Fibroids, Variants, Mimics: Imaging Findings

    by Selma Uysal Ramadan

    Uterine Fibroids, Variants, Mimics: Imaging Findings - Türk Radyoloji Seminerleri


  • The stylohyoid chain: CT imaging

    by Selma Uysal Ramadan, Dilek Gökharman, Pınar Koşar, Mahmut Kacar, Uğur Koşar


  • Optimisation of contrast medium volume and injection-related factors in CT pulmonary angiography: 64-slice CT study

    by Selma Uysal Ramadan, Pınar Kosar, Iclal Sonmez, Sevilay Karahan, Ugur Kosar

    Objective To compare the image quality of computed tomography pulmonary angiography (CTPA) obtained with the injection of various low doses of contrast medium (CM) with different injection-related factors. Methods A total of 90 patients (42 females, 48 males; 54.3 ± 18.6 years) undergoing CTPA were included. Three CM protocols, each containing 30 patients, were created. Protocols 1, 2 and 3 consisted of a CM of 60 ml, 55 ml and 50 ml, and a bolus trigger level of 120 HU, 90 HU and 75 HU, respectively. Injection was uniphasic for protocols 1 and 2 (flow rate 5 ml/s), and biphasic for protocol 3 (flow rates 5 and 4 ml/s); with saline flushing afterwards. Enhancement was measured in three central and six peripheral pulmonary arteries. Results The mean attenuation value for pulmonary arteries was over 250 HU for all protocols. There was no difference between the attenuation levels with the protocols (p > 0.05). The percentage of pulmonary arteries exceeding optimal attenuation (≥250 HU) showed that protocols 2 and 3 were 90–100% successful (p < 0.05). Conclusion The use of proper injection-related factors during CTPA, such as a low trigger level and a high flow rate with saline injection following a decreased CM volume (55 ml or 50 ml), will enable adequate pulmonary artery contrast enhancement.


  • Sex determination from measurements of the sternum and fourth rib using multislice computed tomography of the chest

    by Selma Uysal Ramadan, Nursel Türkmen, N. Anıl Dolgun, Dilek Gökharman, Ritesh G. Menezes, Mahmut Kacar, Uğur Koşar


  • Assessment of vascularity with color Doppler ultrasound in gynecomastia

    by Selma Uysal Ramadan, Dilek Gokharman, Mahmut Kacar, Pinar Kosar, Ugur Kosar

    The aim of this study was to analyze the presence and type of vascularity with color Doppler ultrasound (CDUS) in gynecomastia, to describe gray-scale ultrasound (US) and CDUS features in different stages of gynecomastia, and to compare these findings with the characteristic US appearances of Tanner stages. A total of 108 breasts of 54 males aged 11-27 years with complaint of gynecomastia and US verification of gynecomastia were evaluated. Each breast was then classified according to Tanner stages. The retroareolar thickness was measured. The breast was divided into three regions (medial, lateral, and retroareolar) and the arterial flow was scored according to the number of regions in which arterial flow was observed. Venous blood flow was scored according to the number of vessels in each breast. Gynecomastia was present in 78 breasts with a retroareolar thickness of 5-31 mm and symptom duration of 1-300 weeks. Fifteen breasts with gynecomastia had no arterial or venous flow. Tanner stages were found to be strongly associated with arterial and venous flow scores, duration of symptoms, and retroareolar thickness (P < 0.001). This study shows that vascular structures should be accepted as a component of gynecomastia. Vascularity in gynecomastia corresponds to progression of breast development, and as the process advances vascularity becomes more prominent.


  • Does the presence of a mesh have an effect on the testicular blood flow after surgical repair of indirect inguinal hernia?

    by Selma Uysal Ramadan, Dilek Gokharman, Isil Tuncbilek, Hilal Ozer, Pinar Kosar, Mahmut Kacar, Selim Temel, Ugur Kosar

    Purpose.: Modern treatment of inguinal hernias includes prosthetic mesh repairs. However, direct contact of the mesh to the vessels in the inguinal canal and perimesh fibrosis may have a negative impact on testicular flow. The aim of this prospective study was to evaluate the effect of mesh implantation/perimesh fibrosis on testicular flow after repair of indirect inguinal hernias (IIHs).Method.: Forty‐eight male patients with unilateral IIH were included. Both testicular parenchyma were assessed using gray‐scale sonography, and color/spectral Doppler sonography was performed to evaluate testicular arterial impedance, perfusion, and venous flow. Measurements were made bilaterally at the level of the inguinal canal 1 day before and at the end of the 2nd month after the operation.Results.: There was no difference in testicular and echotexture perfusion between the hernia and the control sides pre‐ and postoperatively. No venous thrombosis was found. In all groups, resistance index and pulsatility index, measured at 4 levels, were highest in the proximal inguinal canal and lowest at the extratesticular–intrascrotal level (p < 0.05). For all Doppler parameters there was no significant difference between the pre‐ and postoperative measurements on both the hernia and the control sides.Conclusion.: Mesh implantation/perimesh fibrosis does not adversely affect ipsilateral testicular flow. Mesh application is still a safe procedure in male patients in whom testicular function is important. © 2008 Wiley Periodicals, Inc. J Clin Ultrasound, 2009


    • 1 December 2007
      • Vol. 13  (4) , 176-8

    Diffuse stylohyoid chain ossification.

    by Selma Uysal Ramadan, Dilek Gökharman, Mahmut Kaçar, Uğur Koşar

    Clinical symptoms of stylohyoid chain ossification vary from ear pain to dysphagia. It is usually diagnosed coincidentally. Localized ossification of the chain is common, whereas diffuse ossification is rare. Herein, a case with bilateral diffuse stylohyoid chain ossification diagnosed with computed tomography, which was performed in order to evaluate the patient's temporomandibular joint pain, a rare onset of this condition, is discussed.


  • Assessment of the stylohoid chain by 3D-CT

    by Selma Uysal Ramadan, Dilek Gokharman, Işil Tunçbilek, Mahmut Kacar, Pinar Koşar, Uğur Kosar

    Background To assess the variations of stylohyoid chain (SHC) using 3D-CT. Methods We evaluated a total of 200 SHC on the head/neck CT scans of 100 patients (44 females, 56 males, age range 18–73 years). All of the patients had been scanned for neck lesions other than those concerning the region of the SHC. The morphology of both SHCs was examined in the 3D-CT images and the following aspects were evaluated; 1. length, 2. thickness, 3. mediolateral angling (MLA), 4. anteroposterior angling (APA), and 5. bending of the SHC. Results Absence of the styloid process (n: 5), double proximal origin (n: 2), segmentation (n: 49), and complete ossification (n: 2) were found. The length of the SHC was 27.9 ± 11.3 mm, and 26.2 ± 11.1 mm on the right and left, respectively. The mean thickness of the SHC was 5 mm, and it showed positive correlation with length (P < 0.05). MLA was 73.2 ± 6.7 and 70.7° ± 8.0° for the right and left, respectively. APA was 64.6° ± 10.1° and 62.7° ± 10.2° for the right and left, respectively. There was a negative correlation between the right and left MLA (P = 0.001), and a positive correlation between the right and left APA (P = 0.001). Nine SHCs had bending of the lower end. Conclusion Three-dimensional CT gives detailed and reliable information about the SHC. We propose that the bending and thickness, which are new parameters, should be taken into consideration in the CT evaluation and classification of SHC variations.


    • 1 March 2003
      • Vol. 9  (1) , 113-4

    [Myositis ossificans circumscripta].

    by D Unlübay, M Kacar, Selma Uysal