Anne Negård
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anne Negård has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Arne Borthne
Department of Paediatric Radiology, Ullevål University Hospital, Oslo, Norway
3 shared publications- Erland Hermansen
Department of Research and Innovation, More and Romsdal Hopsital Trust, Alesund, Norway
3 shared publications - Jørn Aaen
AseHaugen 5, More and Romsdal Hopsital TrustDepartment of Orthopedics, Alesund, Norway
3 shared publications - Masoud Anvar
Unilabs Radiology, Oslo, Norway
3 shared publications Nils-Einar Klow
Ullevål University Hospital and Faculty of Medicine, University of Oslo
3 shared publications- Ansgar Espeland
Department of Radiology, Haukeland University Hospital, Bergen, Norway
2 shared publications
Latest Publications
- Open Access
- 8 December 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 50 (6) , 2401-2413
MRI of early rectal cancer; bisacodyl micro-enema increases submucosal width, reader confidence, and tumor conspicuity
Purpose: To investigate the influence of a micro-enema on diagnostic performance, submucosal width, reader confidence, and tumor conspicuity using MRI to stage early rectal cancers (ERC). Methods: In this single-center study, we consecutively included 50 participants with assumed ERC who all completed MRI with (MRin) and without (MRex) a micro-enema. The diagnostic performance was recorded for two experienced radiologists using histopathology as the gold standard. In addition, the width of the submucosa in the tumor-bearing wall, reader confidence for T-staging, and tumor conspicuity were assessed. Significance levels were calculated using McNemar’s test (diagnostic performance) and Wilcoxon’s signed-rank test (reader confidence, submucosal width, and conspicuity). Interreader agreement was assessed using kappa statistics. Results: Sensitivity/specificity were for Reader1 91%/87% for both MRex and MRin and for Reader2 74%/87% and 89%/87%, both readers p > 0.05. The micro-enema induced a significant widening of the submucosa, p < 0.001, with a mean increase of 2.2/2.8 mm measured by Reader1/Reader2. Reader confidence in T-staging and tumor conspicuity increased for both readers, p < 0.005. The proportion of tumors with both correct staging and high reader confidence increased from 58% (29/50) to 80% (40/50) (p = 0.04) for Reader1 and from 42% (21/50) to 72% (36/50) (p = 0.002) for Reader2. Interreader agreement increased from moderate (kappa 0.58) to good (kappa 0.68). Conclusion: The micro-enema significantly increased the submucosal width in the tumor-bearing wall, reader confidence, and tumor conspicuity and improved interreader agreement from moderate to good. Sensitivity and specificity in T-staging did not improve, but there was a significant increase in the proportion of tumors staged with both high confidence and correct T-stage. Graphical
- 8 December 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 50 (6) , 2401-2413
Open AccessMRI of early rectal cancer; bisacodyl micro-enema increases submucosal width, reader confidence, and tumor conspicuity
Purpose: To investigate the influence of a micro-enema on diagnostic performance, submucosal width, reader confidence, and tumor conspicuity using MRI to stage early rectal cancers (ERC). Methods: In this single-center study, we consecutively included 50 participants with assumed ERC who all completed MRI with (MRin) and without (MRex) a micro-enema. The diagnostic performance was recorded for two experienced radiologists using histopathology as the gold standard. In addition, the width of the submucosa in the tumor-bearing wall, reader confidence for T-staging, and tumor conspicuity were assessed. Significance levels were calculated using McNemar’s test (diagnostic performance) and Wilcoxon’s signed-rank test (reader confidence, submucosal width, and conspicuity). Interreader agreement was assessed using kappa statistics. Results: Sensitivity/specificity were for Reader1 91%/87% for both MRex and MRin and for Reader2 74%/87% and 89%/87%, both readers p > 0.05. The micro-enema induced a significant widening of the submucosa, p < 0.001, with a mean increase of 2.2/2.8 mm measured by Reader1/Reader2. Reader confidence in T-staging and tumor conspicuity increased for both readers, p < 0.005. The proportion of tumors with both correct staging and high reader confidence increased from 58% (29/50) to 80% (40/50) (p = 0.04) for Reader1 and from 42% (21/50) to 72% (36/50) (p = 0.002) for Reader2. Interreader agreement increased from moderate (kappa 0.58) to good (kappa 0.68). Conclusion: The micro-enema significantly increased the submucosal width in the tumor-bearing wall, reader confidence, and tumor conspicuity and improved interreader agreement from moderate to good. Sensitivity and specificity in T-staging did not improve, but there was a significant increase in the proportion of tumors staged with both high confidence and correct T-stage. Graphical
- Open Access
- 25 March 2024
- Published by Springer Nature in European Spine Journal
- Vol. 33 (5) , 1967-1978
Preoperative fatty infiltration of paraspinal muscles assessed by MRI is associated with less improvement of leg pain 2 years after surgery for lumbar spinal stenosis
Purpose: Fatty infiltration (FI) of the paraspinal muscles may associate with pain and surgical complications in patients with lumbar spinal stenosis (LSS). We evaluated the prognostic influence of MRI-assessed paraspinal muscles’ FI on pain or disability 2 years after surgery for LSS. Methods: A muscle fat index (MFI) was calculated (by dividing signal intensity of psoas to multifidus and erector spinae) on preoperative axial T2-weighted MRI of patients with LSS. Pain and disability 2 years after surgery were assessed using the Oswestry disability index, the Zurich claudication questionnaire and numeric rating scales for leg and back pain. Multivariate linear and logistic regression analyses (adjusted for preoperative outcome scores, age, body mass index, sex, smoking status, grade of spinal stenosis, disc degeneration and facet joint osteoarthritis) were used to assess the associations between MFI and patient-reported clinical outcomes. In the logistic regression models, odds ratios (OR) and 95% confidence intervals (CI) were calculated for associations between the MFI and ≥ 30% improvement of the outcomes (dichotomised into yes/no). Results: A total of 243 patients were evaluated (mean age 66.6 ± 8.5 years), 49% females (119). Preoperative MFI and postoperative leg pain were significantly associated, both with leg pain as continuous (coefficient − 3.20, 95% CI − 5.61, − 0.80) and dichotomised (OR 1.51, 95% CI 1.17, 1.95) scores. Associations between the MFI and the other outcome measures were not statistically significant. Conclusion: Preoperative FI of the paraspinal muscles on MRI showed statistically significant association with postoperative NRS leg pain but not with ODI or ZCQ.
- 25 March 2024
- Published by Springer Nature in European Spine Journal
- Vol. 33 (5) , 1967-1978
Open AccessPreoperative fatty infiltration of paraspinal muscles assessed by MRI is associated with less improvement of leg pain 2 years after surgery for lumbar spinal stenosis
Purpose: Fatty infiltration (FI) of the paraspinal muscles may associate with pain and surgical complications in patients with lumbar spinal stenosis (LSS). We evaluated the prognostic influence of MRI-assessed paraspinal muscles’ FI on pain or disability 2 years after surgery for LSS. Methods: A muscle fat index (MFI) was calculated (by dividing signal intensity of psoas to multifidus and erector spinae) on preoperative axial T2-weighted MRI of patients with LSS. Pain and disability 2 years after surgery were assessed using the Oswestry disability index, the Zurich claudication questionnaire and numeric rating scales for leg and back pain. Multivariate linear and logistic regression analyses (adjusted for preoperative outcome scores, age, body mass index, sex, smoking status, grade of spinal stenosis, disc degeneration and facet joint osteoarthritis) were used to assess the associations between MFI and patient-reported clinical outcomes. In the logistic regression models, odds ratios (OR) and 95% confidence intervals (CI) were calculated for associations between the MFI and ≥ 30% improvement of the outcomes (dichotomised into yes/no). Results: A total of 243 patients were evaluated (mean age 66.6 ± 8.5 years), 49% females (119). Preoperative MFI and postoperative leg pain were significantly associated, both with leg pain as continuous (coefficient − 3.20, 95% CI − 5.61, − 0.80) and dichotomised (OR 1.51, 95% CI 1.17, 1.95) scores. Associations between the MFI and the other outcome measures were not statistically significant. Conclusion: Preoperative FI of the paraspinal muscles on MRI showed statistically significant association with postoperative NRS leg pain but not with ODI or ZCQ.
- Open Access
- 12 October 2023
- Published by Elsevier in Data in Brief
- Vol. 51, 109672
Dataset on renal tumor diameter assessment by multiple observers in normal-dose and low-dose CT
- 12 October 2023
- Published by Elsevier in Data in Brief
- Vol. 51, 109672
Open AccessDataset on renal tumor diameter assessment by multiple observers in normal-dose and low-dose CT
- Open Access
- 15 January 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-9
Reliability of preoperative MRI findings in patients with lumbar spinal stenosis
Background: Magnetic Resonance Imaging (MRI) is an important tool in preoperative evaluation of patients with lumbar spinal stenosis (LSS). Reported reliability of various MRI findings in LSS varies from fair to excellent. There are inconsistencies in the evaluated parameters and the methodology of the studies. The purpose of this study was to evaluate the reliability of the preoperative MRI findings in patients with LSS between musculoskeletal radiologists and orthopaedic spine surgeons, using established evaluation methods and imaging data from a prospective trial. Methods: Consecutive lumbar MRI examinations of candidates for surgical treatment of LSS from the Norwegian Spinal Stenosis and Degenerative Spondylolisthesis (NORDSTEN) study were independently evaluated by two musculoskeletal radiologists and two orthopaedic spine surgeons. The observers had a range of experience between six and 13 years and rated five categorical parameters (foraminal and central canal stenosis, facet joint osteoarthritis, redundant nerve roots and intraspinal synovial cysts) and one continuous parameter (dural sac cross-sectional area). All parameters were re-rated after 6 weeks by all the observers. Inter- and intraobserver agreement was assessed by Gwet’s agreement coefficient (AC1) for categorical parameters and Intraclass Correlation Coefficient (ICC) for the dural sac cross-sectional area. Results: MRI examinations of 102 patients (mean age 66 ± 8 years, 53 men) were evaluated. The overall interobserver agreement was substantial or almost perfect for all categorical parameters (AC1 range 0.67 to 0.98), except for facet joint osteoarthritis, where the agreement was moderate (AC1 0.39). For the dural sac cross-sectional area, the overall interobserver agreement was good or excellent (ICC range 0.86 to 0.96). The intraobserver agreement was substantial or almost perfect/ excellent for all parameters (AC1 range 0.63 to 1.0 and ICC range 0.93 to 1.0). Conclusions: There is high inter- and intraobserver agreement between radiologists and spine surgeons for preoperative MRI findings of LSS. However, the interobserver agreement is not optimal for evaluation of facet joint osteoarthritis. Trial registration: www.ClinicalTrials.gov identifier: NCT02007083, registered December 2013.
- 15 January 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-9
Open AccessReliability of preoperative MRI findings in patients with lumbar spinal stenosis
Background: Magnetic Resonance Imaging (MRI) is an important tool in preoperative evaluation of patients with lumbar spinal stenosis (LSS). Reported reliability of various MRI findings in LSS varies from fair to excellent. There are inconsistencies in the evaluated parameters and the methodology of the studies. The purpose of this study was to evaluate the reliability of the preoperative MRI findings in patients with LSS between musculoskeletal radiologists and orthopaedic spine surgeons, using established evaluation methods and imaging data from a prospective trial. Methods: Consecutive lumbar MRI examinations of candidates for surgical treatment of LSS from the Norwegian Spinal Stenosis and Degenerative Spondylolisthesis (NORDSTEN) study were independently evaluated by two musculoskeletal radiologists and two orthopaedic spine surgeons. The observers had a range of experience between six and 13 years and rated five categorical parameters (foraminal and central canal stenosis, facet joint osteoarthritis, redundant nerve roots and intraspinal synovial cysts) and one continuous parameter (dural sac cross-sectional area). All parameters were re-rated after 6 weeks by all the observers. Inter- and intraobserver agreement was assessed by Gwet’s agreement coefficient (AC1) for categorical parameters and Intraclass Correlation Coefficient (ICC) for the dural sac cross-sectional area. Results: MRI examinations of 102 patients (mean age 66 ± 8 years, 53 men) were evaluated. The overall interobserver agreement was substantial or almost perfect for all categorical parameters (AC1 range 0.67 to 0.98), except for facet joint osteoarthritis, where the agreement was moderate (AC1 0.39). For the dural sac cross-sectional area, the overall interobserver agreement was good or excellent (ICC range 0.86 to 0.96). The intraobserver agreement was substantial or almost perfect/ excellent for all parameters (AC1 range 0.63 to 1.0 and ICC range 0.93 to 1.0). Conclusions: There is high inter- and intraobserver agreement between radiologists and spine surgeons for preoperative MRI findings of LSS. However, the interobserver agreement is not optimal for evaluation of facet joint osteoarthritis. Trial registration: www.ClinicalTrials.gov identifier: NCT02007083, registered December 2013.
- Open Access
- 22 June 2020
- Published by Morressier GmbH
Reliability of qualitative and quantitative imaging findings on X-ray and MRI in patients with lumbar spinal stenosis
Title: Reliability of qualitative and quantitative imaging findings on X-ray and MRI in patients with lumbar spinal stenosis Purpose: To evaluate the inter- and intraobserver reliability of imaging findings and measurements of lumbar spinal stenosis on X-ray and MRI using experienced musculoskeletal radiologists and spinal surgeons as observers. Methods and Materials: 108
- 22 June 2020
- Published by Morressier GmbH
Open AccessReliability of qualitative and quantitative imaging findings on X-ray and MRI in patients with lumbar spinal stenosis
Title: Reliability of qualitative and quantitative imaging findings on X-ray and MRI in patients with lumbar spinal stenosis Purpose: To evaluate the inter- and intraobserver reliability of imaging findings and measurements of lumbar spinal stenosis on X-ray and MRI using experienced musculoskeletal radiologists and spinal surgeons as observers. Methods and Materials: 108
- 20 March 2009
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 55 (1) , 14-20
Feasibility of MRI in Experimentally Induced Inflammatory Small Bowel Disease: A Pilot Study in a Porcine Model
The purpose of this study was to compare the macroscopic and microscopic findings of experimentally induced inflammatory lesions in jejunum and ileum with magnetic resonance imaging (MRI) findings. Inflammatory small bowel lesions were experimentally induced in six pigs. Bowel segments in jejunum and ileum were isolated, and a solution with trinitrobenzenesulfonic acid and ethanol (TNBS-EtOH) was installed. MRI of the small bowel was performed 7 days after surgery. Before the MRI examination, a 6% mannitol solution was installed through a nasogastric tube. The MRI protocol consisted of single-shot turbo spin echo T2 sequences, steady state free precession (BFFE) sequences, and a 3D T1 gradient echo sequence with fat saturation and intravenous contrast. The following image findings were evaluated: increased bowel wall thickness (BWT), increased bowel wall enhancement (BWE), and bowel stenosis. After the MRI examination, the animals were sacrificed. The small bowel was removed and examined macroscopically and microscopically. Inflammatory lesions developed in jejunum and ileum in all animals. The lesions were visible macroscopically and microscopically. The microscopic findings consisted of variable degrees of inflammation, ulcer formation, and fibrosis. In jejunum the inflammatory lesions were not diagnosed with MRI, except in one pig with a bowel necrosis probably caused by an intramural injection or leakage of the TNBS-EtOH solution. In ileum the bowel wall thickness was increased and the inflammatory lesions were diagnosed with MRI. In conclusion, the inflammatory lesions were visible macroscopically and microscopically. Lesions in ileum had increased BWT and were possible to image with MRI. Lesions in jejunum had normal BWT and were not diagnosed with MRI, except in one pig with increased BWT probably caused by complications to the installation of TNBS-EtOH.
- 20 March 2009
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 55 (1) , 14-20
Feasibility of MRI in Experimentally Induced Inflammatory Small Bowel Disease: A Pilot Study in a Porcine Model
The purpose of this study was to compare the macroscopic and microscopic findings of experimentally induced inflammatory lesions in jejunum and ileum with magnetic resonance imaging (MRI) findings. Inflammatory small bowel lesions were experimentally induced in six pigs. Bowel segments in jejunum and ileum were isolated, and a solution with trinitrobenzenesulfonic acid and ethanol (TNBS-EtOH) was installed. MRI of the small bowel was performed 7 days after surgery. Before the MRI examination, a 6% mannitol solution was installed through a nasogastric tube. The MRI protocol consisted of single-shot turbo spin echo T2 sequences, steady state free precession (BFFE) sequences, and a 3D T1 gradient echo sequence with fat saturation and intravenous contrast. The following image findings were evaluated: increased bowel wall thickness (BWT), increased bowel wall enhancement (BWE), and bowel stenosis. After the MRI examination, the animals were sacrificed. The small bowel was removed and examined macroscopically and microscopically. Inflammatory lesions developed in jejunum and ileum in all animals. The lesions were visible macroscopically and microscopically. The microscopic findings consisted of variable degrees of inflammation, ulcer formation, and fibrosis. In jejunum the inflammatory lesions were not diagnosed with MRI, except in one pig with a bowel necrosis probably caused by an intramural injection or leakage of the TNBS-EtOH solution. In ileum the bowel wall thickness was increased and the inflammatory lesions were diagnosed with MRI. In conclusion, the inflammatory lesions were visible macroscopically and microscopically. Lesions in ileum had increased BWT and were possible to image with MRI. Lesions in jejunum had normal BWT and were not diagnosed with MRI, except in one pig with increased BWT probably caused by complications to the installation of TNBS-EtOH.
- 1 January 2008
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 43 (1) , 44-51
MRI of the small bowel with oral contrast or nasojejunal intubation in Crohn's disease: Randomized comparison of patient acceptance
Objective. Magnetic resonance imaging of the small bowel with an oral contrast (MRI per os) is believed to generate fewer adverse symptoms compared with installation of the contrast in a nasojejunal catheter (MRE). However, there is very little evidence to support this assumption. The aim of this study was to evaluate the compliance of patients examined with both of these MRI methods. Material and methods. Patients with suspected or known Crohn's disease referred for MRI of the small bowel underwent both MRI per os and MRE within 7 days. A questionnaire was answered immediately and 24 h after the procedure. Adverse symptoms were graded on a visual analogue scale (VAS). Responses were compared with paired and independent sample t-tests and signed-rank tests. Correlation of each symptom to the overall discomfort was evaluated with Spearman's correlation coefficient. Results. Thirty-eight patients (18 F, 20 M) were included in the analysis. Abdominal pain and discomfort were lower with MRI per os than with MRE (mean VAS pain score immediately after: 10 mm and 33 mm, respectively, ppr=0.56 for both, pn=36) than MRE (n=22, p=0.001). Conclusion. Patients preferred and experienced less abdominal pain and discomfort with MRI per os than with MRE.
- 1 January 2008
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 43 (1) , 44-51
MRI of the small bowel with oral contrast or nasojejunal intubation in Crohn's disease: Randomized comparison of patient acceptance
Objective. Magnetic resonance imaging of the small bowel with an oral contrast (MRI per os) is believed to generate fewer adverse symptoms compared with installation of the contrast in a nasojejunal catheter (MRE). However, there is very little evidence to support this assumption. The aim of this study was to evaluate the compliance of patients examined with both of these MRI methods. Material and methods. Patients with suspected or known Crohn's disease referred for MRI of the small bowel underwent both MRI per os and MRE within 7 days. A questionnaire was answered immediately and 24 h after the procedure. Adverse symptoms were graded on a visual analogue scale (VAS). Responses were compared with paired and independent sample t-tests and signed-rank tests. Correlation of each symptom to the overall discomfort was evaluated with Spearman's correlation coefficient. Results. Thirty-eight patients (18 F, 20 M) were included in the analysis. Abdominal pain and discomfort were lower with MRI per os than with MRE (mean VAS pain score immediately after: 10 mm and 33 mm, respectively, ppr=0.56 for both, pn=36) than MRE (n=22, p=0.001). Conclusion. Patients preferred and experienced less abdominal pain and discomfort with MRI per os than with MRE.
- 5 May 2007
- Published by Springer Nature in European Radiology
- Vol. 17 (9) , 2294-2301
A prospective randomized comparison between two MRI studies of the small bowel in Crohn’s disease, the oral contrast method and MR enteroclysis
The aim was to compare bowel distension and diagnostic properties of magnetic resonance imaging of the small bowel with oral contrast (MRI per OS) with magnetic resonance enteroclysis (MRE). Forty patients with suspected Crohn’s disease (CD) were examined with both MRI methods. MRI per OS was performed with a 6% mannitol solution and MRE with nasojejunal intubation and a polyethylenglycol solution. MRI protocol consisted of balanced fast field echo (B-FFE), T2 and T1 sequences with and without gadolinium. Two experienced radiologists individually evaluated bowel distension and pathological findings including wall thickness (BWT), contrast enhancement (BWE), ulcer (BWU), stenosis (BWS) and edema (EDM). The diameter of the small bowel was smaller with MRI per OS than with MRE (difference jejunum: 0.55 cm, p < 0.001; ileum: 0.35 cm, p < 0.001, terminal ileum: 0.09 cm, p = 0.08). However, CD was diagnosed with high diagnostic accuracy (sensitivity, specificity, positive and negative predictive values: MRI per OS 88%, 89%, 89%, 89%; MRE 88%, 84%, 82%, 89%) and inter-observer agreement (MRI per OS k = 0.95; MRE k = 1). In conclusion, bowel distension was inferior in MRI per OS compared to MRE. However, both methods diagnosed CD with a high diagnostic accuracy and reproducibility.
- 5 May 2007
- Published by Springer Nature in European Radiology
- Vol. 17 (9) , 2294-2301
A prospective randomized comparison between two MRI studies of the small bowel in Crohn’s disease, the oral contrast method and MR enteroclysis
The aim was to compare bowel distension and diagnostic properties of magnetic resonance imaging of the small bowel with oral contrast (MRI per OS) with magnetic resonance enteroclysis (MRE). Forty patients with suspected Crohn’s disease (CD) were examined with both MRI methods. MRI per OS was performed with a 6% mannitol solution and MRE with nasojejunal intubation and a polyethylenglycol solution. MRI protocol consisted of balanced fast field echo (B-FFE), T2 and T1 sequences with and without gadolinium. Two experienced radiologists individually evaluated bowel distension and pathological findings including wall thickness (BWT), contrast enhancement (BWE), ulcer (BWU), stenosis (BWS) and edema (EDM). The diameter of the small bowel was smaller with MRI per OS than with MRE (difference jejunum: 0.55 cm, p < 0.001; ileum: 0.35 cm, p < 0.001, terminal ileum: 0.09 cm, p = 0.08). However, CD was diagnosed with high diagnostic accuracy (sensitivity, specificity, positive and negative predictive values: MRI per OS 88%, 89%, 89%, 89%; MRE 88%, 84%, 82%, 89%) and inter-observer agreement (MRI per OS k = 0.95; MRE k = 1). In conclusion, bowel distension was inferior in MRI per OS compared to MRE. However, both methods diagnosed CD with a high diagnostic accuracy and reproducibility.
- 17 November 2005
- Vol. 125 (22) , 3094-7
[Magnetic resonance imaging of the small bowel].
Conventional small bowel enteroclysis is considered the principal radiological method to investigate the small bowel. However, the method has important limitations and magnetic resonance imaging (MRI) has been introduced as an alternative. This review is based on the literature and our clinical experience. There are two main methods for MRI examination of the small bowel. One method uses a tube placed in the jejunum prior to the MRI examination and the other uses simple oral administration of contrast media. These methods are both shown to be as good as conventional X-ray examinations of the small bowel when used for follow up of patients with Crohn's disease. However, the resolution in MRI of the small bowel is insufficient to depict small superficial lesions. MRI should therefore be used as the preferred radiological method for follow up of patients with known Crohn's disease. When the primary diagnosis is not known, MRI should be used only as a supplement to more extensive investigations.
- 17 November 2005
- Vol. 125 (22) , 3094-7
[Magnetic resonance imaging of the small bowel].
Conventional small bowel enteroclysis is considered the principal radiological method to investigate the small bowel. However, the method has important limitations and magnetic resonance imaging (MRI) has been introduced as an alternative. This review is based on the literature and our clinical experience. There are two main methods for MRI examination of the small bowel. One method uses a tube placed in the jejunum prior to the MRI examination and the other uses simple oral administration of contrast media. These methods are both shown to be as good as conventional X-ray examinations of the small bowel when used for follow up of patients with Crohn's disease. However, the resolution in MRI of the small bowel is insufficient to depict small superficial lesions. MRI should therefore be used as the preferred radiological method for follow up of patients with known Crohn's disease. When the primary diagnosis is not known, MRI should be used only as a supplement to more extensive investigations.