Alexandre-Amir Aalam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Alexandre-Amir Aalam has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Hessam Nowzari
5 shared publicationsAlina Krivitsky
1 shared publication- David Dds Zelig
Department of Oral and Maxillofacial Surgery, North Jersey Oral and Maxillofacial Surgery, Teaneck, NJ
1 shared publication - Gregori M. Kurtzman
Private practice, Silver Spring, Md
1 shared publication Mamaly Reshad
1 shared publication- Simon Dds Oh
Private practice – Oral Surgery, Fair Hills, Pennsylvania
1 shared publication
Latest Publications
- Open Access
- 11 April 2023
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 85 (5) , 1959-1965
Case report: utilization of Z-Point fixture “Trans-nasal” implants
Background: Severe bone loss in the anterior maxilla poses challenges to implant placement, especially when treating the entire arch. Utilization of zygomatic implants may not allow positioning of the implant platform anterior enough to properly support the full arch prosthesis, leaving an anterior cantilever in some clinical cases. Importance: Placement of implants into the trans-nasal bone between the pneumatized maxillary sinus and nasal fossa allows utilization of an extralong implant in this residual bone to augment zygomatic implants placed distal to this for better support of a full arch prosthesis. Case presentation: A typical case is presented with insufficient alveolar height for traditional implant placement in the anterior maxilla following extraction of the dentition related to bone loss resulting from periodontal disease. Review of the anatomy and technique for placement of implants into the Z-point area for trans-nasal implants. Clinical discussion: This article discusses the utilization of trans-nasal implants into the Z-point and the technique for placement in this residual bone with a case example. Conclusions: The Z-point implant aids in the elimination of the anterior cantilever that may be present due to the most anterior the platform for the zygomatic implant can be placed. Trans-nasal implants should be considered as part of the treatment plan in severely resorbed maxillary arches to allow better implant to spread and load management during functioning.
- 11 April 2023
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 85 (5) , 1959-1965
Open AccessCase report: utilization of Z-Point fixture “Trans-nasal” implants
Background: Severe bone loss in the anterior maxilla poses challenges to implant placement, especially when treating the entire arch. Utilization of zygomatic implants may not allow positioning of the implant platform anterior enough to properly support the full arch prosthesis, leaving an anterior cantilever in some clinical cases. Importance: Placement of implants into the trans-nasal bone between the pneumatized maxillary sinus and nasal fossa allows utilization of an extralong implant in this residual bone to augment zygomatic implants placed distal to this for better support of a full arch prosthesis. Case presentation: A typical case is presented with insufficient alveolar height for traditional implant placement in the anterior maxilla following extraction of the dentition related to bone loss resulting from periodontal disease. Review of the anatomy and technique for placement of implants into the Z-point area for trans-nasal implants. Clinical discussion: This article discusses the utilization of trans-nasal implants into the Z-point and the technique for placement in this residual bone with a case example. Conclusions: The Z-point implant aids in the elimination of the anterior cantilever that may be present due to the most anterior the platform for the zygomatic implant can be placed. Trans-nasal implants should be considered as part of the treatment plan in severely resorbed maxillary arches to allow better implant to spread and load management during functioning.
- 1 May 2007
- Vol. 28 (5) , 274
Mandibular cortical bone graft part 2: surgical technique, applications, and morbidity.
The mandibular cortical grafts, including the ramus graft, are reliable donor sites for the reconstruction of the alveolar ridge deformities before dental implant placement. The highest concentrations of promoter proteins (e.g., bone morphogenetic proteins) are found in the mandibular cortical grafts. Part 1 of this article (April issue) reviewed the anatomical considerations of mandibular cortical grafts, the associated healing process, and the factors influencing graft incorporation. This article describes mandibular ramus graft before implant placement including the surgical technique, applications, and morbidity
- 1 May 2007
- Vol. 28 (5) , 274
Mandibular cortical bone graft part 2: surgical technique, applications, and morbidity.
The mandibular cortical grafts, including the ramus graft, are reliable donor sites for the reconstruction of the alveolar ridge deformities before dental implant placement. The highest concentrations of promoter proteins (e.g., bone morphogenetic proteins) are found in the mandibular cortical grafts. Part 1 of this article (April issue) reviewed the anatomical considerations of mandibular cortical grafts, the associated healing process, and the factors influencing graft incorporation. This article describes mandibular ramus graft before implant placement including the surgical technique, applications, and morbidity
- 1 April 2007
- Vol. 28 (4) , 206
Mandibular cortical bone grafts part 1: anatomy, healing process, and influencing factors.
Mandibular cortical grafts are the gold standard in the restoration of intraoral osseous volume. Mandibular cortical grafts do not produce immune reactions and are incorporated by osteoclastic resorption with a short healing period when compared with other methods of osseous repair. Intraoral donor sites include the mandibular ramus, angle of the mandible, mandibular symphysis, and mandibular exostoses. The mandibular ramus provides primarily a dense cortical graft. Other advantages of a mandibular ramus transplant are minimal resorption, maintenance of osseous density, intraoral access, and proximity to the recipient site. This article is Part 1 of a 2-part presentation. It reviews anatomical considerations of mandibular cortical grafts, the associated healing process, and the factors influencing graft incorporation. Part 2 will discuss surgical technique, applications, and morbidity.
- 1 April 2007
- Vol. 28 (4) , 206
Mandibular cortical bone grafts part 1: anatomy, healing process, and influencing factors.
Mandibular cortical grafts are the gold standard in the restoration of intraoral osseous volume. Mandibular cortical grafts do not produce immune reactions and are incorporated by osteoclastic resorption with a short healing period when compared with other methods of osseous repair. Intraoral donor sites include the mandibular ramus, angle of the mandible, mandibular symphysis, and mandibular exostoses. The mandibular ramus provides primarily a dense cortical graft. Other advantages of a mandibular ramus transplant are minimal resorption, maintenance of osseous density, intraoral access, and proximity to the recipient site. This article is Part 1 of a 2-part presentation. It reviews anatomical considerations of mandibular cortical grafts, the associated healing process, and the factors influencing graft incorporation. Part 2 will discuss surgical technique, applications, and morbidity.
- 9 November 2005
- Vol. 20 (5) , 793-8
Clinical evaluation of dental implants with surfaces roughened by anodic oxidation, dual acid-etched implants, and machined implants.
The purpose of this study was the clinical and radiographic comparison of dental implants with surfaces roughened by anodic oxidation (TiUnite), dual acid-etched implants (Osseotite), and machined implants. Seventy-four patients (mean age, 52.8 +/- 14.2 years; range, 23 to 80 years; 41 men and 33 women) received 198 dental implants-58 TiUnite implants (25 patients), 52 Osseotite implants (27 patients), and 88 machined implants (22 patients). Clinical measurements and radiographs were evaluated at the time of surgery, at the restorative phase, and 2 years postloading. To account for statistical correlation among multiple implants in the same subject, a "per patient" mode of analysis was conducted. A 1-way analysis of variance of bone loss was conducted by type of implant as well by area of the mouth. In addition, differences in mean bone loss were tested for bone density category, gender, and smoking status using Student t tests. Eighteen TiUnite implants (31.0%) were placed in the maxilla and 40 (69.0%) in the mandible. The Osseotite group included 29 maxillary implants (55.8%) and 23 mandibular implants (44.2%). The machined group included 49 maxillary implants (55.7%) and 39 mandibular implants (44.3%). All 198 implants were considered radiographically and clinically successful. No mobility, signs of infection, or inflammation were detected. Implant size, location, bone quality, gender, age, and smoking did not influence the comparative clinical outcomes of the 3 groups (P > .05). A trend toward greater coronal bone loss in the TiUnite group was detected. Within the limitations of the present study, TiUnite, Osseotite, and machined dental implants had similar short-term clinical outcomes. No statistically significant differences in bone loss could be detected among implant groups or among the different regions of the oral cavity. The present data underlined the significance of surgical and prosthetic treatment planning.
- 9 November 2005
- Vol. 20 (5) , 793-8
Clinical evaluation of dental implants with surfaces roughened by anodic oxidation, dual acid-etched implants, and machined implants.
The purpose of this study was the clinical and radiographic comparison of dental implants with surfaces roughened by anodic oxidation (TiUnite), dual acid-etched implants (Osseotite), and machined implants. Seventy-four patients (mean age, 52.8 +/- 14.2 years; range, 23 to 80 years; 41 men and 33 women) received 198 dental implants-58 TiUnite implants (25 patients), 52 Osseotite implants (27 patients), and 88 machined implants (22 patients). Clinical measurements and radiographs were evaluated at the time of surgery, at the restorative phase, and 2 years postloading. To account for statistical correlation among multiple implants in the same subject, a "per patient" mode of analysis was conducted. A 1-way analysis of variance of bone loss was conducted by type of implant as well by area of the mouth. In addition, differences in mean bone loss were tested for bone density category, gender, and smoking status using Student t tests. Eighteen TiUnite implants (31.0%) were placed in the maxilla and 40 (69.0%) in the mandible. The Osseotite group included 29 maxillary implants (55.8%) and 23 mandibular implants (44.2%). The machined group included 49 maxillary implants (55.7%) and 39 mandibular implants (44.3%). All 198 implants were considered radiographically and clinically successful. No mobility, signs of infection, or inflammation were detected. Implant size, location, bone quality, gender, age, and smoking did not influence the comparative clinical outcomes of the 3 groups (P > .05). A trend toward greater coronal bone loss in the TiUnite group was detected. Within the limitations of the present study, TiUnite, Osseotite, and machined dental implants had similar short-term clinical outcomes. No statistically significant differences in bone loss could be detected among implant groups or among the different regions of the oral cavity. The present data underlined the significance of surgical and prosthetic treatment planning.
- 25 June 2005
- Vol. 20 (3) , 462-5
Surgical template stabilization with transitional implants in the treatment of the edentulous mandible: a technical note.
Proper placement and orientation of dental implants is a requirement for the optimum function and esthetics of the definitive restoration. Surgical template stability during the surgical phase is a key element in the success of proper implant placement. Therefore, any clinical tool that enhances the precision of reproduction is of value. This article describes a simple, noninvasive, cost-effective technique for surgical template stabilization utilizing 2 transitional implants placed the same day as the definitive implants.
- 25 June 2005
- Vol. 20 (3) , 462-5
Surgical template stabilization with transitional implants in the treatment of the edentulous mandible: a technical note.
Proper placement and orientation of dental implants is a requirement for the optimum function and esthetics of the definitive restoration. Surgical template stability during the surgical phase is a key element in the success of proper implant placement. Therefore, any clinical tool that enhances the precision of reproduction is of value. This article describes a simple, noninvasive, cost-effective technique for surgical template stabilization utilizing 2 transitional implants placed the same day as the definitive implants.
- 1 January 2005
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 7 (1) , 10-16
Functional Restoration of Implants on the Day of Surgical Placement in the Fully Edentulous Mandible: A Case Series
Purpose: The purpose of this article is to report the clinical experience and outcome of a study of the functional rehabilitation of 16 completely edentulous mandibles with immediately loaded cross‐arch screw‐retained hybrid prostheses at the University of Southern California. Materials and Methods: After signing informed consent forms 16 patients (9 male, 7 female) aged 47 to 84 years (mean age, 62.6 ± 11.6 years) received 90 Brånemark System® Mk III dental implants (Nobel Biocare USA, Yorba Linda, CA, USA). Stability and radiographs of the dental implants were evaluated at the time of surgery, at 3 months, at 1 year, and at 3 years post loading. Results: Three implants failed to meet the criteria of success, bringing the cumulative success rate to 96.6%, with a 100% prosthetic success rate at 3 years. Thirty‐nine (43.3%) of the dental implants placed were 15 mm in length. Seventy‐seven (85.5%) of the dental implants were placed in high‐density bone. At 3 years post loading, the average bone loss was −1.2 ± 0.1 mm. Conclusion: Within the limitations of this study, restoration of implants by unreinforced hybrid prostheses at the time of placement provided satisfactory results. The outcome was stable at 3 years post restoration. Mandibular rehabilitation by functional loading of the implants on the day of the insertion requires the comprehension and proper application of surgical and restorative principles.
- 1 January 2005
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 7 (1) , 10-16
Functional Restoration of Implants on the Day of Surgical Placement in the Fully Edentulous Mandible: A Case Series
Purpose: The purpose of this article is to report the clinical experience and outcome of a study of the functional rehabilitation of 16 completely edentulous mandibles with immediately loaded cross‐arch screw‐retained hybrid prostheses at the University of Southern California. Materials and Methods: After signing informed consent forms 16 patients (9 male, 7 female) aged 47 to 84 years (mean age, 62.6 ± 11.6 years) received 90 Brånemark System® Mk III dental implants (Nobel Biocare USA, Yorba Linda, CA, USA). Stability and radiographs of the dental implants were evaluated at the time of surgery, at 3 months, at 1 year, and at 3 years post loading. Results: Three implants failed to meet the criteria of success, bringing the cumulative success rate to 96.6%, with a 100% prosthetic success rate at 3 years. Thirty‐nine (43.3%) of the dental implants placed were 15 mm in length. Seventy‐seven (85.5%) of the dental implants were placed in high‐density bone. At 3 years post loading, the average bone loss was −1.2 ± 0.1 mm. Conclusion: Within the limitations of this study, restoration of implants by unreinforced hybrid prostheses at the time of placement provided satisfactory results. The outcome was stable at 3 years post restoration. Mandibular rehabilitation by functional loading of the implants on the day of the insertion requires the comprehension and proper application of surgical and restorative principles.