Charles J. Taunt
Research Subjects
Charles J. Taunt has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Brett G. Brazier
College of Osteopathic Medicine
1 shared publication - Jonathan J. Vaux
Gundarson Building Orthopedics, The Everett Clinic, Everett, Washington
1 shared publication Kanwaldeep S. Sidhu
1 shared publication- Michael J. Blackmer
McLaren Orthopedic Hospital, 2727 S Pennsylvania Ave, Lansing, MI, 48910, USA
1 shared publication - Robert L. Zondervan
College of Osteopathic Medicine, Michigan State University, East Lansing, Michigan, USA
1 shared publication Shane A. Andrew
1 shared publication
Latest Publications
- Open Access
- 17 June 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-10
Improved outcomes in patients with positive metal sensitivity following revision total knee arthroplasty
Metal sensitivity as a cause for painful joint replacement has become increasingly prevalent; however, there is a lack of reported clinical outcome data from total knee arthroplasty patients with metal allergies. The purpose of this study was to determine whether patients presenting with a painful total knee arthroplasty with a positive metal sensitivity have improved outcomes following revision to a hypoallergenic implant. A retrospective review was conducted for patients that underwent a revision total knee arthroplasty after metal sensitivity testing over a 3-year period from January 1, 2015, to December 31, 2017. Based on the results of sensitivity testing, patients underwent revision total knee arthroplasty to a hypoallergenic component or a standard component. Following revision, patients returned to the clinic at an interval of 6 weeks, 5 months, and 12 months for functional, pain, and satisfaction assessment. Outcomes were compared within and between sensitivity groups. Of the included patients, 78.3% (39/46) were positive for metal sensitivity. The most common metal sensitivity was to nickel (79.5%, 32/39). Both non-reactive and reactive patients significantly improved in range of motion after revision arthroplasty. The reactive group saw a 37.8% decrease in pain at 6 weeks post-revision (p < 0.001) Whereas, the non-reactive group only saw a moderate, non-significant improvement in pain reduction at 6 weeks post-revision (27.0%; p = 0.29). Frequency of pain experienced did not vary significantly between groups. Maximum metal lymphocyte transformation test (LTT) sensitivity score did not correlate with pain level at the time of revision (R2 = 0.02, p = 0.38) or percent improvement after revision (R2 = 0.001, p = 0.81). Overall, all patients reported being very satisfied after revision total knee arthroplasty; there was no difference between positive and negative sensitivity groups (W = 62, p = 0.89). Patients presenting with a painful knee arthroplasty and positive metal LTT have improved pain scores, walking function, and range of motion following revision to a hypoallergenic component. This study also provides a treatment algorithm for patients presenting with a painful knee replacement, in order to provide effective and timely diagnosis and management.
- 17 June 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-10
Open AccessImproved outcomes in patients with positive metal sensitivity following revision total knee arthroplasty
Metal sensitivity as a cause for painful joint replacement has become increasingly prevalent; however, there is a lack of reported clinical outcome data from total knee arthroplasty patients with metal allergies. The purpose of this study was to determine whether patients presenting with a painful total knee arthroplasty with a positive metal sensitivity have improved outcomes following revision to a hypoallergenic implant. A retrospective review was conducted for patients that underwent a revision total knee arthroplasty after metal sensitivity testing over a 3-year period from January 1, 2015, to December 31, 2017. Based on the results of sensitivity testing, patients underwent revision total knee arthroplasty to a hypoallergenic component or a standard component. Following revision, patients returned to the clinic at an interval of 6 weeks, 5 months, and 12 months for functional, pain, and satisfaction assessment. Outcomes were compared within and between sensitivity groups. Of the included patients, 78.3% (39/46) were positive for metal sensitivity. The most common metal sensitivity was to nickel (79.5%, 32/39). Both non-reactive and reactive patients significantly improved in range of motion after revision arthroplasty. The reactive group saw a 37.8% decrease in pain at 6 weeks post-revision (p < 0.001) Whereas, the non-reactive group only saw a moderate, non-significant improvement in pain reduction at 6 weeks post-revision (27.0%; p = 0.29). Frequency of pain experienced did not vary significantly between groups. Maximum metal lymphocyte transformation test (LTT) sensitivity score did not correlate with pain level at the time of revision (R2 = 0.02, p = 0.38) or percent improvement after revision (R2 = 0.001, p = 0.81). Overall, all patients reported being very satisfied after revision total knee arthroplasty; there was no difference between positive and negative sensitivity groups (W = 62, p = 0.89). Patients presenting with a painful knee arthroplasty and positive metal LTT have improved pain scores, walking function, and range of motion following revision to a hypoallergenic component. This study also provides a treatment algorithm for patients presenting with a painful knee replacement, in order to provide effective and timely diagnosis and management.
- 1 September 2005
- Published by Wolters Kluwer Health in Spine
- Vol. 30 (17) , 1970-1972
Somatosensory Evoked Potential Monitoring During Anterior Cervical Discectomy and Fusion
A retrospective, multicenter clinical review was conducted. To examine our experience using somatosensory evoked potential (SSEP) monitoring during anterior cervical discectomy and fusion (ACDF) to determine if monitoring of the spinal cord with SSEPs was helpful in identifying reversible causes of neurologic impairment while performing the procedure. Recent studies have strongly supported the use of SSEP monitoring during complicated and upper-cervical spine surgery. The complete medical records of 163 patients who underwent ACDF, and who were monitored with SSEPs during the procedure between 1995 and 2002 were retrospectively reviewed. A single observer who was uninvolved with patient care abstracted these medical records. Demographic data, length of symptoms, workers' compensation status, primary diagnosis, preoperative neurologic status, number of levels fused, bone graft type, implants used, SSEP findings, postoperative neurologic status, complications, and recovery from complications were recorded. Final neurologic status was determined through phone contact with patients or outpatient charts of patients who could not be contacted personally. There were 3 false positive (1.8%) intraoperative SSEP findings in which SSEP changes intraoperatively did not reflect a neurologic deterioration after surgery. There was 1 false negative (0.6%) in which a new neurologic deficit occurred after surgery, despite no change in SSEP amplitudes during the operation. There were 2 true negatives (1.2%) in which SSEP monitoring showed a preexisting neurologic deficit, which did not change during the operation. In no instance were positive SSEP findings clinically useful in alerting the surgeon to potential intraoperative complications. Intraoperative SSEP monitoring is not helpful to the surgeon when performing routine ACDF. Additionally, ACDF is a safe procedure with a low rate of neurologic complications.
- 1 September 2005
- Published by Wolters Kluwer Health in Spine
- Vol. 30 (17) , 1970-1972
Somatosensory Evoked Potential Monitoring During Anterior Cervical Discectomy and Fusion
A retrospective, multicenter clinical review was conducted. To examine our experience using somatosensory evoked potential (SSEP) monitoring during anterior cervical discectomy and fusion (ACDF) to determine if monitoring of the spinal cord with SSEPs was helpful in identifying reversible causes of neurologic impairment while performing the procedure. Recent studies have strongly supported the use of SSEP monitoring during complicated and upper-cervical spine surgery. The complete medical records of 163 patients who underwent ACDF, and who were monitored with SSEPs during the procedure between 1995 and 2002 were retrospectively reviewed. A single observer who was uninvolved with patient care abstracted these medical records. Demographic data, length of symptoms, workers' compensation status, primary diagnosis, preoperative neurologic status, number of levels fused, bone graft type, implants used, SSEP findings, postoperative neurologic status, complications, and recovery from complications were recorded. Final neurologic status was determined through phone contact with patients or outpatient charts of patients who could not be contacted personally. There were 3 false positive (1.8%) intraoperative SSEP findings in which SSEP changes intraoperatively did not reflect a neurologic deterioration after surgery. There was 1 false negative (0.6%) in which a new neurologic deficit occurred after surgery, despite no change in SSEP amplitudes during the operation. There were 2 true negatives (1.2%) in which SSEP monitoring showed a preexisting neurologic deficit, which did not change during the operation. In no instance were positive SSEP findings clinically useful in alerting the surgeon to potential intraoperative complications. Intraoperative SSEP monitoring is not helpful to the surgeon when performing routine ACDF. Additionally, ACDF is a safe procedure with a low rate of neurologic complications.