D. Duane Baldwin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
D. Duane Baldwin has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Arputharaj Kore
Transplantation Institute Loma Linda University Medical Center Loma Linda CA USA
1 shared publicationArvand Elihu
Transplantation Institute Loma Linda University Medical Center Loma Linda CA USA
1 shared publicationCraig H. Robson
1 shared publicationDrew Cutler
Department of Pediatrics Loma Linda University Medical Center Loma Linda CA USA
1 shared publicationJaysson Brooks
Department of Orthopaedic Surgery Johns Hopkins University Baltimore MD USA
1 shared publicationKenneth A. Berger
1 shared publication
Latest Publications
- 16 April 2013
- Published by Wiley in Pediatric Transplantation
- Vol. 17 (4) , 374-379
Comparison of outcomes of hand‐assisted laparoscopic to open donor nephrectomy for pediatric recipients
The purpose of this study is to compare the outcome of pediatric recipients of kidneys procured using a hand-assisted laparoscopic (HALDN group) to an open technique (ODN group). Twenty-eight patients ≤18 yr old (HALDN group) were compared with 17 patients (ODN group). The serum creatinine for HALDN and ODN groups at discharge were 0.93 ± 0.48 and 0.94 ± 0.54 mg/dL (p = 0.917), respectively. The serum creatinine for HALDN and ODN groups at six and 12 months was 1.01 ± 0.44 and 1.11 ± 0.55, and 1.04 ± 0.52 and 1.14 ± 0.46 mg/dL (p = 0.516, p = 0.554), respectively. The eGFR for HALDN and ODN groups at discharge was 108.66 ± 37.23 and 106.1 ± 50.55 mL/min/1.73 m(2) (p = 0.845), respectively. The eGFR for HALDN and ODN groups at six and 12 months was 97.77 ± 28.25 and 81.73 ± 27.46, and 94.56 ± 28.3 and 85.74 ± 30.1 mL/min/1.73 m2 (p = 0.085, p = 0.344), respectively. The patient and graft survival for both groups were 100% at 12 months post-transplant. In conclusion, the short-term outcome of recipients of kidneys procured via HALDN is comparable to that of kidneys procured via ODN in pediatric patients.
- 16 April 2013
- Published by Wiley in Pediatric Transplantation
- Vol. 17 (4) , 374-379
Comparison of outcomes of hand‐assisted laparoscopic to open donor nephrectomy for pediatric recipients
The purpose of this study is to compare the outcome of pediatric recipients of kidneys procured using a hand-assisted laparoscopic (HALDN group) to an open technique (ODN group). Twenty-eight patients ≤18 yr old (HALDN group) were compared with 17 patients (ODN group). The serum creatinine for HALDN and ODN groups at discharge were 0.93 ± 0.48 and 0.94 ± 0.54 mg/dL (p = 0.917), respectively. The serum creatinine for HALDN and ODN groups at six and 12 months was 1.01 ± 0.44 and 1.11 ± 0.55, and 1.04 ± 0.52 and 1.14 ± 0.46 mg/dL (p = 0.516, p = 0.554), respectively. The eGFR for HALDN and ODN groups at discharge was 108.66 ± 37.23 and 106.1 ± 50.55 mL/min/1.73 m(2) (p = 0.845), respectively. The eGFR for HALDN and ODN groups at six and 12 months was 97.77 ± 28.25 and 81.73 ± 27.46, and 94.56 ± 28.3 and 85.74 ± 30.1 mL/min/1.73 m2 (p = 0.085, p = 0.344), respectively. The patient and graft survival for both groups were 100% at 12 months post-transplant. In conclusion, the short-term outcome of recipients of kidneys procured via HALDN is comparable to that of kidneys procured via ODN in pediatric patients.
- 1 August 2005
- Published by Wolters Kluwer Health in Transplantation
- Vol. 80 (3) , 310-313
Control of the Renal Artery and Vein with the Nonabsorbable Polymer Ligating Clip in Hand-Assisted Laparoscopic Donor Nephrectomy
The large and variable size of the renal vein has prompted most surgeons to select linear stapling devices to secure the vein during laparoscopic donor nephrectomy. Although effective, these stapling devices have a potential for misfire. Use of the nonabsorbable polymer ligating (NPL) clip during laparoscopic donor nephrectomy provides increased graft vessel length compared with the stapling device, and the NPL clip has a locking mechanism which may increase security compared with standard titanium clips. The objective of this study was to evaluate the safety and efficacy of the NPL clip for control of the renal artery and vein during hand-assisted laparoscopic donor nephrectomy (HALDN). A retrospective chart review of 50 consecutive HALDN patients was conducted where two parallel NPL clips were used to control both the renal artery and vein. Information collected included demographic data, operative and postoperative data, and complications. Mean donor age was 33.4 years and body mass index was 25.8 kg/m2. Mean operative time was 266.0 min, mean hospital stay was 3.2 days, and mean warm ischemia time was 123.3 seconds. There were no transfusions, open conversions, or complications related to use of the NPL clip. A $16,300 disposable cost savings was seen during this 1-year period alone. The NPL clip was 100% safe and effective in controlling the renal artery and vein during HALDN, allowed for additional vessel length, and resulted in a disposable cost savings of $362 per patient.
- 1 August 2005
- Published by Wolters Kluwer Health in Transplantation
- Vol. 80 (3) , 310-313
Control of the Renal Artery and Vein with the Nonabsorbable Polymer Ligating Clip in Hand-Assisted Laparoscopic Donor Nephrectomy
The large and variable size of the renal vein has prompted most surgeons to select linear stapling devices to secure the vein during laparoscopic donor nephrectomy. Although effective, these stapling devices have a potential for misfire. Use of the nonabsorbable polymer ligating (NPL) clip during laparoscopic donor nephrectomy provides increased graft vessel length compared with the stapling device, and the NPL clip has a locking mechanism which may increase security compared with standard titanium clips. The objective of this study was to evaluate the safety and efficacy of the NPL clip for control of the renal artery and vein during hand-assisted laparoscopic donor nephrectomy (HALDN). A retrospective chart review of 50 consecutive HALDN patients was conducted where two parallel NPL clips were used to control both the renal artery and vein. Information collected included demographic data, operative and postoperative data, and complications. Mean donor age was 33.4 years and body mass index was 25.8 kg/m2. Mean operative time was 266.0 min, mean hospital stay was 3.2 days, and mean warm ischemia time was 123.3 seconds. There were no transfusions, open conversions, or complications related to use of the NPL clip. A $16,300 disposable cost savings was seen during this 1-year period alone. The NPL clip was 100% safe and effective in controlling the renal artery and vein during HALDN, allowed for additional vessel length, and resulted in a disposable cost savings of $362 per patient.