Seung-Moo Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Seung-Moo Han has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Mugahed A. Al-Antari
Department of Artificial Intelligence and Data Science, College of AI Convergence, Daeyang AI Center, Sejong University, Seoul, Republic of Korea
6 shared publications - Tae-Seong Kim
Department of Electronics and Information Convergence Engineering, Kyung Hee University, Yongin, Republic of Korea
6 shared publications - Mohammed A. Al-Masni
King Fahd University of Petroleum & Minerals (KFUPM)
5 shared publications - Mun-Taek Choi
Sungkyunkwan University, Suwon, Republic of Korea
3 shared publications - Dildar Hussain
Department of Artificial Intelligence and Data Science, Sejong University, Seoul 05006, Republic of Korea
2 shared publications - Edwin Valarezo Añazco
Escuela Superior Politécnica del Litoral, ESPOL
1 shared publication
Latest Publications
- Top Cited Papers
- 1 November 2020
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 196, 105584
Evaluation of deep learning detection and classification towards computer-aided diagnosis of breast lesions in digital X-ray mammograms
- 1 November 2020
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 196, 105584
Top Cited PapersEvaluation of deep learning detection and classification towards computer-aided diagnosis of breast lesions in digital X-ray mammograms
- 1 May 2019
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 173, 87-107
Computer-aided osteoporosis detection from DXA imaging
- 1 May 2019
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 173, 87-107
Computer-aided osteoporosis detection from DXA imaging
- 1 September 2018
- Published by Elsevier in International Journal of Medical Informatics
- Vol. 117, 44-54
A fully integrated computer-aided diagnosis system for digital X-ray mammograms via deep learning detection, segmentation, and classification
- 1 September 2018
- Published by Elsevier in International Journal of Medical Informatics
- Vol. 117, 44-54
A fully integrated computer-aided diagnosis system for digital X-ray mammograms via deep learning detection, segmentation, and classification
- Top Cited Papers
- 1 August 2018
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 162, 221-231
Skin lesion segmentation in dermoscopy images via deep full resolution convolutional networks
- 1 August 2018
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 162, 221-231
Top Cited PapersSkin lesion segmentation in dermoscopy images via deep full resolution convolutional networks
- 23 July 2018
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 26 (5) , 727-746
Femur segmentation in DXA imaging using a machine learning decision tree
BACKGROUND: Accurate measurement of bone mineral density (BMD) in dual-energy X-ray absorptiometry (DXA) is essential for proper diagnosis of osteoporosis. Calculation of BMD requires precise bone segmentation and subtraction of soft tissue absorption. Femur segmentation remains a challenge as many existing methods fail to correctly distinguish femur from soft tissue. Reasons for this failure include low contrast and noise in DXA images, bone shape variability, and inconsistent X-ray beam penetration and attenuation, which cause shadowing effects and person-to-person variation. OBJECTIVE: To present a new method namely, a Pixel Label Decision Tree (PLDT), and test whether it can achieve higher accurate performance in femur segmentation in DXA imaging. METHODS: PLDT involves mainly feature extraction and selection. Unlike photographic images, X-ray images include features on the surface and inside an object. In order to reveal hidden patterns in DXA images, PLDT generates seven new feature maps from existing high energy (HE) and low energy (LE) X-ray features and determines the best feature set for the model. The performance of PLDT in femur segmentation is compared with that of three widely used medical image segmentation algorithms, the Global Threshold (GT), Region Growing Threshold (RGT), and artificial neural networks (ANN). RESULTS: PLDT achieved a higher accuracy of femur segmentation in DXA imaging (91.4%) than either GT (68.4%), RGT (76%) or ANN (84.4%). CONCLUSIONS: The study demonstrated that PLDT outperformed other conventional segmentation techniques in segmenting DXA images. Improved segmentation should help accurate computation of BMD which later improves clinical diagnosis of osteoporosis.
- 23 July 2018
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 26 (5) , 727-746
Femur segmentation in DXA imaging using a machine learning decision tree
BACKGROUND: Accurate measurement of bone mineral density (BMD) in dual-energy X-ray absorptiometry (DXA) is essential for proper diagnosis of osteoporosis. Calculation of BMD requires precise bone segmentation and subtraction of soft tissue absorption. Femur segmentation remains a challenge as many existing methods fail to correctly distinguish femur from soft tissue. Reasons for this failure include low contrast and noise in DXA images, bone shape variability, and inconsistent X-ray beam penetration and attenuation, which cause shadowing effects and person-to-person variation. OBJECTIVE: To present a new method namely, a Pixel Label Decision Tree (PLDT), and test whether it can achieve higher accurate performance in femur segmentation in DXA imaging. METHODS: PLDT involves mainly feature extraction and selection. Unlike photographic images, X-ray images include features on the surface and inside an object. In order to reveal hidden patterns in DXA images, PLDT generates seven new feature maps from existing high energy (HE) and low energy (LE) X-ray features and determines the best feature set for the model. The performance of PLDT in femur segmentation is compared with that of three widely used medical image segmentation algorithms, the Global Threshold (GT), Region Growing Threshold (RGT), and artificial neural networks (ANN). RESULTS: PLDT achieved a higher accuracy of femur segmentation in DXA imaging (91.4%) than either GT (68.4%), RGT (76%) or ANN (84.4%). CONCLUSIONS: The study demonstrated that PLDT outperformed other conventional segmentation techniques in segmenting DXA images. Improved segmentation should help accurate computation of BMD which later improves clinical diagnosis of osteoporosis.
- Top Cited Papers
- 1 April 2018
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 157, 85-94
Simultaneous detection and classification of breast masses in digital mammograms via a deep learning YOLO-based CAD system
- 1 April 2018
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 157, 85-94
Top Cited PapersSimultaneous detection and classification of breast masses in digital mammograms via a deep learning YOLO-based CAD system
- 25 September 2017
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 38 (3) , 443-456
An Automatic Computer-Aided Diagnosis System for Breast Cancer in Digital Mammograms via Deep Belief Network
- 25 September 2017
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 38 (3) , 443-456
An Automatic Computer-Aided Diagnosis System for Breast Cancer in Digital Mammograms via Deep Belief Network
- 1 April 2005
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 219 (4) , 285-292
A Comparison of Ultrasonic and X-ray Methods for Imaging the Growth Plate
The purpose of this study was to assess a systematic and scientific method for measuring children's growth development, in which the accuracy of the existing diagnostic method has not yet been concretely examined. The most popular method for diagnosis of children's growth is to analyse the opening degree of the growth plate in each joint by an X-ray image. However, the X-ray method has some disadvantages; it is impossible to measure the diagnosis of growth periodically and repeatedly due to the radiation problem. Hence, this study introduced a profile analysis and the algorithm of analysing the image of the growth plate using the broadband ultrasound attenuation (BUA) of calcaneus, to verify the possibility of using an alternative ultrasonic method harmless to the human body. The images of the growth plate in the proximal tibiae, phalanges, and calcanei of 269 children (7–16 years old) were obtained using X-ray. The image of the growth plate in the calcanei was also obtained from these children using ultrasound. The results showed that the time of the opening degree of the growth plate in each joint was almost consistent between X-ray and ultrasonic images. Also, the images of the growth plate measured using X-ray and ultrasound showed a high correlation. Therefore, it is expected that the algorithm of ultrasonic profile analysis introduced in this study can replace the existing X-ray method to measure the growth plate correctly.
- 1 April 2005
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 219 (4) , 285-292
A Comparison of Ultrasonic and X-ray Methods for Imaging the Growth Plate
The purpose of this study was to assess a systematic and scientific method for measuring children's growth development, in which the accuracy of the existing diagnostic method has not yet been concretely examined. The most popular method for diagnosis of children's growth is to analyse the opening degree of the growth plate in each joint by an X-ray image. However, the X-ray method has some disadvantages; it is impossible to measure the diagnosis of growth periodically and repeatedly due to the radiation problem. Hence, this study introduced a profile analysis and the algorithm of analysing the image of the growth plate using the broadband ultrasound attenuation (BUA) of calcaneus, to verify the possibility of using an alternative ultrasonic method harmless to the human body. The images of the growth plate in the proximal tibiae, phalanges, and calcanei of 269 children (7–16 years old) were obtained using X-ray. The image of the growth plate in the calcanei was also obtained from these children using ultrasound. The results showed that the time of the opening degree of the growth plate in each joint was almost consistent between X-ray and ultrasonic images. Also, the images of the growth plate measured using X-ray and ultrasound showed a high correlation. Therefore, it is expected that the algorithm of ultrasonic profile analysis introduced in this study can replace the existing X-ray method to measure the growth plate correctly.