Aurel Ymeti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Aurel Ymeti has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Arjan G.J. Tibbe
Immunicon Europe Inc., Hengelosestraat 705, 7521 PA Enschede, The Netherlands
1 shared publicationBjörn Lunter
University of Twente, Faculty of Science and Technology, Biophysical Engineering Group, Building Zuidhorst, Dienstweg 1, 7522 ND Enschede, The Netherlands
1 shared publication- Christian Breukers
Medical Cell BioPhysics Group, Technical Medical Centre, University of Twente, 7522 NB Enschede, The Netherlands
1 shared publication Jan Greve
University of Twente, Faculty of Science and Technology, Biophysical Engineering Group, Building Zuidhorst, Dienstweg 1, 7522 ND Enschede, The Netherlands
1 shared publication- Jan Willem Greve
Nederlandse Obesitas Kliniek (Dutch Obesity Clinic), Huis Ter Heide, Netherlands
1 shared publication Johannes S. Kanger
A. Ymeti, J. Greve, P. V. Lembeck, and J. S. Kanger are with the University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands, in the following departments: MESA+ Institute for Nanotechnology (A. Ymeti, J. Greve, and P. V. Lembeck), Biophysical Engineering Group, Faculty of Science and Technology (A. Ymeti, J. Greve, and J. S. Kanger); Integrated Optical Microsystems, Faculty of Electrical Engineering, Mathematics, and Computer Science (P. V. Lembeck)
1 shared publication
Latest Publications
- 14 August 2007
- Published by Wiley in Cytometry Part B: Clinical Cytometry
- Vol. 72B (5) , 397-407
CD4+ T lymphocytes enumeration by an easy‐to‐use single platform image cytometer for HIV monitoring in resource‐constrained settings
Background: HIV monitoring in resource‐constrained settings demands affordable and reliable CD4+ T lymphocytes enumeration methods. We developed a simple single platform image cytometer (SP ICM), which is a dedicated volumetric CD4+ T lymphocytes enumeration system that uses immunomagnetic and immunofluorescent technologies. The instrument was designed to be a low‐cost, yet reliable and robust one. In this article we test the instrument and the immunochemical procedures used on blood from HIV negative and HIV positive patients. Methods: After CD4 immunomagnetic labeling in whole blood, CD4+ T lymphocytes, CD4+dim monocytes and some nonspecifically labeled cells are magnetically attracted to an analysis surface. Combining with CD3‐Phycoerythrin (PE) labeling, only CD3+CD4+ T lymphocytes are fluorescently labeled and visible in a fluorescent image of the analysis surface. The number of CD4+ T lymphocytes is obtained by image analysis. Alternatively, CD3 immunomagnetic selection in combination with CD4 immunofluorescent labeling can also be applied for CD4+ T lymphocytes enumeration. Results: The SP ICM system was compared with two single platform flow cytometer (SP FCM) methods: tetraCXP and TruCount methods. The SP ICM system has excellent precision, accuracy and linearity for CD4+ T lymphocytes enumeration. Good correlations were obtained between the SP ICM and the SP FCM methods for blood specimens of 44 HIV− patients, and of 63 HIV+ patients. Bland–Altman plots showed interchangeability between the SP ICM and the SP FCM methods. Conclusions: The immunolabeling methods and the instrumentation are simple and easy‐to‐handle for less‐trained operators. The SP ICM system is a good candidate for CD4+ T lymphocytes enumeration in point‐of‐care settings of resource‐constrained countries. © 2007 Clinical Cytometry Society.
- 14 August 2007
- Published by Wiley in Cytometry Part B: Clinical Cytometry
- Vol. 72B (5) , 397-407
CD4+ T lymphocytes enumeration by an easy‐to‐use single platform image cytometer for HIV monitoring in resource‐constrained settings
Background: HIV monitoring in resource‐constrained settings demands affordable and reliable CD4+ T lymphocytes enumeration methods. We developed a simple single platform image cytometer (SP ICM), which is a dedicated volumetric CD4+ T lymphocytes enumeration system that uses immunomagnetic and immunofluorescent technologies. The instrument was designed to be a low‐cost, yet reliable and robust one. In this article we test the instrument and the immunochemical procedures used on blood from HIV negative and HIV positive patients. Methods: After CD4 immunomagnetic labeling in whole blood, CD4+ T lymphocytes, CD4+dim monocytes and some nonspecifically labeled cells are magnetically attracted to an analysis surface. Combining with CD3‐Phycoerythrin (PE) labeling, only CD3+CD4+ T lymphocytes are fluorescently labeled and visible in a fluorescent image of the analysis surface. The number of CD4+ T lymphocytes is obtained by image analysis. Alternatively, CD3 immunomagnetic selection in combination with CD4 immunofluorescent labeling can also be applied for CD4+ T lymphocytes enumeration. Results: The SP ICM system was compared with two single platform flow cytometer (SP FCM) methods: tetraCXP and TruCount methods. The SP ICM system has excellent precision, accuracy and linearity for CD4+ T lymphocytes enumeration. Good correlations were obtained between the SP ICM and the SP FCM methods for blood specimens of 44 HIV− patients, and of 63 HIV+ patients. Bland–Altman plots showed interchangeability between the SP ICM and the SP FCM methods. Conclusions: The immunolabeling methods and the instrumentation are simple and easy‐to‐handle for less‐trained operators. The SP ICM system is a good candidate for CD4+ T lymphocytes enumeration in point‐of‐care settings of resource‐constrained countries. © 2007 Clinical Cytometry Society.
- Open Access
- 10 June 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (17) , 3409-3412
Drift correction in a multichannel integrated optical Young interferometer
We demonstrate that in a sensor based on a multichannel Young interferometer, the phase information obtained for different pairs of channels can be used to correct the long-term instability (drift) due to temperature differences between measuring and reference channels, the drift in the alignment of the setup, etc. Experiments show that the nature of a major part of the drift is such that the drift present in one of the channels can be determined by interpolation of the drift measured in the two adjacent channels. It is shown that a drift reduction of 10 times can be achieved as compared with the situation in which no correction is applied. We anticipate that these findings will permit the exploitation of the extreme sensitivity of interference-based sensors to a much greater extent.
- 10 June 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (17) , 3409-3412
Open AccessDrift correction in a multichannel integrated optical Young interferometer
We demonstrate that in a sensor based on a multichannel Young interferometer, the phase information obtained for different pairs of channels can be used to correct the long-term instability (drift) due to temperature differences between measuring and reference channels, the drift in the alignment of the setup, etc. Experiments show that the nature of a major part of the drift is such that the drift present in one of the channels can be determined by interpolation of the drift measured in the two adjacent channels. It is shown that a drift reduction of 10 times can be achieved as compared with the situation in which no correction is applied. We anticipate that these findings will permit the exploitation of the extreme sensitivity of interference-based sensors to a much greater extent.