Armin Werber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Armin Werber has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Hans Zappe
University of Freiburg
2 shared publications - Claudia Heilmann
Department of Cardiovascular Surgery, Heart Center Freiburg University, Freiburg, Germany
1 shared publication - Friedhelm Beyersdorf
Department of Cardiovascular Surgery, University Hospital Freiburg
1 shared publication - Jens Fiala
Department of Microsystems Engineering (IMTEK), Laboratory for Micro-Optics, University of Freiburg, Georges-Koehler-Allee 102, Freiburg, 79110, Germany
1 shared publication - Katharina Förster
Center for Experimental Models and Transgenic Service, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Stefan-Meier-Str. 17, D-79104 Freiburg, Germany
1 shared publication Philipp Bingger
1 shared publication
Latest Publications
- 1 January 2007
- Published by Optica Publishing Group
Miniaturized pulse oximeter sensor for continuous vital parameter monitoring
A miniaturized photoplethysmographic sensor system which utilizes the principle of pulse oximetry is presented. The sensor is designed to be implantable and will permit continuous monitoring of important human vital parameters such as arterial blood oxygen saturation as well as pulse rate and shape over a long-term period in vivo. The system employs light emitting diodes and a photo transistor embedded in a transparent elastic cuff which is directly wrapped around an arterial vessel. This paper highlights the specific challenges in design, instrumentation, and electronics associated with that sensor location. In vitro measurements were performed using an artificial circulation system which allows for regulation of the oxygen saturation and pulsatile pumping of whole blood through a section of a domestic pig's arterial vessel. We discuss our experimental results compared to reference CO-oximeter measurements and determine the empirical calibration curve. These results demonstrate the capabilities of the pulse oximeter implant for measurement of a wide range of oxygen saturation levels and pave the way for a continuous and mobile monitoring of high-risk cardiovascular patients.
- 1 January 2007
- Published by Optica Publishing Group
Miniaturized pulse oximeter sensor for continuous vital parameter monitoring
A miniaturized photoplethysmographic sensor system which utilizes the principle of pulse oximetry is presented. The sensor is designed to be implantable and will permit continuous monitoring of important human vital parameters such as arterial blood oxygen saturation as well as pulse rate and shape over a long-term period in vivo. The system employs light emitting diodes and a photo transistor embedded in a transparent elastic cuff which is directly wrapped around an arterial vessel. This paper highlights the specific challenges in design, instrumentation, and electronics associated with that sensor location. In vitro measurements were performed using an artificial circulation system which allows for regulation of the oxygen saturation and pulsatile pumping of whole blood through a section of a domestic pig's arterial vessel. We discuss our experimental results compared to reference CO-oximeter measurements and determine the empirical calibration curve. These results demonstrate the capabilities of the pulse oximeter implant for measurement of a wide range of oxygen saturation levels and pave the way for a continuous and mobile monitoring of high-risk cardiovascular patients.
- 1 June 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (16) , 3238-3245
Tunable microfluidic microlenses
A novel type of liquid microlens, bounded by a microfabricated, distensible membrane and activated by a microfluidic liquid-handling system, is presented. By use of an elastomer membrane fabricated by spin coating onto a dry-etched silicon substrate, the liquid-filled cavity acts as a lens whereby applied pressure changes the membrane distension and thus the focal length. Both plano–convex and plano–concave lenses, individual elements as well as arrays, were fabricated and tested. The lens surface roughness was seen to be ∼9 nm rms, and the focal length could be tuned from 1 to 18 mm. This lens represents a robust, self-contained tunable optical structure suitable for use in, for example, a medical environment.
- 1 June 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (16) , 3238-3245
Tunable microfluidic microlenses
A novel type of liquid microlens, bounded by a microfabricated, distensible membrane and activated by a microfluidic liquid-handling system, is presented. By use of an elastomer membrane fabricated by spin coating onto a dry-etched silicon substrate, the liquid-filled cavity acts as a lens whereby applied pressure changes the membrane distension and thus the focal length. Both plano–convex and plano–concave lenses, individual elements as well as arrays, were fabricated and tested. The lens surface roughness was seen to be ∼9 nm rms, and the focal length could be tuned from 1 to 18 mm. This lens represents a robust, self-contained tunable optical structure suitable for use in, for example, a medical environment.