Pierre-Henri Jarreau
Research Subjects
Research Interests
Pierre-Henri Jarreau has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Guy Moriette
3 shared publicationsAlain Harf
Service de Médecine Néonatale de Port-Royal, Centre Hospitalier Universitaire Cochin, Assistance Publique-Hôpitaux de Paris-Université Paris V, Paris; and Institut National de la Santé et de la Recherche Médicale INSERM U 492, and Service de Physiologie-Explorations fonctionnelles, Centre Hospitalier Universitaire Henri Mondor, Assistance Publique-Hôpitaux de Paris-Université Paris XII, Créteil, France
2 shared publications- Bruno Louis
CNRS EMR 7000 Créteil France
2 shared publications - Daniel Isabey
INSERM
2 shared publications Anne Brunhes
1 shared publicationAude Coffinières
1 shared publication
Latest Publications
- 28 February 2005
- Published by Elsevier in Journal de Gynécologie Obstétrique et Biologie de la Reproduction
- Vol. 34 (1) , 37-41
Sevrage de l’oxygène
- 28 February 2005
- Published by Elsevier in Journal de Gynécologie Obstétrique et Biologie de la Reproduction
- Vol. 34 (1) , 37-41
Sevrage de l’oxygène
- 1 January 2001
- Published by Wiley in Pediatric Pulmonology
- Vol. 26 (S23) , 100-102
Management of respiratory distress syndrome: An update
- 1 January 2001
- Published by Wiley in Pediatric Pulmonology
- Vol. 26 (S23) , 100-102
Management of respiratory distress syndrome: An update
- 1 May 2000
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 161 (5) , 1754-1756
Detection of Positional Airway Obstruction in Neonates by Acoustic Reflection
In neonates intubated with an uncuffed endotracheal tube (ETT), positional changes of the head may induce obstruction (side position-related ETT obstruction [SPRO]) due to abutment of the beveled distal ETT orifice against the tracheal wall. We studied whether the acoustic reflection (ACR) method, a 4-s measurement that maps cross-sectional area as a function of the distance along the ETT and the airways, could detect SPRO. Eleven preterm newborns intubated with 2.5-mm ETTs and clinically suspected of having SPRO were studied with the head oriented to the left and to the right. In all patients there was a marked decrease in the ACR-measured area beyond the distal tip of the ETT in the presence of obstruction (decrease = 38 ± 22% [mean ± SD] of the ETT inside area), while the ACR-measured area increased markedly in the absence of obstruction (increase = 49 ± 17%). For six of the 11 infants, we also recorded the maximal flow produced by a set mechanical inflation pressure. This maximal flow decreased in the presence of obstruction (decrease = 47 ± 18%), and was constantly associated with a decrease in ACR-measured area beyond the ETT. In conclusion, ACR measurement is an efficient method for diagnosing positional ETT obstruction in intubated newborns.
- 1 May 2000
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 161 (5) , 1754-1756
Detection of Positional Airway Obstruction in Neonates by Acoustic Reflection
In neonates intubated with an uncuffed endotracheal tube (ETT), positional changes of the head may induce obstruction (side position-related ETT obstruction [SPRO]) due to abutment of the beveled distal ETT orifice against the tracheal wall. We studied whether the acoustic reflection (ACR) method, a 4-s measurement that maps cross-sectional area as a function of the distance along the ETT and the airways, could detect SPRO. Eleven preterm newborns intubated with 2.5-mm ETTs and clinically suspected of having SPRO were studied with the head oriented to the left and to the right. In all patients there was a marked decrease in the ACR-measured area beyond the distal tip of the ETT in the presence of obstruction (decrease = 38 ± 22% [mean ± SD] of the ETT inside area), while the ACR-measured area increased markedly in the absence of obstruction (increase = 49 ± 17%). For six of the 11 infants, we also recorded the maximal flow produced by a set mechanical inflation pressure. This maximal flow decreased in the presence of obstruction (decrease = 47 ± 18%), and was constantly associated with a decrease in ACR-measured area beyond the ETT. In conclusion, ACR measurement is an efficient method for diagnosing positional ETT obstruction in intubated newborns.
- 1 July 1999
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 87 (1) , 36-46
Estimation of inspiratory pressure drop in neonatal and pediatric endotracheal tubes
Endotracheal tubes (ETTs) constitute a resistive extra load for intubated patients. The ETT pressure drop (ΔPETT) is usually described by empirical equations that are specific to one ETT only. Our laboratory previously showed that, in adult ETTs, ΔPETT is given by the Blasius formula (F. Lofaso, B. Louis, L. Brochard, A. Harf, and D. Isabey. Am. Rev. Respir. Dis. 146: 974–979, 1992). Here, we also propose a general formulation for neonatal and pediatric ETTs on the basis of adimensional analysis of the pressure-flow relationship. Pressure and flow were directly measured in seven ETTs (internal diameter: 2.5–7.0 mm). The measured pressure drop was compared with the predicted drop given by general laws for a curved tube. In neonatal ETTs (2.5–3.5 mm) the flow regime is laminar. The ΔPETT can be estimated by the Ito formula, which replaces Poiseuille’s law for curved tubes. For pediatric ETTs (4.0–7.0 mm), ΔPETT depends on the following flow regime: for laminar flow, it must be calculated by the Ito formula, and for turbulent flow, by the Blasius formula. Both formulas allow for ETT geometry and gas properties.
- 1 July 1999
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 87 (1) , 36-46
Estimation of inspiratory pressure drop in neonatal and pediatric endotracheal tubes
Endotracheal tubes (ETTs) constitute a resistive extra load for intubated patients. The ETT pressure drop (ΔPETT) is usually described by empirical equations that are specific to one ETT only. Our laboratory previously showed that, in adult ETTs, ΔPETT is given by the Blasius formula (F. Lofaso, B. Louis, L. Brochard, A. Harf, and D. Isabey. Am. Rev. Respir. Dis. 146: 974–979, 1992). Here, we also propose a general formulation for neonatal and pediatric ETTs on the basis of adimensional analysis of the pressure-flow relationship. Pressure and flow were directly measured in seven ETTs (internal diameter: 2.5–7.0 mm). The measured pressure drop was compared with the predicted drop given by general laws for a curved tube. In neonatal ETTs (2.5–3.5 mm) the flow regime is laminar. The ΔPETT can be estimated by the Ito formula, which replaces Poiseuille’s law for curved tubes. For pediatric ETTs (4.0–7.0 mm), ΔPETT depends on the following flow regime: for laminar flow, it must be calculated by the Ito formula, and for turbulent flow, by the Blasius formula. Both formulas allow for ETT geometry and gas properties.