William P. Argo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
William P. Argo has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- David E. Hintenlang
Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, Florida 32611-8300, and Department of Biomedical Engineering, University of Florida, Gainesville, Florida 32611-6131
1 shared publication - Kathleen Hintenlang
Robert Boissenault Oncology Institute Timber Ridge Medical Plaza 9401 SW Hwy 200, Bldg 800 Ocala Florida 34481 U.S.A.
1 shared publication
Latest Publications
- Open Access
- 1 September 2004
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 5 (4) , 112-119
A tissue‐equivalent phantom series for mammography dosimetry
A breast tissue equivalent series (BRTES) of phantoms are manufactured to mimic both the attenuation and density of the range of glandular and adipose tissue compositions encountered in mammography. The BRTES simulates breast tissues across the range of 20 to 70 % glandularity and can be assembled in a variety of thicknesses to represent a compressed breast thickness corresponding to glandularity to simulate various patient demographics. The fabrication techniques are presented and physical properties of the completed series of phantoms are described. The BRTES phantoms provide a dosimetry comparison with commonly used phantoms, including the ACR accreditation phantom and BR12, a 50% glandularity tissue equivalent material. The comparison shows that the mean glandular dose is a strong function of compressed breast thickness and tissue composition. Patient doses measured using phototimed exposures with the BRTES phantoms can be a factor of two greater than, or less than, the doses predicted using conventional phantoms.
- 1 September 2004
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 5 (4) , 112-119
Open AccessA tissue‐equivalent phantom series for mammography dosimetry
A breast tissue equivalent series (BRTES) of phantoms are manufactured to mimic both the attenuation and density of the range of glandular and adipose tissue compositions encountered in mammography. The BRTES simulates breast tissues across the range of 20 to 70 % glandularity and can be assembled in a variety of thicknesses to represent a compressed breast thickness corresponding to glandularity to simulate various patient demographics. The fabrication techniques are presented and physical properties of the completed series of phantoms are described. The BRTES phantoms provide a dosimetry comparison with commonly used phantoms, including the ACR accreditation phantom and BR12, a 50% glandularity tissue equivalent material. The comparison shows that the mean glandular dose is a strong function of compressed breast thickness and tissue composition. Patient doses measured using phototimed exposures with the BRTES phantoms can be a factor of two greater than, or less than, the doses predicted using conventional phantoms.