George J. Knight
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
George J. Knight has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- J. E. Haddow
Women and Infants Hospital and Alpert Medical School of Brown University, Providence, RI
7 shared publications G E Palomaki
6 shared publicationsGlenn E Palomaki
2 shared publicationsJ A Canick
2 shared publicationsA A Pollak
Dept. Neonat., Univ. of, Vienna, Austria
1 shared publicationA Kennard
1 shared publication
Latest Publications
- 1 March 2005
- Published by Wiley in Archives of Pathology & Laboratory Medicine
- Vol. 129 (3) , 328-30
A comparison of human chorionic gonadotropin- related components in fresh frozen serum with the proficiency testing material used by the College of American Pathologists.
As part of a College of American Pathologists (CAP) proficiency testing survey, a comparison is made between human chorionic gonadotropin (hCG) results from an actual patient pool and a similarly targeted artificial sample. The goal is to gain insight into the possible source(s) of bias attributable to the proficiency testing material (PTM) with a view toward creating more appropriate survey materials. To compare hCG and related variants in a pool of fresh frozen sera (FFS) with that found in PTM. The 2003 CAP K/KN-A Survey included a FFS specimen along with admixtures of PTM. The FFS (K-02) and 1 PTM admixture (K-01) had similar mean hCG values. Five hCG-related analytes were measured on these 2 samples by a reference laboratory. Approximately 1800 clinical laboratories and diagnostic test kit manufacturers participated in the K/ KN-A Survey. Method imprecision (coefficient of variation) and method bias (relative difference between peer group mean and all-method median) were computed for the 2 samples. Differences were evaluated with respect to hCG-related analytes levels. All-method hCG results were 12.9 mIU/mL (12.9 IU/L) for the PTM material and 21.6 mIU/mL (21.6 IU/L) for the FFS material. Method biases for 14 manufacturers were greater for PTM than for FFS (-40% to +35% and -16% to +23%). Twelve of 14 methods had higher coefficients of variation on PTM. Total hCG and free beta hCG measurements by the reference laboratory were 14.1 mIU/ mL (14.1 IU/L) for the PTM material and 18.5 mIU/mL (18.5 U/L) for the FFS material (FFS), and 2.4 (PTM) and 0.7 (FFS) mIU/mL (2.4 and 0.7 IU/L), respectively. On a molar basis, free beta represented 17% and 4% of the total hCG, respectively. Levels of hyperglycosylated hCG, nicked hCG, and beta core fragment were not measurable in either sample. It is unlikely that the hCG added to the PTM is the source of the increased bias and variability. The main difference is a 3-fold increase in free beta found in the PTM, but methods previously found to strongly react with free beta were not systematically elevated. The biases between manufacturers found for the FFS specimen are likely attributable to calibration differences.
- 1 March 2005
- Published by Wiley in Archives of Pathology & Laboratory Medicine
- Vol. 129 (3) , 328-30
A comparison of human chorionic gonadotropin- related components in fresh frozen serum with the proficiency testing material used by the College of American Pathologists.
As part of a College of American Pathologists (CAP) proficiency testing survey, a comparison is made between human chorionic gonadotropin (hCG) results from an actual patient pool and a similarly targeted artificial sample. The goal is to gain insight into the possible source(s) of bias attributable to the proficiency testing material (PTM) with a view toward creating more appropriate survey materials. To compare hCG and related variants in a pool of fresh frozen sera (FFS) with that found in PTM. The 2003 CAP K/KN-A Survey included a FFS specimen along with admixtures of PTM. The FFS (K-02) and 1 PTM admixture (K-01) had similar mean hCG values. Five hCG-related analytes were measured on these 2 samples by a reference laboratory. Approximately 1800 clinical laboratories and diagnostic test kit manufacturers participated in the K/ KN-A Survey. Method imprecision (coefficient of variation) and method bias (relative difference between peer group mean and all-method median) were computed for the 2 samples. Differences were evaluated with respect to hCG-related analytes levels. All-method hCG results were 12.9 mIU/mL (12.9 IU/L) for the PTM material and 21.6 mIU/mL (21.6 IU/L) for the FFS material. Method biases for 14 manufacturers were greater for PTM than for FFS (-40% to +35% and -16% to +23%). Twelve of 14 methods had higher coefficients of variation on PTM. Total hCG and free beta hCG measurements by the reference laboratory were 14.1 mIU/ mL (14.1 IU/L) for the PTM material and 18.5 mIU/mL (18.5 U/L) for the FFS material (FFS), and 2.4 (PTM) and 0.7 (FFS) mIU/mL (2.4 and 0.7 IU/L), respectively. On a molar basis, free beta represented 17% and 4% of the total hCG, respectively. Levels of hyperglycosylated hCG, nicked hCG, and beta core fragment were not measurable in either sample. It is unlikely that the hCG added to the PTM is the source of the increased bias and variability. The main difference is a 3-fold increase in free beta found in the PTM, but methods previously found to strongly react with free beta were not systematically elevated. The biases between manufacturers found for the FFS specimen are likely attributable to calibration differences.
- Open Access
- 1 March 2005
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 129 (3) , 328-330
A Comparison of Human Chorionic Gonadotropin– Related Components in Fresh Frozen Serum With the Proficiency Testing Material Used by the College of American Pathologists
Context. —As part of a College of American Pathologists (CAP) proficiency testing survey, a comparison is made between human chorionic gonadotropin (hCG) results from an actual patient pool and a similarly targeted artificial sample. The goal is to gain insight into the possible source(s) of bias attributable to the proficiency testing material (PTM) with a view toward creating more appropriate survey materials. Objective. —To compare hCG and related variants in a pool of fresh frozen sera (FFS) with that found in PTM. Design. —The 2003 CAP K/KN-A Survey included a FFS specimen along with admixtures of PTM. The FFS (K-02) and 1 PTM admixture (K-01) had similar mean hCG values. Five hCG-related analytes were measured on these 2 samples by a reference laboratory. Participants. —Approximately 1800 clinical laboratories and diagnostic test kit manufacturers participated in the K/ KN-A Survey. Main Outcome Measures. —Method imprecision (coefficient of variation) and method bias (relative difference between peer group mean and all-method median) were computed for the 2 samples. Differences were evaluated with respect to hCG-related analytes levels. Results. —All-method hCG results were 12.9 mIU/mL (12.9 IU/L) for the PTM material and 21.6 mIU/mL (21.6 IU/L) for the FFS material. Method biases for 14 manufacturers were greater for PTM than for FFS (−40% to +35% and −16% to +23%). Twelve of 14 methods had higher coefficients of variation on PTM. Total hCG and free β hCG measurements by the reference laboratory were 14.1 mIU/ mL (14.1 IU/L) for the PTM material and 18.5 mIU/mL (18.5 U/L) for the FFS material (FFS), and 2.4 (PTM) and 0.7 (FFS) mIU/mL (2.4 and 0.7 IU/L), respectively. On a molar basis, free β represented 17% and 4% of the total hCG, respectively. Levels of hyperglycosylated hCG, nicked hCG, and β core fragment were not measurable in either sample. Conclusions. —It is unlikely that the hCG added to the PTM is the source of the increased bias and variability. The main difference is a 3-fold increase in free β found in the PTM, but methods previously found to strongly react with free β were not systematically elevated. The biases between manufacturers found for the FFS specimen are likely attributable to calibration differences.
- 1 March 2005
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 129 (3) , 328-330
Open AccessA Comparison of Human Chorionic Gonadotropin– Related Components in Fresh Frozen Serum With the Proficiency Testing Material Used by the College of American Pathologists
Context. —As part of a College of American Pathologists (CAP) proficiency testing survey, a comparison is made between human chorionic gonadotropin (hCG) results from an actual patient pool and a similarly targeted artificial sample. The goal is to gain insight into the possible source(s) of bias attributable to the proficiency testing material (PTM) with a view toward creating more appropriate survey materials. Objective. —To compare hCG and related variants in a pool of fresh frozen sera (FFS) with that found in PTM. Design. —The 2003 CAP K/KN-A Survey included a FFS specimen along with admixtures of PTM. The FFS (K-02) and 1 PTM admixture (K-01) had similar mean hCG values. Five hCG-related analytes were measured on these 2 samples by a reference laboratory. Participants. —Approximately 1800 clinical laboratories and diagnostic test kit manufacturers participated in the K/ KN-A Survey. Main Outcome Measures. —Method imprecision (coefficient of variation) and method bias (relative difference between peer group mean and all-method median) were computed for the 2 samples. Differences were evaluated with respect to hCG-related analytes levels. Results. —All-method hCG results were 12.9 mIU/mL (12.9 IU/L) for the PTM material and 21.6 mIU/mL (21.6 IU/L) for the FFS material. Method biases for 14 manufacturers were greater for PTM than for FFS (−40% to +35% and −16% to +23%). Twelve of 14 methods had higher coefficients of variation on PTM. Total hCG and free β hCG measurements by the reference laboratory were 14.1 mIU/ mL (14.1 IU/L) for the PTM material and 18.5 mIU/mL (18.5 U/L) for the FFS material (FFS), and 2.4 (PTM) and 0.7 (FFS) mIU/mL (2.4 and 0.7 IU/L), respectively. On a molar basis, free β represented 17% and 4% of the total hCG, respectively. Levels of hyperglycosylated hCG, nicked hCG, and β core fragment were not measurable in either sample. Conclusions. —It is unlikely that the hCG added to the PTM is the source of the increased bias and variability. The main difference is a 3-fold increase in free β found in the PTM, but methods previously found to strongly react with free β were not systematically elevated. The biases between manufacturers found for the FFS specimen are likely attributable to calibration differences.
- 1 June 2003
- Published by Elsevier in Clinics In Laboratory Medicine
- Vol. 23 (2) , 531-551
Epidemiologic monitoring of prenatal screening for neural tube defects and Down syndrome
- 1 June 2003
- Published by Elsevier in Clinics In Laboratory Medicine
- Vol. 23 (2) , 531-551
Epidemiologic monitoring of prenatal screening for neural tube defects and Down syndrome
- Open Access
- 1 March 2001
- Published by SAGE Publications in Journal of Medical Screening
- Vol. 8 (1) , 2-7
Clinical validation of a new dimeric inhibin-A assay suitable for second trimester Down's syndrome screening
Objective To compare the Down's syndrome screening performance of a simplified dimeric inhibin-A assay (Diagnostic Systems Laboratories (DSL)) with an assay whose clinical utility has been established (Serotec). Setting A case control set consisting of 51 Down's syndrome and 245 matched unaffected pregnancies collected as part of an earlier multicentre cohort study. Methods Sera were assayed for dimeric inhibin-A using the DSL assay and Serotec reference assay. Data analysis included a method comparison of mass values, fit of data to a logarithmic Gaussian distribution, and determination of detection and false positive rates. In addition, 234 fresh sera were assayed using the simplified method. Results The two assays showed a high correlation (r =0.93) but average concentrations of the DSL assay were 48% higher. However, the differences were basically proportional over the range of values important for screening. The detection rate was essentially equivalent for the DSL assay whether analysed univariately or in combination with other markers (for example, 79% v 75% at a 5% false positive rate for the DSL and Serotec assays for the combination of α fetoprotein, unconjugated oestriol, human chorionic gonadotrophin, and dimeric inhibin-A, respectively). The 234 dimeric inhibin-A values measured on fresh sera fitted a logarithm Gaussian distribution for the DSL assay, as indicated by the fit to a probability plot. Conclusions The Down's syndrome screening performance of a simplified dimeric inhibin-A immunoassay was equivalent to a more labour intensive established dimeric inhibin-A assay.
- 1 March 2001
- Published by SAGE Publications in Journal of Medical Screening
- Vol. 8 (1) , 2-7
Open AccessClinical validation of a new dimeric inhibin-A assay suitable for second trimester Down's syndrome screening
Objective To compare the Down's syndrome screening performance of a simplified dimeric inhibin-A assay (Diagnostic Systems Laboratories (DSL)) with an assay whose clinical utility has been established (Serotec). Setting A case control set consisting of 51 Down's syndrome and 245 matched unaffected pregnancies collected as part of an earlier multicentre cohort study. Methods Sera were assayed for dimeric inhibin-A using the DSL assay and Serotec reference assay. Data analysis included a method comparison of mass values, fit of data to a logarithmic Gaussian distribution, and determination of detection and false positive rates. In addition, 234 fresh sera were assayed using the simplified method. Results The two assays showed a high correlation (r =0.93) but average concentrations of the DSL assay were 48% higher. However, the differences were basically proportional over the range of values important for screening. The detection rate was essentially equivalent for the DSL assay whether analysed univariately or in combination with other markers (for example, 79% v 75% at a 5% false positive rate for the DSL and Serotec assays for the combination of α fetoprotein, unconjugated oestriol, human chorionic gonadotrophin, and dimeric inhibin-A, respectively). The 234 dimeric inhibin-A values measured on fresh sera fitted a logarithm Gaussian distribution for the DSL assay, as indicated by the fit to a probability plot. Conclusions The Down's syndrome screening performance of a simplified dimeric inhibin-A immunoassay was equivalent to a more labour intensive established dimeric inhibin-A assay.
- 1 September 1996
- Published by Springer Nature in Pediatric Research
- Vol. 40 (3) , 533
Fetal and Maternal Carboxyhemoglobin Levels at Cordocentesis in Normal and Abnormal Pregnancy 107
- 1 September 1996
- Published by Springer Nature in Pediatric Research
- Vol. 40 (3) , 533
Fetal and Maternal Carboxyhemoglobin Levels at Cordocentesis in Normal and Abnormal Pregnancy 107
- 1 June 1996
- Vol. 347 (9014) , 1553
Computer software programs and Down's syndrome risk calculations.
- 1 November 1994
- Vol. 84 (5) , 852-5
Second-trimester maternal serum alpha-fetoprotein, unconjugated estriol, and hCG levels in pregnancies with ventral wall defects.
To determine if second-trimester maternal serum concentrations of unconjugated estriol (E3) and hCG are altered in pregnancies associated with fetal gastroschisis or omphalocele. Concentrations of alpha-fetoprotein (AFP), unconjugated E3, and hCG were measured in a case-control study involving 23 cases of gastroschisis, 17 cases of omphalocele, and 200 matched unaffected pregnancies. As reported previously, median AFP levels were significantly higher in pregnancies with gastroschisis and omphalocele compared to unaffected pregnancies (9.42 and 4.18 multiples of the unaffected population median [MoM], respectively). The median hCG values were not significantly different for the two defects (1.10 and 1.13 MoM, respectively). Six of the cases of omphalocele were associated with other anomalies, but exclusion of these cases from the analysis did not alter the conclusions. Unconjugated E3 and hCG measurements are not useful in screening for, or distinguishing between, open ventral wall defects. Alpha-fetoprotein measurements alone will detect nearly all cases of gastroschisis and most cases of omphalocele.
- 1 November 1994
- Vol. 84 (5) , 852-5
Second-trimester maternal serum alpha-fetoprotein, unconjugated estriol, and hCG levels in pregnancies with ventral wall defects.
To determine if second-trimester maternal serum concentrations of unconjugated estriol (E3) and hCG are altered in pregnancies associated with fetal gastroschisis or omphalocele. Concentrations of alpha-fetoprotein (AFP), unconjugated E3, and hCG were measured in a case-control study involving 23 cases of gastroschisis, 17 cases of omphalocele, and 200 matched unaffected pregnancies. As reported previously, median AFP levels were significantly higher in pregnancies with gastroschisis and omphalocele compared to unaffected pregnancies (9.42 and 4.18 multiples of the unaffected population median [MoM], respectively). The median hCG values were not significantly different for the two defects (1.10 and 1.13 MoM, respectively). Six of the cases of omphalocele were associated with other anomalies, but exclusion of these cases from the analysis did not alter the conclusions. Unconjugated E3 and hCG measurements are not useful in screening for, or distinguishing between, open ventral wall defects. Alpha-fetoprotein measurements alone will detect nearly all cases of gastroschisis and most cases of omphalocele.
- 24 February 1994
- Vol. 330 (8)
Prenatal ultrasound screening and perinatal outcome.
- 1 May 1993
- Vol. 81, 675-8
Cigarette smoking and levels of maternal serum alpha-fetoprotein, unconjugated estriol, and hCG: impact on Down syndrome screening.
To investigate the association between maternal cigarette smoking and serum levels of alpha-fetoprotein (AFP), unconjugated estriol (uE3), and hCG and to determine whether it is appropriate to take smoking status into account when screening for fetal Down syndrome. Smoking information was obtained from 23,668 pregnant women at the time of routine screening for fetal Down syndrome. Serum levels of AFP, uE3, and hCG were stratified by smoking status and compared. Individual risks for fetal Down syndrome were analyzed both before and after adjusting the hCG levels for the effect of smoking. The prevalence of Down syndrome in the study population was calculated for both smokers and non-smokers. The average AFP, uE3, and hCG levels in women who smoked cigarettes were 3% greater (95% confidence interval [CI] 2-4%), 3% less (95% CI 2-4%), and 23% less (95% CI 22-24%), respectively, compared with levels in non-smokers. At comparable maternal ages, women who smoked cigarettes were identified as being at high risk for fetal Down syndrome 40% less often than non-smokers (4.0 versus 7.1% at a risk level of 1:250). Adjusting hCG levels for smoking status reduced the overall false-positive rate from 6.4 to 6.1% (using a term risk cutoff level of 1:250). The predicted effect on detection was small (a 0.7% increase). The prevalence of Down syndrome was lower among smokers, but the difference was not statistically significant (odds ratio 0.51, 95% CI 0.15-1.5). Adjusting the serum markers used for Down syndrome screening for the effect of maternal smoking has a small effect on overall screening performance. Given the uncertainty over whether there is a lower birth prevalence among women who smoke cigarettes, such adjustment is not currently justified.
- 1 May 1993
- Vol. 81, 675-8
Cigarette smoking and levels of maternal serum alpha-fetoprotein, unconjugated estriol, and hCG: impact on Down syndrome screening.
To investigate the association between maternal cigarette smoking and serum levels of alpha-fetoprotein (AFP), unconjugated estriol (uE3), and hCG and to determine whether it is appropriate to take smoking status into account when screening for fetal Down syndrome. Smoking information was obtained from 23,668 pregnant women at the time of routine screening for fetal Down syndrome. Serum levels of AFP, uE3, and hCG were stratified by smoking status and compared. Individual risks for fetal Down syndrome were analyzed both before and after adjusting the hCG levels for the effect of smoking. The prevalence of Down syndrome in the study population was calculated for both smokers and non-smokers. The average AFP, uE3, and hCG levels in women who smoked cigarettes were 3% greater (95% confidence interval [CI] 2-4%), 3% less (95% CI 2-4%), and 23% less (95% CI 22-24%), respectively, compared with levels in non-smokers. At comparable maternal ages, women who smoked cigarettes were identified as being at high risk for fetal Down syndrome 40% less often than non-smokers (4.0 versus 7.1% at a risk level of 1:250). Adjusting hCG levels for smoking status reduced the overall false-positive rate from 6.4 to 6.1% (using a term risk cutoff level of 1:250). The predicted effect on detection was small (a 0.7% increase). The prevalence of Down syndrome was lower among smokers, but the difference was not statistically significant (odds ratio 0.51, 95% CI 0.15-1.5). Adjusting the serum markers used for Down syndrome screening for the effect of maternal smoking has a small effect on overall screening performance. Given the uncertainty over whether there is a lower birth prevalence among women who smoke cigarettes, such adjustment is not currently justified.
- 1 December 1991
- Vol. 78 (6) , 1078-80
Self-rated physical activity level during the second trimester and pregnancy outcome.
To examine the relationship between level of physical activity during pregnancy and subsequent pregnancy outcome, we asked women enrolling for maternal serum alpha-fetoprotein (MSAFP) screening in Maine during the years 1984-1988 to rate their usual physical activity level as light, moderate, or vigorous. Overall, 23,091 women were approached and 21,342 (92%) responded. Ten percent rated their physical activity level as light, 84% as moderate, and 6% as vigorous. Those who identified their physical activity level as vigorous were, on average, slightly older and more educated, and weighted less than women in the other two categories. However, there were no significant differences in the rates of low birth weight or fetal or neonatal death.
- 1 December 1991
- Vol. 78 (6) , 1078-80
Self-rated physical activity level during the second trimester and pregnancy outcome.
To examine the relationship between level of physical activity during pregnancy and subsequent pregnancy outcome, we asked women enrolling for maternal serum alpha-fetoprotein (MSAFP) screening in Maine during the years 1984-1988 to rate their usual physical activity level as light, moderate, or vigorous. Overall, 23,091 women were approached and 21,342 (92%) responded. Ten percent rated their physical activity level as light, 84% as moderate, and 6% as vigorous. Those who identified their physical activity level as vigorous were, on average, slightly older and more educated, and weighted less than women in the other two categories. However, there were no significant differences in the rates of low birth weight or fetal or neonatal death.