KHKarl G. Helmer

Karl G. Helmer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Karl G. Helmer has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • C. H. Sotak

    Departments of Biomedical Engineering and Chemistry and Biochemistry, Worcester Polytechnic Institute, Worcester, MA 01609

    1 shared publication
  • Christopher H. Sotak

    Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, Massachusetts

    1 shared publication
  • J. Wellen

    Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA 01609

    1 shared publication
  • Joseph D. Petruccelli

    Department of Mathematical Sciences, Worcester Polytechnic Institute, Worcester, Massachusetts

    1 shared publication
  • Michael R. Meiler

    Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, Massachusetts

    1 shared publication
  • P. Grigg

    Department of Physiology, University of Massachusetts Medical School, Worcester, MA 01655

    1 shared publication

Latest Publications

  • Measurement of the Spatial Redistribution of Water in Rabbit Achilles Tendon in Response to Static Tensile Loading

    by K. G. Helmer, J. Wellen, P. Grigg, C. H. Sotak

    The redistribution of water in response to static tensile loading was investigated in rabbit Achilles tendons in vitro. The distribution of water was measured along a radially oriented line, using a one-dimensional proton-density map created from fits to diffusion-weighted magnetic resonance (MR) data. Water movements were measured during application of tensile loads of 5N (N=7) and 10N (N=6). Water distribution along the line was measured before loading and up to 42 min after load application. Static loading with either 5 or 10N loads caused a steady increase in proton density in the outside edge (rim) of the tendon. The 10N load lowered the proton density in the core of the tendon, but did so in a single step that was observed when the load was applied. The 5N load caused no change in proton density in the core region. The immediate redistribution from the core was statistically significant for the 10N load, but not the 5N load application. Statistically significant within-group proton-density increases were observed in the rim after 42 min postload for all tendons irrespective of load condition. The rate of proton-density postload increase at the rim region did not depend upon load. The rate for the 5N load case was 0.010±0.002 min−1 and 0.007±0.002 min−1 in the 10N case. Thus, while generally consistent with an extrusion model, the data show other features that argue for a more complex model.


  • Comparison of the return-to-the-origin probability and the apparent diffusion coefficient of water as indicators of necrosis in RIF-1 tumors

    by Karl G. Helmer, Michael R. Meiler, Christopher H. Sotak, Joseph D. Petruccelli

    Two model‐independent measures of diffusion, the apparent diffusion coefficient (ADC) and return‐to‐the‐origin probability enhancement (R) were compared for their ability to detect tissue necrosis in RIF‐1 murine tumors. Both reflect the degree of restriction experienced by the endogenous water molecules; however, the ADC is calculated from the initial linear slope of the diffusion attenuation curve, while R is calculated from data that includes the non‐monoexponential part of the curve. In spectroscopic studies (n = 9), neither the ADC nor R showed a strong correlation with tumor volume. In imaging studies (n = 14), ADC, R, and T2 were calculated on a pixel‐by‐pixel basis. There, the mean ADC and mean R for the entire imaging slice showed reasonable correlation with necrotic tumor fraction (r2 = 0.679 and −0.665, respectively). The mean T2 value yielded a poor correlation (r2 = 0.436). Regions‐of‐interest were chosen from areas identified as either necrotic or viable and the resulting sets of ADC and R‐values were subjected to discriminant analysis to determine the identification error rate. The error was greater for R than for the ADC (P < 0.001). Therefore, in this application, the use of the non‐monoexponential part of the diffusion attenuation curve does not provide additional identification power. Magn Reson Med 49:468–478, 2003.