Reiner Hente
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Reiner Hente has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
B. Füchtmeier
Abteilung für Unfallchirurgie, Klinikum der Universität Regensburg
2 shared publicationsA. Ernstberger
Department of Traumatology, Trauma Center Regensburg, University of Regensburg, Franz-Josef-Strauss-Allee 11, D-93042 Regensburg, Germany
1 shared publicationB. Kinner
Abteilung für Unfallchirurgie, Klinikum der Universität Regensburg
1 shared publicationJ. Kampshoff
Abteilung für Unfallchirurgie, Klinikum der Universität Regensburg
1 shared publication- Jacques Cordey
Plazziel 175, CH – 7477 Filisur, Switzerland
1 shared publication M. Nerlich
Abteilung für Unfallchirurgie, Klinikum der Universität Regensburg
1 shared publication
Latest Publications
- 1 September 2004
- Published by Springer Nature in Der Unfallchirurg
- Vol. 107 (9) , 769-782
Die Versorgung dislozierter 3- und 4-Fragmentfrakturen des proximalen Humerus mit einem winkelstabilen Plattenfixateur
- 1 September 2004
- Published by Springer Nature in Der Unfallchirurg
- Vol. 107 (9) , 769-782
Die Versorgung dislozierter 3- und 4-Fragmentfrakturen des proximalen Humerus mit einem winkelstabilen Plattenfixateur
- 1 July 2004
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 22 (4) , 709-715
The influence of cyclic compression and distraction on the healing of experimental tibial fractures
Interfragmentary displacement has a main effect on callus formation in fracture healing. To test whether compressive or distractive displacements have a more pronounced effect on new bone formation, a sheep osteotomy model was created whereby the gap tissue was subjected to constant bending displacement. A diaphyseal osteotomy with a gap of 2 mm was created in 18 sheep tibiae and stabilized with a special unilateral actuator‐driven external fixator. Two experimental groups with six sheep each received either 10 or 1000 cycles evenly distributed over 24 h. The third group of six sheep served as a control group without actively induced displacement. The amount and direction of cyclic displacement was kept constant throughout the observation period, resulting in 50% compressive and 50% distractive displacement within the osteotomy gap. At sacrifice, six weeks after surgery, bending stiffness was measured and new bone formation was assessed radiologically and microradiographically. In all cycled groups, the amount of periosteal callus formation was up to 25 times greater on the compression compared to the distraction side (p < 0.001). The application of the higher number of daily cycles resulted in an up to 10‐fold greater amount of periosteal new bone formation on the compression side (p < 0.012), while the difference on the distraction side was not significant. Ten cycles applied a day were sufficient to create an abundant periosteal callus on the compression side. In the 1000 cycle group, bending stiffness revealed slightly lower values but the difference was not significant. Solid periosteal bridging of the gap was observed in two sheep in the control group, whereas bridging in the cycled groups was observed exclusively at the medullary side. In conclusion, cyclic compressive displacements were found to be superior over distractive displacements. A higher number of enforced and maintained compressive displacements enhanced periosteal callus formation but did not allow bony bridging of the gap. © 2003 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
- 1 July 2004
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 22 (4) , 709-715
The influence of cyclic compression and distraction on the healing of experimental tibial fractures
Interfragmentary displacement has a main effect on callus formation in fracture healing. To test whether compressive or distractive displacements have a more pronounced effect on new bone formation, a sheep osteotomy model was created whereby the gap tissue was subjected to constant bending displacement. A diaphyseal osteotomy with a gap of 2 mm was created in 18 sheep tibiae and stabilized with a special unilateral actuator‐driven external fixator. Two experimental groups with six sheep each received either 10 or 1000 cycles evenly distributed over 24 h. The third group of six sheep served as a control group without actively induced displacement. The amount and direction of cyclic displacement was kept constant throughout the observation period, resulting in 50% compressive and 50% distractive displacement within the osteotomy gap. At sacrifice, six weeks after surgery, bending stiffness was measured and new bone formation was assessed radiologically and microradiographically. In all cycled groups, the amount of periosteal callus formation was up to 25 times greater on the compression compared to the distraction side (p < 0.001). The application of the higher number of daily cycles resulted in an up to 10‐fold greater amount of periosteal new bone formation on the compression side (p < 0.012), while the difference on the distraction side was not significant. Ten cycles applied a day were sufficient to create an abundant periosteal callus on the compression side. In the 1000 cycle group, bending stiffness revealed slightly lower values but the difference was not significant. Solid periosteal bridging of the gap was observed in two sheep in the control group, whereas bridging in the cycled groups was observed exclusively at the medullary side. In conclusion, cyclic compressive displacements were found to be superior over distractive displacements. A higher number of enforced and maintained compressive displacements enhanced periosteal callus formation but did not allow bony bridging of the gap. © 2003 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
- Open Access
- 28 March 2003
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 2 (1) , 8
In vivo measurement of bending stiffness in fracture healing
Measurement of the bending stiffness a healing fracture represents a valid variable in the assessment of fracture healing. However, currently available methods typically have high measurement errors, even for mild pin loosening. Furthermore, these methods cannot provide actual values of bending stiffness, which precludes comparisons among individual fractures. Thus, even today, little information is available with regards to the fracture healing pattern with respect to actual values of bending stiffness. Our goals were, therefore: to develop a measurement device that would allow accurate and sensitive measurement of bending stiffness, even in the presence of mild pin loosening; to describe the course of healing in individual fractures; and help to evaluate whether the individual pattern of bending stiffness can be predicted at an early stage of healing. A new measurement device has been developed to precisely measure the bending stiffness of the healing fracture by simulating four-point-bending. The system was calibrated on aluminum models and intact tibiae. The influence of pin loosening on measurement error was evaluated. The system was tested at weekly intervals in an animal experiment to determine the actual bending stiffness of the fracture. Transverse fractures were created in the right tibia of twelve sheep, and then stabilized with an external fixator. At ten weeks, bending stiffness of the tibiae were determined in a four-point-bending test device to validate the in-vivo-measurement data. In-vivo bending stiffness can be measured accurately and sensitive, even in the early phase of callus healing. Up to a bending stiffness of 10 Nm/degree, measurement error was below 3.4% for one pin loose, and below 29.3% for four pins loose, respectively. Measurement of stiffness data over time revealed a significant logarithmic increase between the third and seventh weeks, whereby the logarithmic rate of change among sheep was similar, but started from different levels. Comparative measurements showed that early individual changes between the third and fourth weeks can be used as a predictor of bending stiffness at seven weeks (r = 0.928) and at ten weeks (r = 0.710). Bending stiffness can be measured precisely, with less error in the case of pin loosening. Prediction of the future healing course of the individual fracture can be assessed by changes from the third to the fourth week, with differences in stiffness levels. Therefore, the initial status of the fracture seems to have a high impact on the individual healing course.
- 28 March 2003
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 2 (1) , 8
Open AccessIn vivo measurement of bending stiffness in fracture healing
Measurement of the bending stiffness a healing fracture represents a valid variable in the assessment of fracture healing. However, currently available methods typically have high measurement errors, even for mild pin loosening. Furthermore, these methods cannot provide actual values of bending stiffness, which precludes comparisons among individual fractures. Thus, even today, little information is available with regards to the fracture healing pattern with respect to actual values of bending stiffness. Our goals were, therefore: to develop a measurement device that would allow accurate and sensitive measurement of bending stiffness, even in the presence of mild pin loosening; to describe the course of healing in individual fractures; and help to evaluate whether the individual pattern of bending stiffness can be predicted at an early stage of healing. A new measurement device has been developed to precisely measure the bending stiffness of the healing fracture by simulating four-point-bending. The system was calibrated on aluminum models and intact tibiae. The influence of pin loosening on measurement error was evaluated. The system was tested at weekly intervals in an animal experiment to determine the actual bending stiffness of the fracture. Transverse fractures were created in the right tibia of twelve sheep, and then stabilized with an external fixator. At ten weeks, bending stiffness of the tibiae were determined in a four-point-bending test device to validate the in-vivo-measurement data. In-vivo bending stiffness can be measured accurately and sensitive, even in the early phase of callus healing. Up to a bending stiffness of 10 Nm/degree, measurement error was below 3.4% for one pin loose, and below 29.3% for four pins loose, respectively. Measurement of stiffness data over time revealed a significant logarithmic increase between the third and seventh weeks, whereby the logarithmic rate of change among sheep was similar, but started from different levels. Comparative measurements showed that early individual changes between the third and fourth weeks can be used as a predictor of bending stiffness at seven weeks (r = 0.928) and at ten weeks (r = 0.710). Bending stiffness can be measured precisely, with less error in the case of pin loosening. Prediction of the future healing course of the individual fracture can be assessed by changes from the third to the fourth week, with differences in stiffness levels. Therefore, the initial status of the fracture seems to have a high impact on the individual healing course.