Michael Schartl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael Schartl has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Wolfgang Bocksch
Charité-Campus Virchow-Klinikum, Universitatsmedizin Berlin, Berlin, Germany
6 shared publications S Beckmann
Abteilung für Kardiologie und Angiologie, Virchow-Klinikum der Medizinischen Fakultät, Humboldt-Universität zu Berlin
4 shared publicationsH Paeprer
2 shared publicationsS Dreysse
2 shared publicationsWolfgang Bocksch
2 shared publicationsDietmar H. Koschyk
From the Universitaetsklinikum Charité, Campus Virchow, and German Heart Institute Berlin (M.S., W.B.), Krankenhaus am Urban (S.B.), and Universitaetsklinikum Charité Campus Buch und Franz-Volhard-Klinik (M.G.), Berlin; Universitaetsklinikum Hamburg-Eppendorf (D.H.K.), Hamburg; Klinikum der Stadt Mannheim (W.V.), Mannheim; Medizinische Klinik der Eberhard-Karls Universitaet Tuebingen (K.R.K.), Tuebingen; Medizinische Klinik der Ruprecht-Karls-Universitaet Heidelberg (J.K.), Heidelberg; and...
1 shared publication
Latest Publications
- 1 February 2004
- Published by Wolters Kluwer Health in Coronary Artery Disease
- Vol. 15 (1) , 45-51
Effects of lipid-lowering therapy on coronary artery remodeling
Although lipid-lowering therapy affects the luminal size of atherosclerotic coronary arteries the role of vascular remodeling has not been systematically studied. Serial three-dimensional volumetric intravascular ultrasound (IVUS) was used to study remodeling, which was defined as changes in arterial size independent of or dependent on changes in plaque size. Using an automated contour detection algorithm, a 1 mm segment of a moderate atherosclerotic lesion at the site of the maximal plaque volume at baseline was analysed. After 12 months the relationship between the absolute change in vessel volume and plaque volume was calculated in 99 patients. There was a significant relationship between changes in plaque and vessel volume, independent of plaque progression or plaque regression (decrease in plaque size, r=0.60, P<0.0001 and increase in plaque size, r=0.49, P<0.0008, respectively; the slopes of the regression equation were 1.03 and 0.80). By means of an analysis of covariance we tested whether the regression slopes were equal between groups of patients as defined by the low-density lipoprotein-cholesterol (LDL-c) level achieved with lipid-lowering therapy. Only patients with plaque progression and a LDL-c level 100 mg/dl (–0.14 compared with 1.14, P=0.003 ), indicating diminished coronary remodeling. Serial volumetric IVUS confirms the existence of both positive and negative remodeling in relation to an increase and decrease in plaque volume. It has been shown that the outward remodeling process is diminished in patients with plaque progression and intensive lipid-lowering therapy.
- 1 February 2004
- Published by Wolters Kluwer Health in Coronary Artery Disease
- Vol. 15 (1) , 45-51
Effects of lipid-lowering therapy on coronary artery remodeling
Although lipid-lowering therapy affects the luminal size of atherosclerotic coronary arteries the role of vascular remodeling has not been systematically studied. Serial three-dimensional volumetric intravascular ultrasound (IVUS) was used to study remodeling, which was defined as changes in arterial size independent of or dependent on changes in plaque size. Using an automated contour detection algorithm, a 1 mm segment of a moderate atherosclerotic lesion at the site of the maximal plaque volume at baseline was analysed. After 12 months the relationship between the absolute change in vessel volume and plaque volume was calculated in 99 patients. There was a significant relationship between changes in plaque and vessel volume, independent of plaque progression or plaque regression (decrease in plaque size, r=0.60, P<0.0001 and increase in plaque size, r=0.49, P<0.0008, respectively; the slopes of the regression equation were 1.03 and 0.80). By means of an analysis of covariance we tested whether the regression slopes were equal between groups of patients as defined by the low-density lipoprotein-cholesterol (LDL-c) level achieved with lipid-lowering therapy. Only patients with plaque progression and a LDL-c level 100 mg/dl (–0.14 compared with 1.14, P=0.003 ), indicating diminished coronary remodeling. Serial volumetric IVUS confirms the existence of both positive and negative remodeling in relation to an increase and decrease in plaque volume. It has been shown that the outward remodeling process is diminished in patients with plaque progression and intensive lipid-lowering therapy.
- 24 July 2001
- Published by Wolters Kluwer Health in Circulation
- Vol. 104 (4) , 387-392
Use of Intravascular Ultrasound to Compare Effects of Different Strategies of Lipid-Lowering Therapy on Plaque Volume and Composition in Patients With Coronary Artery Disease
Background We studied whether lipid-lowering therapy with atorvastatin (target LDL cholesterol [LDL-C] Methods and Results This study was a 12-month, open-label, randomized, multicenter trial, which used serial 3D intracoronary ultrasound to calculate plaque volume and plaque echogenicity. After transcatheter therapy, 131 patients were randomized (atorvastatin n=65, usual care n=66). The target plaque had to be a minor lesion (ie, a diameter stenosis of 3 , atorvastatin 1.2±30.4 mm 3 ; P =0.191). The hyperechogenicity index of the plaque increased to a larger extent for the atorvastatin group than for the usual care group, with a significant treatment effect for the percent change (atorvastatin 42.2%, usual care 10.1%; P =0.021). Conclusions One year of lipid-lowering therapy to <100 mg/dL LDL-C most likely led to a slowdown of plaque growth of minor lesions. The significantly larger increase in plaque hyperechogenicity is most likely due to a change in plaque composition.
- 24 July 2001
- Published by Wolters Kluwer Health in Circulation
- Vol. 104 (4) , 387-392
Use of Intravascular Ultrasound to Compare Effects of Different Strategies of Lipid-Lowering Therapy on Plaque Volume and Composition in Patients With Coronary Artery Disease
Background We studied whether lipid-lowering therapy with atorvastatin (target LDL cholesterol [LDL-C] Methods and Results This study was a 12-month, open-label, randomized, multicenter trial, which used serial 3D intracoronary ultrasound to calculate plaque volume and plaque echogenicity. After transcatheter therapy, 131 patients were randomized (atorvastatin n=65, usual care n=66). The target plaque had to be a minor lesion (ie, a diameter stenosis of 3 , atorvastatin 1.2±30.4 mm 3 ; P =0.191). The hyperechogenicity index of the plaque increased to a larger extent for the atorvastatin group than for the usual care group, with a significant treatment effect for the percent change (atorvastatin 42.2%, usual care 10.1%; P =0.021). Conclusions One year of lipid-lowering therapy to <100 mg/dL LDL-C most likely led to a slowdown of plaque growth of minor lesions. The significantly larger increase in plaque hyperechogenicity is most likely due to a change in plaque composition.
- 1 February 1996
- Vol. 21 (1) , 65
-Practical implementation of stress echocardiography--what should be monitored?-.
- 1 February 1996
- Vol. 21 (1) , 65
-Practical implementation of stress echocardiography--what should be monitored?-.
- 1 September 1994
- Vol. 5 (9) , 727-35
Intravascular ultrasound imaging in patients with acute myocardial infarction: comparison with chronic stable angina pectoris.
Myocardial infarction is the result of acute thrombotic occlusion of a coronary artery, most likely secondary to rupture of an atherosclerotic plaque. Intracoronary ultrasonic (ICUS) examinations were performed in patients with acute myocardial infarction (AMI) in order to describe intraluminal ultrasonic findings at the site of acute coronary occlusion. Coronary angiography and ICUS studies were performed consecutively within 6 h of the onset of chest pain in 30 patients with AMI prior to percutaneous transluminal coronary angioplasty (PTCA). The control group consisted of 30 patients with chronic stable angina pectoris (SAP). Following angiographic documentation of a proximal stenosis or occlusion, a 3.5 or 4.8 F mechanical ultrasound catheter (20 MHz) was advanced successfully through the lesion in 25 of 30 (83%) patients with AMI and in 15 of 30 (50%) patients with SAP (P < 0.01). Intracoronary ultrasound permitted differentiation between pulsatile, low-echogenic intraluminal material suggesting thrombus and mural highly echogenic atherosclerotic plaque in 22 of 25 (88%) patients with AMI. A negative imprint of the ICUS catheter was documented within the low-echogenic material in 17 of 25 (68%) patients with AMI. Low-echogenic intraluminal material was found in 18 of 25 (72%) segments proximal and in 12 of 25 (48%) segments distal to the highly echogenic plaque, indicating prestenotic and post-stenotic thrombus in AMI. The plaque appeared eccentric in 22 of 25 (88%) patients with AMI. In comparison, stenotic lesions in chronic SAP patients were less frequently eccentric (5/15, 33%, P < 0.01) and contained a higher proportion of pure highly echogenic material (12/15, 80%). Cross-sectional area stenosis due to highly echogenic plaque averaged 52 +/- 13% in AMI and 82 +/- 3% in SAP (P < 0.01). Calcification of plaque was evident in 21 of 25 patients with AMI (SAP 12/15, 80%, NS). The surface of the plaque was rough in 13 of 25 (52%) AMI patients (SAP 4/15, 27%, P < 0.05). Fissures were detected in only seven (28%) patients and dissection was observed in two (8%) cases. The low incidence might be a result of the limited resolution of the ICUS system. This study demonstrates that ICUS with 4.8 or 3.5 F catheters is feasible and safe in selected patients with AMI, and adds little to the overall duration of the angioplasty procedure. The identification and demarcation of atherosclerotic plaque provided by ICUS could prove valuable in guiding PTCA, in deciding on appropriate therapy, and in acute and long-term follow-up of AMI patients.
- 1 September 1994
- Vol. 5 (9) , 727-35
Intravascular ultrasound imaging in patients with acute myocardial infarction: comparison with chronic stable angina pectoris.
Myocardial infarction is the result of acute thrombotic occlusion of a coronary artery, most likely secondary to rupture of an atherosclerotic plaque. Intracoronary ultrasonic (ICUS) examinations were performed in patients with acute myocardial infarction (AMI) in order to describe intraluminal ultrasonic findings at the site of acute coronary occlusion. Coronary angiography and ICUS studies were performed consecutively within 6 h of the onset of chest pain in 30 patients with AMI prior to percutaneous transluminal coronary angioplasty (PTCA). The control group consisted of 30 patients with chronic stable angina pectoris (SAP). Following angiographic documentation of a proximal stenosis or occlusion, a 3.5 or 4.8 F mechanical ultrasound catheter (20 MHz) was advanced successfully through the lesion in 25 of 30 (83%) patients with AMI and in 15 of 30 (50%) patients with SAP (P < 0.01). Intracoronary ultrasound permitted differentiation between pulsatile, low-echogenic intraluminal material suggesting thrombus and mural highly echogenic atherosclerotic plaque in 22 of 25 (88%) patients with AMI. A negative imprint of the ICUS catheter was documented within the low-echogenic material in 17 of 25 (68%) patients with AMI. Low-echogenic intraluminal material was found in 18 of 25 (72%) segments proximal and in 12 of 25 (48%) segments distal to the highly echogenic plaque, indicating prestenotic and post-stenotic thrombus in AMI. The plaque appeared eccentric in 22 of 25 (88%) patients with AMI. In comparison, stenotic lesions in chronic SAP patients were less frequently eccentric (5/15, 33%, P < 0.01) and contained a higher proportion of pure highly echogenic material (12/15, 80%). Cross-sectional area stenosis due to highly echogenic plaque averaged 52 +/- 13% in AMI and 82 +/- 3% in SAP (P < 0.01). Calcification of plaque was evident in 21 of 25 patients with AMI (SAP 12/15, 80%, NS). The surface of the plaque was rough in 13 of 25 (52%) AMI patients (SAP 4/15, 27%, P < 0.05). Fissures were detected in only seven (28%) patients and dissection was observed in two (8%) cases. The low incidence might be a result of the limited resolution of the ICUS system. This study demonstrates that ICUS with 4.8 or 3.5 F catheters is feasible and safe in selected patients with AMI, and adds little to the overall duration of the angioplasty procedure. The identification and demarcation of atherosclerotic plaque provided by ICUS could prove valuable in guiding PTCA, in deciding on appropriate therapy, and in acute and long-term follow-up of AMI patients.
- 1 August 1994
- Vol. 83 (8) , 531-47
[Stress echocardiography--an evaluation of current status].
Exercise echocardiography, a versatile, noninvasive diagnostic test of left ventricular wall motion performed at rest and under induced stress, enables the cardiologist to detect and assess coronary artery disease. Stress-induced ischemia is thereby expressed as left ventricular regional wall motion abnormality. By using various physical (bicycle or treadmill exercise) and pharmacological (dipyridamole, dobutamine, adenosine) stress inducers, the test provides information about the localization and extent of coronary artery disease in addition to detecting stress-induced coronary insufficiency. As regards diagnostic accuracy in detecting coronary artery disease, stress echocardiography is superior to exercise electrocardiography and, according to the available data, it is comparable to perfusion scintigraphic testing. Studies have demonstrated the clinical value of stress echocardiography in detecting residual stenosis after angioplasty, for diagnosing bypass dysfunction after heart surgery, for preoperative risk assessment in noncardiac surgeries, and for obtaining prognostic information, e.g., after myocardial infarction. Preliminary studies have shown that pharmacological exercise echocardiography is able to identify viable myocardium in the early phases after acute myocardial infarction. Furthermore, it is able to predict the functional success of revascularization in chronic regional left ventricular dysfunction. In addition to the wide range of diagnostic possibilities in coronary artery disease, other notable applications include stress testing for assessment of global left ventricular pump function in patients with aortic regurgitation or cardiomyopathy.
- 1 August 1994
- Vol. 83 (8) , 531-47
[Stress echocardiography--an evaluation of current status].
Exercise echocardiography, a versatile, noninvasive diagnostic test of left ventricular wall motion performed at rest and under induced stress, enables the cardiologist to detect and assess coronary artery disease. Stress-induced ischemia is thereby expressed as left ventricular regional wall motion abnormality. By using various physical (bicycle or treadmill exercise) and pharmacological (dipyridamole, dobutamine, adenosine) stress inducers, the test provides information about the localization and extent of coronary artery disease in addition to detecting stress-induced coronary insufficiency. As regards diagnostic accuracy in detecting coronary artery disease, stress echocardiography is superior to exercise electrocardiography and, according to the available data, it is comparable to perfusion scintigraphic testing. Studies have demonstrated the clinical value of stress echocardiography in detecting residual stenosis after angioplasty, for diagnosing bypass dysfunction after heart surgery, for preoperative risk assessment in noncardiac surgeries, and for obtaining prognostic information, e.g., after myocardial infarction. Preliminary studies have shown that pharmacological exercise echocardiography is able to identify viable myocardium in the early phases after acute myocardial infarction. Furthermore, it is able to predict the functional success of revascularization in chronic regional left ventricular dysfunction. In addition to the wide range of diagnostic possibilities in coronary artery disease, other notable applications include stress testing for assessment of global left ventricular pump function in patients with aortic regurgitation or cardiomyopathy.
- 1 July 1994
- Vol. 12 (4) , S37-42
Remodeling of myocardium and arteries by chronic angiotensin converting enzyme inhibition in hypertensive patients.
To investigate changes in left ventricular hypertrophy and diastolic function in hypertensive patients treated with an angiotensin converting enzyme (ACE) inhibitor. Structural and functional changes in the heart and iliac artery were studied by echocardiography and intraluminal ultrasound in 15 hypertensive patients following 6 months of treatment with the ACE inhibitor quinapril at 10-40 mg/day. Systolic/diastolic blood pressure was reduced from 156/100 mmHg to 128/82 mmHg within 2 months and remained stable during the next 4 months of the study. The left ventricular mass index was significantly reduced from 174 +/- 86 to 161 +/- 75 g/m2 (-7.4%, P < 0.05). The reduction in left ventricular hypertrophy was associated with a trend towards an improvement in diastolic function, but left ventricular systolic function did not change. There was a 3.9% increase in iliac lumen area and a significant decrease of 10.7% (P < 0.05) in the ratio between the intimal-medial and lumen area, which represents a decrease in wall thickness. A key result was a statistically significant decrease in pulse-wave velocity, from 13.7 +/- 2.6 to 12.1 +/- 2.0 m/s, and in the modulus of elasticity, from 20.5 +/- 7.2 to 15.8 +/- 5.6 x 10(4) N/m2 (P < 0.05). The present study demonstrates that 6 months of treatment with an ACE inhibitor induced a significant regression in left ventricular hypertrophy and a reduction in wall thickness. In addition, the results indicate that chronic ACE inhibition can decrease the stiffness of large elastic arteries independently of a reduction in blood pressure.
- 1 July 1994
- Vol. 12 (4) , S37-42
Remodeling of myocardium and arteries by chronic angiotensin converting enzyme inhibition in hypertensive patients.
To investigate changes in left ventricular hypertrophy and diastolic function in hypertensive patients treated with an angiotensin converting enzyme (ACE) inhibitor. Structural and functional changes in the heart and iliac artery were studied by echocardiography and intraluminal ultrasound in 15 hypertensive patients following 6 months of treatment with the ACE inhibitor quinapril at 10-40 mg/day. Systolic/diastolic blood pressure was reduced from 156/100 mmHg to 128/82 mmHg within 2 months and remained stable during the next 4 months of the study. The left ventricular mass index was significantly reduced from 174 +/- 86 to 161 +/- 75 g/m2 (-7.4%, P < 0.05). The reduction in left ventricular hypertrophy was associated with a trend towards an improvement in diastolic function, but left ventricular systolic function did not change. There was a 3.9% increase in iliac lumen area and a significant decrease of 10.7% (P < 0.05) in the ratio between the intimal-medial and lumen area, which represents a decrease in wall thickness. A key result was a statistically significant decrease in pulse-wave velocity, from 13.7 +/- 2.6 to 12.1 +/- 2.0 m/s, and in the modulus of elasticity, from 20.5 +/- 7.2 to 15.8 +/- 5.6 x 10(4) N/m2 (P < 0.05). The present study demonstrates that 6 months of treatment with an ACE inhibitor induced a significant regression in left ventricular hypertrophy and a reduction in wall thickness. In addition, the results indicate that chronic ACE inhibition can decrease the stiffness of large elastic arteries independently of a reduction in blood pressure.
- 1 May 1993
- Vol. 82 (5) , 317-23
[Stress echocardiography: evaluation of left ventricular function after administration of the transpulmonary echo contrast medium SHU 508 A].
Stress echocardiography has recently gained increased importance as a method for assessment of left ventricular function. However, suboptimal image quality in some patients may limit use of this technique. In the present study, 10 patients with moderate image quality in the resting echocardiograms (apical 4-chamberview) were reinvestigated after administration of the intravenous transpulmonary saccharide-based left heart contrast agent SHU 508 A. Duration of contrast enhancement in the left ventricle determined by visual assessment was 135 s (SEE +/- 39) at rest and 112 s (+/- 24) during maximum exercise. On a scale ranging from O (no contrast) to 4 (excessively strong contrast) enhancement averaged 2.5 at rest and during exercise. The left ventricle was divided into three segments (septum, apex, lateral wall) and delineation of the endocardial border was assessed. Detection of the border improved significantly after contrast administration, especially at the lateral wall. Despite better visual assessment of the endocardial border, there was no improvement in automatic or semi-automatic contour recognition. No clinically significant side-effects were observed. Three patients reported a sensation of warmth at the injection site. In conclusion, intravenous administration of SHU 508 A improves visual detection of the left ventricular endocardial border in patients with suboptimal image quality and helps to achieve acceptable diagnostic accuracy with stress echocardiography in these patients.
- 1 May 1993
- Vol. 82 (5) , 317-23
[Stress echocardiography: evaluation of left ventricular function after administration of the transpulmonary echo contrast medium SHU 508 A].
Stress echocardiography has recently gained increased importance as a method for assessment of left ventricular function. However, suboptimal image quality in some patients may limit use of this technique. In the present study, 10 patients with moderate image quality in the resting echocardiograms (apical 4-chamberview) were reinvestigated after administration of the intravenous transpulmonary saccharide-based left heart contrast agent SHU 508 A. Duration of contrast enhancement in the left ventricle determined by visual assessment was 135 s (SEE +/- 39) at rest and 112 s (+/- 24) during maximum exercise. On a scale ranging from O (no contrast) to 4 (excessively strong contrast) enhancement averaged 2.5 at rest and during exercise. The left ventricle was divided into three segments (septum, apex, lateral wall) and delineation of the endocardial border was assessed. Detection of the border improved significantly after contrast administration, especially at the lateral wall. Despite better visual assessment of the endocardial border, there was no improvement in automatic or semi-automatic contour recognition. No clinically significant side-effects were observed. Three patients reported a sensation of warmth at the injection site. In conclusion, intravenous administration of SHU 508 A improves visual detection of the left ventricular endocardial border in patients with suboptimal image quality and helps to achieve acceptable diagnostic accuracy with stress echocardiography in these patients.
- 1 January 1991
- Vol. 32, 107-12
[Intraluminal ultrasound diagnosis in assessment of arteriosclerotic vascular changes].
- 1 January 1991
- Vol. 32, 107-12
[Intraluminal ultrasound diagnosis in assessment of arteriosclerotic vascular changes].