Gerald L. Wolf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gerald L. Wolf has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
George W. Sidebotham
Associate Professor of Chemical Engineering, The Cooper Union for the Advancement of Science and Art
2 shared publicationsGeorge W Sidebotham
1 shared publicationJackson L Lazard
1 shared publicationJackson L. P. Lazard
Fellow, Critical Care Medicine/Anesthesiology
1 shared publicationJean Charchaflieh
1 shared publicationJean G. Charchaflieh
Assistant Professor of Anesthesiology, State University of New York, Downstate Medical Center
1 shared publication
Latest Publications
- 1 May 2004
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 100 (5) , 1167-1171
Laser Ignition of Surgical Drape Materials in Air, 50% Oxygen, and 95% Oxygen
Background: Operating room fires fueled by surgical drapes and ignited by high-energy surgical tools in air and oxygen-enriched atmospheres continue to occur. Methods: The authors examined the time to ignition of huck towels and three commonly used surgical drape materials in air, 50% oxygen, and 95% oxygen using a carbon dioxide surgical laser as an ignition source. In addition, a phenol-polymer fabric was tested. Results: In air, polypropylene and phenol polymer do not ignite. For polypropylene, the laser instantly vaporized a hole, and therefore, interaction between the laser and material ceased. When tested in combination with another material, the polypropylene time to ignition assumed the behavior of the material with which it was combined. For phenol polymer, the laser did not penetrate the material. Huck towels, cotton-polyester, and non-woven cellulose-polyester ignited in air with decreasing times to ignition. All tested materials ignited in 50% and 95% oxygen. Conclusion: The results of this study reveal that with increasing oxygen concentration, the time to ignition becomes shorter, and the consequences become more severe. The possibility exists for manufacturers to develop drape materials that are safer than existing materials.
- 1 May 2004
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 100 (5) , 1167-1171
Laser Ignition of Surgical Drape Materials in Air, 50% Oxygen, and 95% Oxygen
Background: Operating room fires fueled by surgical drapes and ignited by high-energy surgical tools in air and oxygen-enriched atmospheres continue to occur. Methods: The authors examined the time to ignition of huck towels and three commonly used surgical drape materials in air, 50% oxygen, and 95% oxygen using a carbon dioxide surgical laser as an ignition source. In addition, a phenol-polymer fabric was tested. Results: In air, polypropylene and phenol polymer do not ignite. For polypropylene, the laser instantly vaporized a hole, and therefore, interaction between the laser and material ceased. When tested in combination with another material, the polypropylene time to ignition assumed the behavior of the material with which it was combined. For phenol polymer, the laser did not penetrate the material. Huck towels, cotton-polyester, and non-woven cellulose-polyester ignited in air with decreasing times to ignition. All tested materials ignited in 50% and 95% oxygen. Conclusion: The results of this study reveal that with increasing oxygen concentration, the time to ignition becomes shorter, and the consequences become more severe. The possibility exists for manufacturers to develop drape materials that are safer than existing materials.
- Open Access
- 1 September 2001
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 2001 (3) , B24
Surgical Drape Combustion in FIO2=0.21, FIO2=0.50 and FIO2=0.95
- 1 September 2001
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 2001 (3) , B24
Open AccessSurgical Drape Combustion in FIO2=0.21, FIO2=0.50 and FIO2=0.95
- 1 July 1994
- Published by Wiley in The Laryngoscope
- Vol. 104 (7) , 874-879
Intraluminal flame spread in tracheal tubes
Intraluminal combustion in polyvinyl chloride tracheal tubes was investigated. Two flame types were observed: intraluminal and downstream. The flame-spread velocity, burning rate, and equivalence ratio of the intraluminal flame were determined. The products of the intraluminal flame were analyzed, revealing compounds capable of further combustion. Below a certain oxidant flow rate, the tubes do not ignite. At low flow rates that support a flame, the burning rate is minimal and the equivalence ratio reveals no fuel available for the downstream flame, suggesting that ignition of tracheal tubes is least likely in the absence of intraluminal flow. We conclude that the downstream flame is the flame type that is most dangerous and that the intraluminal flame is the generator of fuel and ignition energy for the downstream flame.
- 1 July 1994
- Published by Wiley in The Laryngoscope
- Vol. 104 (7) , 874-879
Intraluminal flame spread in tracheal tubes
Intraluminal combustion in polyvinyl chloride tracheal tubes was investigated. Two flame types were observed: intraluminal and downstream. The flame-spread velocity, burning rate, and equivalence ratio of the intraluminal flame were determined. The products of the intraluminal flame were analyzed, revealing compounds capable of further combustion. Below a certain oxidant flow rate, the tubes do not ignite. At low flow rates that support a flame, the burning rate is minimal and the equivalence ratio reveals no fuel available for the downstream flame, suggesting that ignition of tracheal tubes is least likely in the absence of intraluminal flow. We conclude that the downstream flame is the flame type that is most dangerous and that the intraluminal flame is the generator of fuel and ignition energy for the downstream flame.