Herbert A. Reitsamer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Herbert A. Reitsamer has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Jeffrey W Kiel
2 shared publicationsClaudia Zawinka
Clinical Pharmacology, University of Vienna Medical School, Vienna, Austria
1 shared publicationHans-Peter Groiss
1 shared publicationJeffrey W. Kiel
Department of Ophthalmology, University of Texas Health Science Center, San Antonio, Texas
1 shared publicationManuela Branka
From the Departments of Physiology, and
1 shared publicationMelchior Franz
1 shared publication
Latest Publications
- 1 March 2004
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 45 (3) , 900-905
Dopaminergic Vasodilation in the Choroidal Circulation by D1/D5 Receptor Activation
Purpose. To test whether exogenous dopamine can cause choroidal vasodilation and to identify the mediating receptors in anesthetized rabbits. methods. Mean arterial pressure (MAP), intraocular pressure (IOP), and orbital venous pressure (OVP) were measured by direct cannulation of the central ear artery, the vitreous, and the orbital venous sinus, respectively. Laser Doppler flowmetry was used to measure choroidal blood flow (ChorBF) while MAP was manipulated mechanically with occluders on the aorta and vena cava, thus changing perfusion pressure (PP) over a wide range. In the first group of animals (n = 11), pressure–flow (PF) relationships were performed at control and in response to 40 μg/kg per minute intravenous (IV) dopamine (D40) and D40+SCH-23390 (0.5 mg/kg, bolus injection IV). In the second group of animals (n = 6), PF relationships were recorded at control and during infusion of SKF-38393 (80 μg/kg per minute). results. D40 lowered IOP and caused an upward shift in the choroidal PF relationship, which was blocked by the D1/D5 antagonist SCH-23390 suggesting the involvement of the dopamine D1/D5 receptors. Stimulation of the D1/D5 receptors by infusion of the selective agonist SKF-38393 also lowered IOP and caused an upward shift in the PF relationship. Dopamine and SKF-38393 tended to decrease OVP, but the effect was not significant. conclusions. Dopamine can cause choroidal vasodilation in anesthetized rabbits. Because SCH-23390 was able to block the response and SKF-38393 caused a similar vasodilation, we conclude that the vasodilation is caused by a D1/D5-receptor–mediated mechanism.
- 1 March 2004
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 45 (3) , 900-905
Dopaminergic Vasodilation in the Choroidal Circulation by D1/D5 Receptor Activation
Purpose. To test whether exogenous dopamine can cause choroidal vasodilation and to identify the mediating receptors in anesthetized rabbits. methods. Mean arterial pressure (MAP), intraocular pressure (IOP), and orbital venous pressure (OVP) were measured by direct cannulation of the central ear artery, the vitreous, and the orbital venous sinus, respectively. Laser Doppler flowmetry was used to measure choroidal blood flow (ChorBF) while MAP was manipulated mechanically with occluders on the aorta and vena cava, thus changing perfusion pressure (PP) over a wide range. In the first group of animals (n = 11), pressure–flow (PF) relationships were performed at control and in response to 40 μg/kg per minute intravenous (IV) dopamine (D40) and D40+SCH-23390 (0.5 mg/kg, bolus injection IV). In the second group of animals (n = 6), PF relationships were recorded at control and during infusion of SKF-38393 (80 μg/kg per minute). results. D40 lowered IOP and caused an upward shift in the choroidal PF relationship, which was blocked by the D1/D5 antagonist SCH-23390 suggesting the involvement of the dopamine D1/D5 receptors. Stimulation of the D1/D5 receptors by infusion of the selective agonist SKF-38393 also lowered IOP and caused an upward shift in the PF relationship. Dopamine and SKF-38393 tended to decrease OVP, but the effect was not significant. conclusions. Dopamine can cause choroidal vasodilation in anesthetized rabbits. Because SCH-23390 was able to block the response and SKF-38393 caused a similar vasodilation, we conclude that the vasodilation is caused by a D1/D5-receptor–mediated mechanism.
- 1 September 2003
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 44 (9) , 3967-3971
Relationship between Ciliary Blood Flow and Aqueous Production in Rabbits
Purpose. To determine the relationship between ciliary blood flow and aqueous flow by changing the mean arterial pressure (MAP) mechanically under controlled conditions in an animal model. methods. In anesthetized rabbits, MAP and intraocular pressure (IOP) were measured by direct cannulation. MAP was controlled with occluders placed on the aorta and vena cava. In group 1 (n = 22), aqueous flow was measured by fluorophotometry. In group 2 (n = 21), ciliary blood flow was measured by laser Doppler flowmetry. In separate subgroups, measurements were made for 60 minutes at the control MAP of 70 mm Hg and for an additional 60 minutes at target MAPs of 80, 55, or 40 mm Hg. results. The target MAPs achieved perfusion pressures (MAP − IOP) of 33.6 ± 1.0, 43.5 ± 0.7, 51.9 ± 0.6, and 65.2 ± 0.9 mm Hg. Ciliary blood flow was unaffected by increased perfusion pressure, but decreased progressively as perfusion pressure was lowered. Aqueous flow decreased only at the lowest perfusion pressure. conclusions. Under control conditions in anesthetized rabbits, aqueous production is independent of ciliary blood flow until ciliary blood flow declines below 74% of control. At ciliary blood flow below this critical level, aqueous production is blood flow dependent.
- 1 September 2003
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 44 (9) , 3967-3971
Relationship between Ciliary Blood Flow and Aqueous Production in Rabbits
Purpose. To determine the relationship between ciliary blood flow and aqueous flow by changing the mean arterial pressure (MAP) mechanically under controlled conditions in an animal model. methods. In anesthetized rabbits, MAP and intraocular pressure (IOP) were measured by direct cannulation. MAP was controlled with occluders placed on the aorta and vena cava. In group 1 (n = 22), aqueous flow was measured by fluorophotometry. In group 2 (n = 21), ciliary blood flow was measured by laser Doppler flowmetry. In separate subgroups, measurements were made for 60 minutes at the control MAP of 70 mm Hg and for an additional 60 minutes at target MAPs of 80, 55, or 40 mm Hg. results. The target MAPs achieved perfusion pressures (MAP − IOP) of 33.6 ± 1.0, 43.5 ± 0.7, 51.9 ± 0.6, and 65.2 ± 0.9 mm Hg. Ciliary blood flow was unaffected by increased perfusion pressure, but decreased progressively as perfusion pressure was lowered. Aqueous flow decreased only at the lowest perfusion pressure. conclusions. Under control conditions in anesthetized rabbits, aqueous production is independent of ciliary blood flow until ciliary blood flow declines below 74% of control. At ciliary blood flow below this critical level, aqueous production is blood flow dependent.
- 1 December 2002
- Vol. 43 (12) , 3728-34
A rabbit model to study orbital venous pressure, intraocular pressure, and ocular hemodynamics simultaneously.
To measure orbital venous pressure (OVP) and determine the effects of changes in mean arterial pressure (MAP) on OVP, intraocular pressure (IOP), episcleral venous pressure (EVP), and ciliary and choroidal blood flows. The experiments were performed in anesthetized rabbits. In all animals, MAP, IOP, and OVP were measured by direct cannulation of the central ear artery, the vitreous, and the orbital venous sinus, respectively. Laser Doppler flowmetry was used to measure choroidal blood flow in one group, and ciliary blood flow in a second group. A servonull micropressure system was used to measure EVP in a third group. The protocol for all three groups entailed varying MAP mechanically with occluders on the aorta and vena cava. The OVP and IOP relationship correlated linearly (r = 0.99) during mechanical manipulation of MAP. EVP also correlated well with OVP (r = 0.9). Resistance calculations based on choroidal and ciliary blood flows and the pressure gradients indicate active adjustment of arterial resistance and passive changes in venous resistance in response to changing MAP in both circulations. The rabbit orbital venous sinus permits continuous measurements of OVP. The present findings show that OVP is not static and suggest that OVP may play an important role in IOP homeostasis and ocular hemodynamics.
- 1 December 2002
- Vol. 43 (12) , 3728-34
A rabbit model to study orbital venous pressure, intraocular pressure, and ocular hemodynamics simultaneously.
To measure orbital venous pressure (OVP) and determine the effects of changes in mean arterial pressure (MAP) on OVP, intraocular pressure (IOP), episcleral venous pressure (EVP), and ciliary and choroidal blood flows. The experiments were performed in anesthetized rabbits. In all animals, MAP, IOP, and OVP were measured by direct cannulation of the central ear artery, the vitreous, and the orbital venous sinus, respectively. Laser Doppler flowmetry was used to measure choroidal blood flow in one group, and ciliary blood flow in a second group. A servonull micropressure system was used to measure EVP in a third group. The protocol for all three groups entailed varying MAP mechanically with occluders on the aorta and vena cava. The OVP and IOP relationship correlated linearly (r = 0.99) during mechanical manipulation of MAP. EVP also correlated well with OVP (r = 0.9). Resistance calculations based on choroidal and ciliary blood flows and the pressure gradients indicate active adjustment of arterial resistance and passive changes in venous resistance in response to changing MAP in both circulations. The rabbit orbital venous sinus permits continuous measurements of OVP. The present findings show that OVP is not static and suggest that OVP may play an important role in IOP homeostasis and ocular hemodynamics.
- 1 August 2002
- Vol. 43 (8) , 2697-703
Effects of dopamine on ciliary blood flow, aqueous production, and intraocular pressure in rabbits.
Dopamine is a known modulator of cardiovascular function and intraocular pressure (IOP). In this study, the authors investigate the dose-dependent effects of dopamine on IOP, ciliary hemodynamics, and aqueous production in anesthetized rabbits to test the hypothesis that aqueous production becomes blood-flow-dependent if ciliary perfusion declines below some unknown critical level. Two protocols were performed. In the first protocol, mean arterial pressure (MAP) and IOP were measured by direct cannulation, and ciliary blood flow was measured transsclerally by laser Doppler flowmetry, while MAP was varied mechanically over a wide range before and during intravenous dopamine infusion (40 microg/min, n = 8; 80 microg/min, n = 10; 600 microg/min, n = 7; 1800 microg/min, n = 5). In the second protocol, MAP and IOP were measured by direct cannulation, and aqueous flow was measured by fluorophotometry, before and during intravenous dopamine infusion (40 microg/min, n = 8; 600 microg/min, n = 11). The low infusion rate shifted the ciliary pressure flow curves upward and increased aqueous production (40 microg/min), whereas the higher infusion rates shifted the pressure flow curves downward (600 and 1800 microg/min) and decreased aqueous production (600 microg/min). All infusion rates decreased IOP. Dopamine causes dose-dependent, parallel changes in ciliary blood flow and aqueous production, with ciliary vasodilation and secretory stimulation at the lowest infusion rate and vasoconstriction and secretory inhibition at higher infusion rates. Dopamine also significantly lowers IOP.
- 1 August 2002
- Vol. 43 (8) , 2697-703
Effects of dopamine on ciliary blood flow, aqueous production, and intraocular pressure in rabbits.
Dopamine is a known modulator of cardiovascular function and intraocular pressure (IOP). In this study, the authors investigate the dose-dependent effects of dopamine on IOP, ciliary hemodynamics, and aqueous production in anesthetized rabbits to test the hypothesis that aqueous production becomes blood-flow-dependent if ciliary perfusion declines below some unknown critical level. Two protocols were performed. In the first protocol, mean arterial pressure (MAP) and IOP were measured by direct cannulation, and ciliary blood flow was measured transsclerally by laser Doppler flowmetry, while MAP was varied mechanically over a wide range before and during intravenous dopamine infusion (40 microg/min, n = 8; 80 microg/min, n = 10; 600 microg/min, n = 7; 1800 microg/min, n = 5). In the second protocol, MAP and IOP were measured by direct cannulation, and aqueous flow was measured by fluorophotometry, before and during intravenous dopamine infusion (40 microg/min, n = 8; 600 microg/min, n = 11). The low infusion rate shifted the ciliary pressure flow curves upward and increased aqueous production (40 microg/min), whereas the higher infusion rates shifted the pressure flow curves downward (600 and 1800 microg/min) and decreased aqueous production (600 microg/min). All infusion rates decreased IOP. Dopamine causes dose-dependent, parallel changes in ciliary blood flow and aqueous production, with ciliary vasodilation and secretory stimulation at the lowest infusion rate and vasoconstriction and secretory inhibition at higher infusion rates. Dopamine also significantly lowers IOP.
- 1 January 2000
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 95 (1) , 47-53
Computer-controlled impalement of cells in retinal wholemounts visualized by infrared CCD imaging on an inverted microscope
- 1 January 2000
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 95 (1) , 47-53
Computer-controlled impalement of cells in retinal wholemounts visualized by infrared CCD imaging on an inverted microscope