P.G.G. Slaats
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
P.G.G. Slaats has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- H. Brink
Kiwa Water Research, P.O. Box 1072, 3430 BB Nieuwegein, The Netherlands
3 shared publications - G.A.M. Mesman
Kiwa Water Research, PO Box 1072, 3430 BB Nieuwegein, The Netherlands
1 shared publication - L.P.M. Rosenthal
PWN Noord-Holland, PO Box 2113, 1990 AC Velserbroek, The Netherlands
1 shared publication - M.W.M. van Eekeren
Kiwa Water Research, P.O. Box 1072, 3430 BB Nieuwegein, The Netherlands
1 shared publication - T.J.J. van der Hoven
Kiwa N.V. Research and Consultancy, PO Box 1072, 3430 BB Nieuwegein, The Netherlands;
1 shared publication
Latest Publications
- 1 January 2004
- Published by IWA Publishing in Water Science & Technology
- Vol. 49 (2) , 33-39
Tools to monitor corrosion of cement-containing water mains
Approximately 40,000 km of the drinking water network in The Netherlands consists of asbestos cement water pipes. The number of fractures in these pipes has increased greatly in recent years. This is due to corrosion of the asbestos cement (AC) which affects the condition of the pipe. Every time a fracture occurs, the question is raised of whether the pipe in question has to be replaced or repaired. A relatively simple destructive technique and non-destructive tests are used on a large scale to assess the condition of the AC pipes in use. Not only is corrosion detrimental to the pipes themselves, it also influences the water quality. Corrosion of the inner walls of cement-containing pipes involves the leaching of hydroxides. This causes pH changes resulting in scaling in water mains and domestic installations. Monitoring techniques have been developed to determine the effects of leaching on water quality. The large-scale use of the relatively simple techniques at water companies increases insight into the condition of the drinking water network, the life expectancy of the pipes and the effects of corrosion on the water quality. Applying these techniques enables those involved to make decisions on pipe replacement and to provide solutions for reducing the effects of leaching.
- 1 January 2004
- Published by IWA Publishing in Water Science & Technology
- Vol. 49 (2) , 33-39
Tools to monitor corrosion of cement-containing water mains
Approximately 40,000 km of the drinking water network in The Netherlands consists of asbestos cement water pipes. The number of fractures in these pipes has increased greatly in recent years. This is due to corrosion of the asbestos cement (AC) which affects the condition of the pipe. Every time a fracture occurs, the question is raised of whether the pipe in question has to be replaced or repaired. A relatively simple destructive technique and non-destructive tests are used on a large scale to assess the condition of the AC pipes in use. Not only is corrosion detrimental to the pipes themselves, it also influences the water quality. Corrosion of the inner walls of cement-containing pipes involves the leaching of hydroxides. This causes pH changes resulting in scaling in water mains and domestic installations. Monitoring techniques have been developed to determine the effects of leaching on water quality. The large-scale use of the relatively simple techniques at water companies increases insight into the condition of the drinking water network, the life expectancy of the pipes and the effects of corrosion on the water quality. Applying these techniques enables those involved to make decisions on pipe replacement and to provide solutions for reducing the effects of leaching.
- 1 January 2004
- Published by IWA Publishing in Water Science & Technology
- Vol. 49 (2) , 129-136
Scaling in domestic heating equipment: getting to know a complex phenomenon
Excessive scaling is one of the main nuisances in relation to the use of drinking water. Ever more water companies try to minimise scaling. Although scaling is an old problem, prediction of scaling has been proven to be very tricky. Traditionally, the (Langelier) Saturation Index is used to evaluate scaling properties of drinking water. From experience it is well known that this parameter is not suitable for proper prediction. New parameters have been developed and standardised for scaling prediction, namely the Calcium Carbonate Precipitation Potential, calculated at a temperature of 90°C (CCPP90); the Saturation Index, also calculated at a temperature of 90°C (SI90); the Nucleation Index (NI) and the Measured Calcium Carbonate Precipitation (MCCP). These parameters are currently successfully used in The Netherlands. The development of new parameters to predict scaling in domestic heating equipment has resulted in a better understanding of processes involved. Even now unexpected and at first sight contradictory results are obtained frequently. With the use of the developed measuring techniques, solutions may be found to combat excessive scaling.
- 1 January 2004
- Published by IWA Publishing in Water Science & Technology
- Vol. 49 (2) , 129-136
Scaling in domestic heating equipment: getting to know a complex phenomenon
Excessive scaling is one of the main nuisances in relation to the use of drinking water. Ever more water companies try to minimise scaling. Although scaling is an old problem, prediction of scaling has been proven to be very tricky. Traditionally, the (Langelier) Saturation Index is used to evaluate scaling properties of drinking water. From experience it is well known that this parameter is not suitable for proper prediction. New parameters have been developed and standardised for scaling prediction, namely the Calcium Carbonate Precipitation Potential, calculated at a temperature of 90°C (CCPP90); the Saturation Index, also calculated at a temperature of 90°C (SI90); the Nucleation Index (NI) and the Measured Calcium Carbonate Precipitation (MCCP). These parameters are currently successfully used in The Netherlands. The development of new parameters to predict scaling in domestic heating equipment has resulted in a better understanding of processes involved. Even now unexpected and at first sight contradictory results are obtained frequently. With the use of the developed measuring techniques, solutions may be found to combat excessive scaling.
- 1 June 2001
- Published by IWA Publishing in Water Supply
- Vol. 1 (3) , 75-82
Copper corrosion control in the Netherlands
Copper is the most commonly used material for pipes in domestic installations in the Netherlands. Depending on the composition of the water the copper pipes can add a significant amount of copper to drinking water. In the new European Drinking Water Directive (98/83/EC) the parametric value for copper in drinking water is decreased from 3 to 2 mg/l. The new directive also stipulates that copper levels should be determined on the basis of a sample ‘taken at the consumers' tap’ representative of the weekly average intake by humans. Harmonisation of monitoring protocols for copper in the European member states is necessary. In the Netherlands about 45% of the drinking water is already softened or de-acidified in order to decrease copper concentrations in drinking water. In the Netherlands two new treatment techniques have been studied for their impact on copper release; these are Reverse Osmosis (RO) and the addition of inhibitors. Copper pipe rig tests have shown that RO treatment decreases copper release. Split treatment of water with RO reduces copper solubility of drinking water through a decrease in both total inorganic carbon (TIC) and sulphate level. Remarkable was the relatively small decrease in copper release after split treatment with RO, compared to previous experiences in the Netherlands, suggesting an effect of natural organic matter. A new promising technique in the Netherlands is the addition of the inhibitor carbonate-activated silicate. At the test sites, the reduction in copper solubility due to the use of carbonate-activated silicate was 15 to 35%.
- 1 June 2001
- Published by IWA Publishing in Water Supply
- Vol. 1 (3) , 75-82
Copper corrosion control in the Netherlands
Copper is the most commonly used material for pipes in domestic installations in the Netherlands. Depending on the composition of the water the copper pipes can add a significant amount of copper to drinking water. In the new European Drinking Water Directive (98/83/EC) the parametric value for copper in drinking water is decreased from 3 to 2 mg/l. The new directive also stipulates that copper levels should be determined on the basis of a sample ‘taken at the consumers' tap’ representative of the weekly average intake by humans. Harmonisation of monitoring protocols for copper in the European member states is necessary. In the Netherlands about 45% of the drinking water is already softened or de-acidified in order to decrease copper concentrations in drinking water. In the Netherlands two new treatment techniques have been studied for their impact on copper release; these are Reverse Osmosis (RO) and the addition of inhibitors. Copper pipe rig tests have shown that RO treatment decreases copper release. Split treatment of water with RO reduces copper solubility of drinking water through a decrease in both total inorganic carbon (TIC) and sulphate level. Remarkable was the relatively small decrease in copper release after split treatment with RO, compared to previous experiences in the Netherlands, suggesting an effect of natural organic matter. A new promising technique in the Netherlands is the addition of the inhibitor carbonate-activated silicate. At the test sites, the reduction in copper solubility due to the use of carbonate-activated silicate was 15 to 35%.