Andrew Porteous
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrew Porteous has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- James Murray
North Bristol NHS Trust, Bristol BS10 5NB, UK
3 shared publications - Andrew James Price
Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK
2 shared publications - James Robinson
North Bristol NHS Trust, Bristol, UK
2 shared publications - Jonathan Phillips
Royal Devon University Healthcare NHS Foundation Trust, Exeter, UK; University of Exeter, Exeter, UK
2 shared publications - Abtin Alvand
Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS) University of Oxford Oxford UK
1 shared publication - Alberto Belluati
Orthopaedic and Trauma Department, Hospital Santa Maria delle Croci, Ravenna, Italy
1 shared publication
Latest Publications
- Open Access
- 30 April 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (2)
Reduced workload demand with handheld robotic‐assisted revision knee arthroplasty: A multi‐centre NASA Task Load Index analysis
Purpose: Revision total knee arthroplasty is a complex and technically demanding procedure, with an increasing global incidence. This complexity heightens the cognitive and physical demands of surgical teams, contributing to elevated burnout, musculoskeletal injuries and psychological stress. This European wide multi‐centre observational evaluation assessed the impact of a handheld robotic‐assisted surgical system on intra‐operative workload using the NASA Task Load Index instrument to compare robotic‐assisted and manual instrumentation approaches during revision knee arthroplasty. Methods: Data were collected from 212 surveys following 100 revision knee arthroplasty procedures, capturing subjective workload measures across six NASA Task Load Index domains from surgeons and peri‐operative theatre staff. Results: The results demonstrated a significant reduction in the overall workload with robotic‐assistance compared with manual instrumentation (median overall workload score 0.0 vs. 8.5 respectively, p = 0.0003). Domain‐specific analyses revealed significantly lower mental demand, physical demand and effort in the robotic‐assisted group without compromising perceived surgical performance, temporal demand, or frustration. A subgroup analysis of the lead surgeons showed consistent perceived workload reductions consistent with the overall findings. These results suggest that the handheld robotic‐assisted surgical system may mitigate cognitive and physical strain during complex revision knee arthroplasty procedures. Conclusions: This evaluation underscores the potential of robotic‐assisted technology to enhance surgical ergonomics, reduce surgeon fatigue and improve well‐being, which may translate into sustained surgical performance. Future work should incorporate objective ergonomic measures, expand participant roles and explore long‐term impacts on clinical outcomes and staff welfare. Level of Evidence: Level II.
- 30 April 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (2)
Open AccessReduced workload demand with handheld robotic‐assisted revision knee arthroplasty: A multi‐centre NASA Task Load Index analysis
Purpose: Revision total knee arthroplasty is a complex and technically demanding procedure, with an increasing global incidence. This complexity heightens the cognitive and physical demands of surgical teams, contributing to elevated burnout, musculoskeletal injuries and psychological stress. This European wide multi‐centre observational evaluation assessed the impact of a handheld robotic‐assisted surgical system on intra‐operative workload using the NASA Task Load Index instrument to compare robotic‐assisted and manual instrumentation approaches during revision knee arthroplasty. Methods: Data were collected from 212 surveys following 100 revision knee arthroplasty procedures, capturing subjective workload measures across six NASA Task Load Index domains from surgeons and peri‐operative theatre staff. Results: The results demonstrated a significant reduction in the overall workload with robotic‐assistance compared with manual instrumentation (median overall workload score 0.0 vs. 8.5 respectively, p = 0.0003). Domain‐specific analyses revealed significantly lower mental demand, physical demand and effort in the robotic‐assisted group without compromising perceived surgical performance, temporal demand, or frustration. A subgroup analysis of the lead surgeons showed consistent perceived workload reductions consistent with the overall findings. These results suggest that the handheld robotic‐assisted surgical system may mitigate cognitive and physical strain during complex revision knee arthroplasty procedures. Conclusions: This evaluation underscores the potential of robotic‐assisted technology to enhance surgical ergonomics, reduce surgeon fatigue and improve well‐being, which may translate into sustained surgical performance. Future work should incorporate objective ergonomic measures, expand participant roles and explore long‐term impacts on clinical outcomes and staff welfare. Level of Evidence: Level II.
- Open Access
- 22 January 2021
- Published by Springer Nature in Cureus
- Vol. 13 (1)
Use of a Novel Variable Power Radiofrequency Ablation System Specific for Knee Chondroplasty: Surgical Experience and Two-Year Patient Results
Introduction Although stabilisation of knee cartilage lesions (chondroplasty) may be performed with an arthroscopic shaver, more recently, radiofrequency (RF) ablation has gained in popularity. However, their remain some concerns about the avoidance of thermal injury, chondrolysis, and osteonecrosis with the use of RF devices. Methods We reviewed the outcomes of 85 knee chondroplasties performed with a new RF ablation wand designed for knee chondroplasty. Lesion details and Chondropaenia Severity Score (CSS) were recorded for each patient. We evaluated the occurrence of adverse outcomes, post-operative complications, and the need for further surgery. Post-operative outcomes scores (Oxford Knee Score [OKS], Knee injury and Osteoarthritis Outcome Score [KOOS], and International Knee Documentation Committee [IKDC] subjective knee outcome) were recorded at a minimum of one-year follow-up. Results At the final mean follow-up of 27.5 months (range: 12-46.6 months), 12 (14%) knees had undergone or were listed for further surgery. Four patients had corticosteroid injections for ongoing pain at a median 7.5 months (range: 5-20 months) post-operatively. There were no observed re-operations considered to be caused by complications related to thermal injury. Of the six patients listed for or undergoing knee arthroplasty, five (83%) had grade 4 lesions found at the arthroscopic chondroplasty. A negative correlation was noted between CCS, and post-operative IKDC subjective score (R=-0.35), KOOS Sports (R=-0.39), and KOOS QoL (R=-0.36). Conclusions We found that RF chondroplasty appeared safe, and there were no concerns with regard to thermal injury. Functional outcome appeared to be related to the quality of chondral and meniscal tissue throughout all knee compartments, with better results for isolated grade 2 and 3 cartilage lesions.
- 22 January 2021
- Published by Springer Nature in Cureus
- Vol. 13 (1)
Open AccessUse of a Novel Variable Power Radiofrequency Ablation System Specific for Knee Chondroplasty: Surgical Experience and Two-Year Patient Results
Introduction Although stabilisation of knee cartilage lesions (chondroplasty) may be performed with an arthroscopic shaver, more recently, radiofrequency (RF) ablation has gained in popularity. However, their remain some concerns about the avoidance of thermal injury, chondrolysis, and osteonecrosis with the use of RF devices. Methods We reviewed the outcomes of 85 knee chondroplasties performed with a new RF ablation wand designed for knee chondroplasty. Lesion details and Chondropaenia Severity Score (CSS) were recorded for each patient. We evaluated the occurrence of adverse outcomes, post-operative complications, and the need for further surgery. Post-operative outcomes scores (Oxford Knee Score [OKS], Knee injury and Osteoarthritis Outcome Score [KOOS], and International Knee Documentation Committee [IKDC] subjective knee outcome) were recorded at a minimum of one-year follow-up. Results At the final mean follow-up of 27.5 months (range: 12-46.6 months), 12 (14%) knees had undergone or were listed for further surgery. Four patients had corticosteroid injections for ongoing pain at a median 7.5 months (range: 5-20 months) post-operatively. There were no observed re-operations considered to be caused by complications related to thermal injury. Of the six patients listed for or undergoing knee arthroplasty, five (83%) had grade 4 lesions found at the arthroscopic chondroplasty. A negative correlation was noted between CCS, and post-operative IKDC subjective score (R=-0.35), KOOS Sports (R=-0.39), and KOOS QoL (R=-0.36). Conclusions We found that RF chondroplasty appeared safe, and there were no concerns with regard to thermal injury. Functional outcome appeared to be related to the quality of chondral and meniscal tissue throughout all knee compartments, with better results for isolated grade 2 and 3 cartilage lesions.