CBC. Boeri

C. Boeri

*This is an algorithmically generated author record based on publicly available information.

C. Boeri has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • 29 Faut-il des radiographies standard pour tout traumatisme isolé du genou ? Une étude prospective

    by C. Boéri, J.-Y. Jenny, H. El Amrani, J.-C. Dosch, M. Dupuis, A. Moussaoui, F. Mairot

    • 1 April 2003
      • Vol. 89  (2) , 163-6

    [Total hip replacement prosthesis infected by Mycobacterium tuberculous].

    by C Boéri, J Gaudias, J-Y Jenny

    We examined the diagnostic and therapeutic approaches used for two patients with loosened total hip prostheses who developed Mycobacterium tuberculosis infection. Revision total hip arthroplasty (THA) was performed in one patient. The prosthesis was left in situ in the second patient due to lack of sufficient bone stock. Medical treatment was given. The diagnosis was established on direct examination of bacteriological samples and culture on specific media. Polymerase chain reaction identified the Mycobacterium tuberculosis complex. Non-specific granulomas were observed on the histology sections. For us, management of overt tuberculosis involving a THA depends on the quality of the fixation. If the prosthesis remains stable, medical treatment can be sufficient. If the prosthesis loosens, definitive ablation must be considered with possible revision THA later. Exceptionally, a loosened implant may be left in situ if the remaining bone stock is insufficient. Minimal duration of anti-tuberulosis treatment is six months.


    • 1 November 2001
      • Vol. 87  (7) , 645-52

    [Computer-assisted implantation of a total knee arthroplasty: a case-controlled study in comparison with classical instrumentation].

    by J Y Jenny, C Boeri

    The quality of total knee arthroplasty (TKA) implantation is an essential factor determining long-term outcome. Computer-assisted implantation could improve quality compared with conventional manual instrumentation. We studied the radiographic quality of TKA implantation in 100 patients with primary degenerative knee disease who underwent a computer-assisted procedure guided by an informatic navigation system without imagery (group A) or a conventional manual procedure (group B). The two groups were matched for age, sex, initial frontal mechanical tibiofemoral angle and severity of the degenerative lesions. Postoperative telemetry was used in accordance with the Knee Society guidelines to measure the frontal mechanical tibiofemoral angle and the frontal and sagittal tilt of the tibial and femoral components. The number of optimal implantations for the five measured criteria was chosen as the main study criterion. The two groups were compared using the chi-squared test with statistical significance set at 5% and power at 80%. Globally, implantation of the prosthesis was considered to be optimal in 33 patients in group A and in 15 in group B (p<0.001). Mean angles were not different between the two groups, except for sagittal tilt of the femoral piece. The frontal mechanical tibiofemoral angle was considered optimal in 47 patients in group A and in 39 in group B (p<0.05). A significant improvement in the quality of the implantation was also found in group A for frontal tilt of the femoral piece (p=0.05), frontal tilt of the tibial piece (p<0.05) and sagittal tilt of the tibial piece (p<0.001). No particular peroperative difficulty or complication was related to the navigation system. The navigation system allowed a significant improvement in the quality of implantation of TKA compared with conventional instrumentation controlled by the surgeon's hand and eye. Only minimal changes in the operative technique are necessary and standard preoperative investigations remain unchanged. Long-term survival of prostheses implanted with this system could thus be improved compared with manually implanted TKA. The system used here does not involve preoperative imaging and allows a precision to the order of 1 degree for angles and 1 mm for lengths.


  • Navigiert implantierte Knietotalendoprothesen - Eine Vergleichsstudie zum konventionellen Instrumentarium

    by J.-Y. Jenny, C. Boeri

    Fragestellung: Das Ziel von Navigationssystemen ist, die Qualität der Prothesenimplantation im Vergleich zu konventionellen, manuellen Instrumentarien zu verbessern. Methode: Die Autoren haben 40 Knietotalendoprothesen mit einem optischen Navigationssystem (Orthopilot®, AESCULAP, Tuttlingen) implantiert (Gruppe A). Eine statistisch-gepaarte Vergleichsgruppe (Gruppe B) von ebenfalls 40 Knietotelendoprothesen des selben Typs (Search® Prothese, AESCULAP, Tuttlingen) wurde mit konventionellem manuellen Instrumentarium versorgt. Die Qualität der Implantation wurde röntgenologisch auf AP und lateralen Achsenaufnahmen ermittelt. Ergebnisse: Ein angestrebter mechanischer femorotibialer Winkel (3° Valgus bis 3° Varus) wurde bei 33 Fällen der Gruppe A und 31 Fällen der Gruppe B erreicht (p > 0,05). Bei der frontalen und sagittalen Orientierung der femoralen und tibialen Komponenten konnten relevante Unterschiede in Richtung einer präzisen Implantation in der Gruppe A beobachtet werden. Insgesamt konnten bei 26 Patienten der Gruppe A und 12 Patienten der Gruppe B die angestrebten Winkel in allen Ebenen erreicht werden (p < 0,01). Schlussfolgerung: Das verwendete Navigationssystem erlaubt eine signifikant verbesserte Implantationsqualität von Knietotalendoprothesen im Vergleich zur konventionellen Implantationstechnik. Dadurch könnten sich auch die Früh- und Langzeitergebnisse verbessern. Objective:A navigation system should improve the quality of a total knee prosthesis implantation in comparison to the classical, surgeon-controlled operative technique. Methods: The authors have implanted 40 knee total prostheses with an optical infrared navigation system (Orthopilot® AESCULAP, Tuttlingen - group A). The quality of implantation was studied on postoperative long leg AP and lateral X-rays, and compared to a control group of 40 computer-paired total knee prostheses o the same model (Search® Prosthesis, AESCULAP, Tuttlingen) implanted with a classical, surgeon-controlled technique (group B). Results: An optimal mechanical femorotibial angle (3° valgus to 3° varus) was obtained by 33 cases in group A and 31 cases in group B (p > 0,05). Better results were seen for the coronal and sagittal orientation of both tibial and femoral components in group A. Globally, 26 cases of the group A and 12 cases of the group B were implanted in an optimal manner for all studied criteria (p < 0.01). Conclusions: The used navigation system allows a signifikant improvement of the quality of implantation of a knee total prosthesis in comparison to a classical, surgeon-controlled instrumentation. Long-term outcome could be consequently improved.