Run Zhang Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Run Zhang Shi has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Guolin Zhou
Department of Medicine, University of Chicago, 5841 S. Maryland Avenue, MC2115, Chicago, Illinois 60637, USA
1 shared publication Janet D Rowley
Department of Medicine, University of Chicago, Chicago, IL 60637
1 shared publication- Jianjun Chen
Department of Medicine, University of Chicago, Chicago, IL 60637
1 shared publication Joseph M Morrissey
Motorola Corporate Laboratories, Ft. Lauderdale, FL 33322
1 shared publication- Miao Sun
Department of Medicine, University of Chicago, 5841 S, Maryland Avenue, MC2115, Chicago, Illinois 60637, USA
1 shared publication - San Ming Wang
Department of Medicine, University of Chicago, 5841 S. Maryland Avenue, MC2115, Chicago, Illinois 60637, USA
1 shared publication
Latest Publications
- Open Access
- 5 January 2004
- Published by Springer Nature in BMC Genomics
- Vol. 5 (1) , 1
SAGE is far more sensitive than EST for detecting low-abundance transcripts
Isolation of low-abundance transcripts expressed in a genome remains a serious challenge in transcriptome studies. The sensitivity of the methods used for analysis has a direct impact on the efficiency of the detection. We compared the EST method and the SAGE method to determine which one is more sensitive and to what extent the sensitivity is great for the detection of low-abundance transcripts. Using the same low-abundance transcripts detected by both methods as the targeted sequences, we observed that the SAGE method is 26 times more sensitive than the EST method for the detection of low-abundance transcripts. The SAGE method is more efficient than the EST method in detecting the low-abundance transcripts.
- 5 January 2004
- Published by Springer Nature in BMC Genomics
- Vol. 5 (1) , 1
Open AccessSAGE is far more sensitive than EST for detecting low-abundance transcripts
Isolation of low-abundance transcripts expressed in a genome remains a serious challenge in transcriptome studies. The sensitivity of the methods used for analysis has a direct impact on the efficiency of the detection. We compared the EST method and the SAGE method to determine which one is more sensitive and to what extent the sensitivity is great for the detection of low-abundance transcripts. Using the same low-abundance transcripts detected by both methods as the targeted sequences, we observed that the SAGE method is 26 times more sensitive than the EST method for the detection of low-abundance transcripts. The SAGE method is more efficient than the EST method in detecting the low-abundance transcripts.
- 1 July 2003
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 49 (7) , 1066-1073
Screening and Quantification of Multiple Chromosome Translocations in Human Leukemia
Background: Characterization of fusion gene transcripts in leukemia that result from chromosome translocations provides valuable information regarding appropriate treatment and prognosis. However, screening for multiple fusion gene transcripts is difficult with conventional PCR and state-of-the-art real-time PCR and high-density microarrays. Methods: We developed a multiplex reverse transcription-PCR (RT-PCR) assay for screening and quantification of fusion gene transcripts in human leukemia cells. Chimeric primers were used that contained gene-specific and universal sequences. PCR amplification of fusion and control gene transcripts was achieved with use of an excess of universal primers to allow the ratio of abundance of fusion gene to endogenous or exogenous controls to be maintained throughout PCR. Multiplex RT-PCR products analyzed by an ABI 310 Genetic Analyzer were consistent with those of duplex RT-PCR (single analytical sample plus control). In addition, multiplex RT-PCR results were analyzed by an assay using an oligonucleotide microarray that contained probes for the splice-junction sequences of various fusion transcripts. Results: The multiplex RT-PCR assay enabled screening of >10 different fusion gene transcripts in a single reaction. RT-PCR followed by analysis with the ABI Prism 310 Genetic Analyzer consistently detected 1 fusion-transcript-carrying leukemia cell in 100–10 000 cells. The assay covered a 1000-fold range. Preliminary results indicate that multiplex RT-PCR products can also be analyzed by hybridization-based microarray assay. Conclusions: The multiplex RT-PCR analyzed by either ABI Prism 310 Genetic Analyzer or microarray provides a sensitive and specific assay for screening of multiple fusion transcripts in leukemia, with the latter an assay that is adaptable to a high-throughput system for clinical screening.
- 1 July 2003
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 49 (7) , 1066-1073
Screening and Quantification of Multiple Chromosome Translocations in Human Leukemia
Background: Characterization of fusion gene transcripts in leukemia that result from chromosome translocations provides valuable information regarding appropriate treatment and prognosis. However, screening for multiple fusion gene transcripts is difficult with conventional PCR and state-of-the-art real-time PCR and high-density microarrays. Methods: We developed a multiplex reverse transcription-PCR (RT-PCR) assay for screening and quantification of fusion gene transcripts in human leukemia cells. Chimeric primers were used that contained gene-specific and universal sequences. PCR amplification of fusion and control gene transcripts was achieved with use of an excess of universal primers to allow the ratio of abundance of fusion gene to endogenous or exogenous controls to be maintained throughout PCR. Multiplex RT-PCR products analyzed by an ABI 310 Genetic Analyzer were consistent with those of duplex RT-PCR (single analytical sample plus control). In addition, multiplex RT-PCR results were analyzed by an assay using an oligonucleotide microarray that contained probes for the splice-junction sequences of various fusion transcripts. Results: The multiplex RT-PCR assay enabled screening of >10 different fusion gene transcripts in a single reaction. RT-PCR followed by analysis with the ABI Prism 310 Genetic Analyzer consistently detected 1 fusion-transcript-carrying leukemia cell in 100–10 000 cells. The assay covered a 1000-fold range. Preliminary results indicate that multiplex RT-PCR products can also be analyzed by hybridization-based microarray assay. Conclusions: The multiplex RT-PCR analyzed by either ABI Prism 310 Genetic Analyzer or microarray provides a sensitive and specific assay for screening of multiple fusion transcripts in leukemia, with the latter an assay that is adaptable to a high-throughput system for clinical screening.